This Annex defines a correspondence between the SNOMED codes used in context groups for Anatomic Region Sequence (0008,2218) and Body Part Examined (0018,0015), as well as providing a list of the Defined Terms for Body Part Examined (0018,0015), for human use in Table L-1 and for animal use in Table L-2.
Table L-1. Corresponding SNOMED Terms for Human Use
SNOMED Code Value |
Code Meaning |
Body Part Examined |
---|---|---|
T-D4000 |
Abdomen |
ABDOMEN |
R-FAB57 |
Abdomen and Pelvis |
ABDOMENPELVIS |
T-42500 |
Abdominal aorta |
|
T-41070 |
Abdominal aorta and its branches |
|
T-15420 |
Acromioclavicular joint |
|
T-B3000 |
Adrenal gland |
ADRENAL |
T-15750 |
Ankle joint |
ANKLE |
T-48503 |
Anomalous pulmonary vein |
|
T-49215 |
Antecubital vein |
|
T-48440 |
Anterior cardiac vein |
|
T-45530 |
Anterior communicating artery |
|
T-45730 |
Anterior spinal artery |
|
T-47700 |
Anterior tibial artery |
|
T-59490 |
Anus, rectum and sigmoid colon |
|
T-42000 |
Aorta |
AORTA |
T-42300 |
Aortic arch |
|
D3-81922 |
Aortic fistula |
|
T-32602 |
Apex of left ventricle |
|
T-280A0 |
Apex of Lung |
|
T-32502 |
Apex of right ventricle |
|
T-41000 |
Artery |
|
T-42100 |
Ascending aorta |
|
T-32100 |
Atrium |
|
T-D8100 |
Axilla |
AXILLA |
T-47100 |
Axillary Artery |
|
T-49110 |
Axillary vein |
|
T-48340 |
Azygos vein |
|
T-D2100 |
Back |
BACK |
A-00203 |
Baffle |
|
T-45800 |
Basilar artery |
|
T-60610 |
Bile duct |
|
T-74000 |
Bladder |
BLADDER |
T-DD123 |
Bladder and urethra |
|
T-D00AB |
Body conduit |
|
T-49424 |
Boyd's perforating vein |
|
T-47160 |
Brachial artery |
|
T-49350 |
Brachial vein |
|
T-A0100 |
Brain |
BRAIN |
T-04000 |
Breast |
BREAST |
T-D6500 |
Broad ligament |
|
T-26000 |
Bronchus |
BRONCHUS |
T-D1206 |
Buccal region of face |
|
T-D2600 |
Buttock |
BUTTOCK |
T-12770 |
Calcaneus |
CALCANEUS |
T-D9440 |
Calf of leg |
CALF |
T-72100 |
Calyx |
|
T-45010 |
Carotid Artery |
CAROTID |
T-49240 |
Cephalic vein |
|
T-A6000 |
Cerebellum |
CEREBELLUM |
T-45510 |
Cerebral artery |
|
T-11501 |
Cervical spine |
CSPINE |
T-D00F7 |
Cervico-thoracic spine |
CTSPINE |
T-83200 |
Cervix |
CERVIX |
T-D1206 |
Cheek |
CHEEK |
T-D3000 |
Chest |
CHEST |
R-FAB55 |
Chest and Abdomen |
CHESTABDOMEN |
R-FAB56 |
Chest, Abdomen and Pelvis |
CHESTABDPELVIS |
T-45526 |
Circle of Willis |
CIRCLEOFWILLIS |
T-12310 |
Clavicle |
CLAVICLE |
T-11BF0 |
Coccyx |
COCCYX |
T-59300 |
Colon |
COLON |
D4-31320 |
Common atrium |
|
T-45100 |
Common carotid artery |
|
T-46710 |
Common iliac artery |
|
T-48920 |
Common iliac vein |
|
D4-31120 |
Common ventricle |
|
D4-32504 |
Congenital coronary artery fistula to left atrium |
|
D4-32506 |
Congenital coronary artery fistula to left ventricle |
|
D4-32509 |
Congenital coronary artery fistula to right atrium |
|
D4-32510 |
Congenital coronary artery fistula to right ventricle |
|
D3-40208 |
Congenital pulmonary arteriovenous fistula |
|
T-AA200 |
Cornea |
CORNEA |
