Table 10-16. Performed Procedure Step Summary Macro Attributes
Attribute Name |
Tag |
Type |
Attribute Description |
---|---|---|---|
Performed Procedure Step ID |
(0040,0253) |
3 |
User or equipment generated identifier of that part of a Procedure that has been carried out within this step. |
Performed Procedure Step Start Date |
(0040,0244) |
3 |
Date on which the Performed Procedure Step started. |
Performed Procedure Step Start Time |
(0040,0245) |
3 |
Time on which the Performed Procedure Step started. |
Performed Procedure Step End Date |
(0040,0250) |
3 |
Date on which the Performed Procedure Step ended. |
Performed Procedure Step End Time |
(0040,0251) |
3 |
Time at which the Performed Procedure Step ended. |
Performed Procedure Step Description |
(0040,0254) |
3 |
Institution-generated description or classification of the Procedure Step that was performed. |
Performed Protocol Code Sequence |
(0040,0260) |
3 |
Sequence describing the Protocol performed for this Procedure Step. One or more Items are permitted in this sequence. |
Context ID may be defined in the macro invocation. |
|||
>Protocol Context Sequence |
(0040,0440) |
3 |
Sequence that specifies the context for the Performed Protocol Code Sequence Item. One or more Items are permitted in this sequence. |
>>Include Table 10-2 “Content Item Macro Attributes Description” |
Context ID may be defined in the macro invocation. |
||
>>Content Item Modifier Sequence |
(0040,0441) |
3 |
Sequence that specifies modifiers for a Protocol Context Content Item. One or more Items are permitted in this sequence. See Section C.4.10.1. |
>>>Include Table 10-2 “Content Item Macro Attributes Description” |
Context ID may be defined in the macro invocation. |
||
Comments on the Performed Procedure Step |
(0040,0280) |
3 |
User-defined comments on the Performed Procedure Step. |