T-43000 |
Coronary artery |
CORONARYARTERY |
T-48410 |
Coronary sinus |
|
T-A0193 |
Cranial venous system |
|
T-42400 |
Descending aorta |
|
T-49429 |
Dodd's perforating vein |
|
T-58200 |
Duodenum |
DUODENUM |
T-AB000 |
Ear |
EAR |
T-15430 |
Elbow joint |
ELBOW |
T-41000 |
Endo-arterial |
|
T-32000 |
Endo-cardiac |
|
T-56000 |
Endo-esophageal |
|
T-21300 |
Endo-nasal |
|
T-23050 |
Endo-nasopharyngeal |
|
T-59600 |
Endo-rectal |
|
T-71000 |
Endo-renal |
|
T-73000 |
Endo-ureteric |
|
T-75000 |
Endo-urethral |
|
T-82000 |
Endo-vaginal |
|
T-40000 |
Endo-vascular |
|
T-48000 |
Endo-venous |
|
T-74250 |
Endo-vesical |
|
T-D0010 |
Entire body |
WHOLEBODY |
T-D4200 |
Epigastric region |
|
T-56000 |
Esophagus |
ESOPHAGUS |
T-DD163 |
Esophagus, stomach and duodenum |
|
T-AB200 |
External auditory canal |
|
T-45200 |
External carotid artery |
|
T-46910 |
External iliac artery |
|
T-48930 |
External iliac vein |
|
T-D0300 |
Extremity |
EXTREMITY |
T-AA000 |
Eye |
EYE |
T-AA810 |
Eyelid |
EYELID |
T-D1200 |
Face |
FACE |
T-45240 |
Facial artery |
|
T-11196 |
Facial bones |
|
T-47400 |
Femoral artery |
|
T-49410 |
Femoral vein |
|
T-12710 |
Femur |
FEMUR |
T-D8800 |
Finger |
FINGER |
T-D2310 |
Flank |
|
T-15200 |
Fontanel of skull |
|
T-D9700 |
Foot |
FOOT |
T-D8500 |
Forearm |
|
T-63000 |
Gallbladder |
GALLBLADDER |
T-48820 |
Gastric vein |
|
T-47490 |
Genicular artery |
|
T-D2600 |
Gluteal region |
|
T-48420 |
Great cardiac vein |
|
T-D8700 |
Hand |
HAND |
T-D1100 |
Head |
HEAD |
T-D1000 |
Head and Neck |
HEADNECK |
T-32000 |
Heart |
HEART |
T-46420 |
Hepatic artery |
|
T-48720 |
Hepatic vein |
|
T-15710 |
Hip joint |
HIP |
T-12410 |
Humerus |
HUMERUS |
T-4942A |
Hunterian perforating vein |
|
T-D4240 |
Hypogastric region |
|
T-D1212 |
Hypoglossal |
|
T-55300 |
Hypopharynx |
|
T-58600 |
Ileum |
ILEUM |
T-41040 |
Iliac arterial system |
|
T-46700 |
Iliac artery |
|
T-12340 |
Ilium |
ILIUM |
T-48470 |
Inferior cardiac vein |
|
T-48540 |
Inferior left pulmonary vein |
|
T-46520 |
Inferior mesenteric artery |
|
T-48520 |
Inferior right pulmonary vein |
|
T-48710 |
Inferior vena cava |
|
T-D7000 |
Inguinal region |
|
T-46010 |
Innominate artery |
|
T-48620 |
Innominate vein |
|
T-AB959 |
Internal Auditory Canal |
IAC |
T-45300 |
Internal carotid artery |
|
T-46740 |
Internal iliac artery |
|
T-48170 |
Internal jugular vein |
|
T-46200 |
Internal mammary artery |
|
T-D4010 |
Intra-abdominal |
|
G-A15A |
Intra-articular |
|
T-56000 |
Intra-esophageal |
|
T-D6221 |
Intra-pelvic |
|
T-D3000 |
Intra-thoracic |
|
T-D1400 |
Intracranial |
|
T-D1213 |
Jaw region |
JAW |
T-58400 |
Jejunum |
JEJUNUM |
T-15001 |
Joint |
|
D4-31052 |
Juxtaposed atrial appendage |
|
T-71000 |
Kidney |
KIDNEY |
T-D9200 |
Knee |
KNEE |
T-45410 |
Lacrimal artery |
|
T-45416 |
Lacrimal artery of right eye |
|
T-59000 |
Large intestine |
|
T-24100 |
Larynx |
LARYNX |
T-32300 |
Left atrium |
|
T-32310 |
Left auricular appendage |
|
T-47420 |
Left femoral artery |
|
T-D4211 |
Left hypochondriac region |
|
T-D7020 |
Left inguinal region |
|
T-D4140 |
Left lower quadrant of abdomen |
|
T-D2340 |
Left lumbar region |
|
T-44400 |
Left pulmonary artery |
|
T-D4130 |
Left upper quadrant of abdomen |
|
T-32600 |
Left ventricle |
|
T-32640 |
Left ventricle inflow |
|
D4-31022 |
Left ventricle outflow chamber |
|
T-32650 |
Left ventricle outflow tract |
|
T-45230 |
Lingual artery |
|
T-62000 |
Liver |
LIVER |
T-04003 |
Lower inner quadrant of breast |
|
T-D9400 |
Lower leg |
LEG |
T-04005 |
Lower outer quadrant of breast |
|
T-46960 |
Lumbar artery |
|
T-D2300 |
Lumbar region |
|
T-11503 |
Lumbar spine |
LSPINE |
T-D00F9 |
Lumbo-sacral spine |
LSSPINE |
T-40230 |
Lumen of blood vessel |
|
T-28000 |
Lung |
LUNG |
T-11180 |
Mandible |
JAW |
T-11133 |
Mastoid bone |
|
T-11170 |
Maxilla |
MAXILLA |
T-D3300 |
Mediastinum |
MEDIASTINUM |
T-46500 |
Mesenteric artery |
|
T-4884A |
Mesenteric vein |
|
T-51000 |
Mouth |
MOUTH |
T-11149 |
Nasal bone |
|
T-2300C |
Naso pharynx |
|
T-D1600 |
Neck |
NECK |
R-FAB52 |
Neck and Chest |
NECKCHEST |
R-FAB53 |
Neck, Chest and Abdomen |
NECKCHESTABDOMEN |
R-FAB54 |
Neck, Chest, Abdomen and Pelvis |
NECKCHESTABDPELV |
T-21000 |
Nose |
NOSE |
T-45250 |
Occipital artery |
|
T-48214 |
Occipital vein |
|
T-D4450 |
Omental bursa |
|
T-D4600 |
Omentum |
|
T-45400 |
Ophthalmic artery |
|
T-11102 |
Optic canal |
|
T-D14AE |
Orbital structure |
ORBIT |
T-87000 |
Ovary |
OVARY |
T-65000 |
Pancreas |
PANCREAS |
T-65010 |
Pancreatic duct |
|
T-65600 |
Pancreatic duct and bile duct systems |
|
T-22000 |
Paranasal sinus |
|
T-D3136 |
Parasternal |
|
T-B7000 |
Parathyroid |
|
T-61100 |
Parotid gland |
PAROTID |
T-12730 |
Patella |
PATELLA |
D4-32012 |
Patent ductus arteriosus |
|
T-D6000 |
Pelvis |
PELVIS |
R-FAB58 |
Pelvis and lower extremities |
|
T-91000 |
Penis |
PENIS |
T-D2700 |
Perineum |
|
T-47630 |
Peroneal artery |
|
T-55000 |
Pharynx |
PHARYNX |
T-20101 |
Pharynx and larynx |
|
T-47500 |
Popliteal artery |
|
T-D9310 |
Popliteal fossa |
|
T-48810 |
Portal vein |
|
T-45320 |
Posterior communicating artery |
|
T-49535 |
Posterior medial tributary |
|
T-47600 |
Posterior tibial artery |
|
T-F7001 |
Primitive aorta |
|
T-F7040 |
Primitive pulmonary artery |
|
T-9200B |
Prostate |
PROSTATE |
T-44000 |
Pulmonary artery |
|
D4-33142 |
Pulmonary artery conduit |
|
T-32190 |
Pulmonary chamber of cor triatriatum |
|
T-48581 |
Pulmonary vein |
|
D4-33512 |
Pulmonary vein confluence |
|
D4-33514 |
Pulmonary venous atrium |
|
T-47300 |
Radial artery |
|
T-59600 |
Rectum |
RECTUM |
T-46600 |
Renal artery |
|
T-72000 |
Renal pelvis |
|
T-48740 |
Renal vein |
|
T-D4900 |
Retroperitoneum |
|
T-11300 |
Rib |
RIB |
T-32200 |
Right atrium |
|
T-32210 |
Right auricular appendage |
|
T-47410 |
Right femoral artery |
|
T-D4212 |
Right hypochondriac region |
|
T-D7010 |
Right inguinal region |
|
T-D4120 |
Right lower quadrant of abdomen |
|
T-D2342 |
Right lumbar region |
|
T-44200 |
Right pulmonary artery |
|
T-D4110 |
Right upper quadrant of abdomen |
|
T-32500 |
Right ventricle |
|
T-32540 |
Right ventricle inflow |
|
D4-31032 |
Right ventricle outflow chamber |
|
T-32550 |
Right ventricle outflow tract |
|
T-15680 |
Sacroiliac joint |
|
T-11AD0 |
Sacrum |
SSPINE |
T-D930A |
Saphenofemoral junction |
|
T-49530 |
Saphenous vein |
|
T-D1160 |
Scalp |
SCALP |
T-12280 |
Scapula |
SCAPULA |
T-AA110 |
Sclera |
SCLERA |
T-98000 |
Scrotum |
SCROTUM |
T-D1460 |
Sella turcica |
|
T-12980 |
Sesamoid bones of foot |
|
T-D2220 |
Shoulder |
SHOULDER |
T-59470 |
Sigmoid colon |
|
T-11100 |
Skull |
SKULL |
T-58000 |
Small intestine |
|
T-A7010 |
Spinal cord |
|
T-D0146 |
Spine |
SPINE |
T-C3000 |
Spleen |
SPLEEN |
T-46460 |
Splenic artery |
|
T-48890 |
Splenic vein |
|
T-15610 |
Sternoclavicular joint |
|
T-11210 |
Sternum |
STERNUM |
T-57000 |
Stomach |
STOMACH |
T-46100 |
Subclavian artery |
|
T-48330 |
Subclavian vein |
|
T-D4210 |
Subcostal |
|
T-D1603 |
Submandibular area |
|
T-61300 |
Submandibular gland |
SUBMANDIBULAR |
T-D3213 |
Subxiphoid |
|
T-45270 |
Superficial temporal artery |
|
T-48530 |
Superior left pulmonary vein |
|
T-46510 |
Superior mesenteric artery |
|
T-48510 |
Superior right pulmonary vein |
|
T-45210 |
Superior thyroid artery |
|
T-48610 |
Superior vena cava |
|
T-D1620 |
Supraclavicular region of neck |
|
T-D4240 |
Suprapubic region |
|
T-11218 |
Suprasternal notch |
|
T-44007 |
Systemic collateral artery to lung |
|
D4-33516 |
Systemic venous atrium |
|
T-15770 |
Tarsal joint |
|
T-15290 |
Temporomandibular joint |
TMJ |
T-94000 |
Testis |
TESTIS |
T-D9100 |
Thigh |
THIGH |
T-42070 |
Thoracic aorta |
|
T-11502 |
Thoracic spine |
TSPINE |
T-D00F8 |
Thoraco-lumbar spine |
TLSPINE |
T-D3000 |
Thorax |
|
T-D8810 |
Thumb |
THUMB |
T-C8000 |
Thymus |
THYMUS |
T-B6000 |
Thyroid |
THYROID |
T-D9800 |
Toe |
TOE |
T-53000 |
Tongue |
TONGUE |
T-25000 |
Trachea |
TRACHEA |
T-DD006 |
Trachea and bronchus |
|
D4-31400 |
Truncus arteriosus communis |
|
T-46400 |
Truncus coeliacus |
|
T-47200 |
Ulnar artery |
|
T-F1810 |
Umbilical artery |
|
T-D4230 |
Umbilical region |
|
T-48817 |
Umbilical vein |
|
T-D8200 |
Upper arm |
ARM |
T-04002 |
Upper inner quadrant of breast |
|
T-04004 |
Upper outer quadrant of breast |
|
T-70010 |
Upper urinary tract |
|
T-73000 |
Ureter |
URETER |
T-75000 |
Urethra |
URETHRA |
T-83000 |
Uterus |
UTERUS |
T-88920 |
Uterus and fallopian tubes |
|
T-82000 |
Vagina |
VAGINA |
A-04140 |
Vascular graft |
|
T-48000 |
Vein |
|
T-48003 |
Venous network |
|
T-32400 |
Ventricle |
|
T-45700 |
Vertebral artery |
|
T-11011 |
Vertebral column and cranium |
|
T-81000 |
Vulva |
VULVA |
T-15460 |
Wrist joint |
WRIST |
T-11166 |
Zygoma |
ZYGOMA |
In prior versions of this table, different codes were used for some concepts; see PS3.16-2011.
Table L-2. Corresponding SNOMED Terms for Animals
SNOMED Code Value |
Code Meaning |
Body Part Examined |
T-D4000 |
Abdomen |
ABDOMEN |
T-D8030 |
All legs |
LEGS |
T-1531B |
Atlantal-axial joint |
ATLANTOAXIAL |
T-15311 |
Atlanto-occipital joint |
ATLANTOOCCIPITAL |
T-74000 |
Bladder |
BLADDER |
T-12771 |
Calcaneal tubercle |
|
T-D0788 |
Carpus |
CARPUS |
T-11501 |
Cervical spine |
CSPINE |
T-D00F7 |
Cervico-thoracic spine |
CTSPINE |
T-D3000 |
Chest |
CHEST |
R-FAB55 |
Chest and Abdomen |
CHESTABDOMEN |
T-11B02 |
Coccygeal vertrebrae |
TAIL |
T-59300 |
Colon |
COLON |
T-D0310 |
Digit |
DIGIT |
T-110A2 |
Distal phalanx |
DISTALPHALANX |
T-15430 |
Elbow joint |
ELBOW |
T-D0010 |
Entire body |
WHOLEBODY |
T-56000 |
Esophagus |
ESOPHAGUS |
T-12710 |
Femur |
FEMUR |
T-D8640 |
Fetlock of forelimb |
FOREFETLOCK |
T-D9540 |
Fetlock of hindlimb |
HINDFETLOCK |
T-D04F2 |
Forefoot |
FOREFOOT |
T-22200 |
Frontal sinus |
FRONTALSINUS |
T-D9713 |
Hindfoot |
HINDFOOT |
T-15710 |
Hip joint |
HIP |
T-12410 |
Humerus |
HUMERUS |
T-11503 |
Lumbar spine |
LSPINE |
T-D00F9 |
Lumbo-sacral spine |
LSSPINE |
T-11180 |
Mandible |
JAW |
T-54170 |
Mandibular dental arch |
|
T-540EE |
Mandibular incisor teeth |
|
T-54160 |
Maxillary dental arch |
|
T-540ED |
Maxillary incisor teeth |
|
T-1254D |
Metacarpus |
METACARPUS |
T-12847 |
Metatarsus |
METATARSUS |
T-22000 |
Nasal sinus |
|
T-12450 |
Navicular of forefoot |
FORENAVICULAR |
T-127EC |
Navicular of hindfoot |
HINDNAVICULAR |
T-D14AD |
Orbital region |
|
T-D8650 |
Pastern of forefoot |
FOREPASTERN |
T-D9550 |
Pastern of hindfoot |
HINDPASTERN |
T-12730 |
Patella |
PATELLA |
T-D6000 |
Pelvis |
PELVIS |
T-12403 |
Radius and ulna |
RADIUSULNA |
T-11AD0 |
Sacrum |
SSPINE |
T-D2220 |
Shoulder |
SHOULDER |
T-11100 |
Skull |
SKULL |
T-15728 |
Stiffle |
STIFLE |
T-11096 |
Tarsus |
TARSUS |
T-11502 |
Thoracic spine |
TSPINE |
T-D00F8 |
Thoraco-lumbar spine |
TLSPINE |
T-12701 |
Tibia and fibula |
TIBIAFIBULA |
T-50110 |
Upper gastro-intestinal tract |
UGITRACT |
T-75000 |
Urethra |
URETHRA |
T-70000 |
Urinary tract |
URINARYTRACT |
T-D8040 |
Wing |
WING |
In prior versions of this table, different codes were used for some concepts; see PS3.16-2011.