DICOM PS3.20 2020c - Imaging Reports using HL7 Clinical Document Architecture

9.8.5 Radiation Exposure and Protection Information

Template ID

1.2.840.10008.9.8

Name

Radiation Exposure and Protection Information

Effective Date

2015/03/24

Version Label

DICOM-20150324

Status

Active

Description

Contains information related to the radiation exposure and protection of the patient, as may be required by national or local legal requirements or standards.

Classification

CDA Section and Entry Level

Relationships

Included in 9.3 Imaging Procedure Description

Context

parent node

Open/Closed

Open

Revision History

DICOM-20150324: Initial version

Business Name

Nest Level

Element/​Attribute

Card

Elem/Attr Conf

Data Type

Value Conf

Value

Subsidiary Template

Radiation​Exposure

section

1..1

SHALL

>

template​Id

1..1

SHALL

II

>>@

@root

1..1

SHALL

UID

SHALL

1.2.840.10008.9.8

>

code

1..1

SHALL

CD

SHALL

(73569-6, LOINC, "Radiation exposure and protection information")

>

id

1..1

SHALL

II

Title

>

title

1..1

SHALL

ST

Text

>

text

1..1

SHALL

ED

9.1.1 Section Text 1.2.840.10008.9.19

>

entry

0..1

COND

>>

procedure

1..1

SHALL

>>@

@classCode

1..1

SHALL

CS

SHALL

PROC

>>@

@moodCode

1..1

SHALL

CS

SHALL

EVN

>>>

code

1..1

SHALL

CD

SHALL

(121290, DCM, "Patient exposure to ionizing radiation")

>>>

participant

1..1

SHALL

>>@

@typeCode

1..1

SHALL

CS

SHALL

RESP

>>>

participant​Role

1..1

SHALL

Irradiation​Authorizing​ID

>>>>

id

1..1

SHALL

II

>>>>

function​Code

1..1

SHALL

CE

SHALL

(113850, DCM, "Irradiation Authorizing")

>>>>

playing​Entity

1..1

SHALL

Irradiation​Authorizing​Name

>>>>>

name

1..1

SHALL

PN

>

entry

0..*

MAY

SOPInstance[*]

>>

observation

1..1

SHALL

10.8 SOP Instance Observation 1.2.840.10008.9.18

>

entry

1..1

COND

Coded​Observation​[pregnancy]

>>

observation

1..1

SHALL

[See 9.8.5.4 entry/observation Pregnancy]

10.1 Coded Observation 2.16.840.1.113883.​10.20.6.2.13

>

entry

0..1

MAY

Coded​Observation​[indication]

>>

observation

1..1

SHALL

[See 9.8.5.5 entry/observation Indication]

10.1 Coded Observation 2.16.840.1.113883.​10.20.6.2.13

>

entry

0..*

MAY

Quantity​Measurement[*]

>>

observation

1..1

[See 9.8.5.6 entry/observation Dose Measurements]

10.5 Quantity Measurement 2.16.840.1.113883.​10.20.6.2.14

>

entry

0..1

MAY

>>

substance​Administration

>>@

@classCode

1..1

SHALL

SHALL

SBADM

>>@

@moodCode

1..1

SHALL

SHALL

EVN

>>>

code

1..1

SHALL

(440252007, SNOMED, "Administration of radiopharmaceutical")

Radioactivity​Dose

>>>

dose​Quantity

0..1

SHOULD

PQ

>>>

consumable

1..1

SHALL

>>>>

manufactured​Product

1..1

SHALL

>>>>>

material

1..1

SHALL

Radio​pharmaceutical

>>>>>>

code

1..1

SHALL

CE

SHOULD

CWE

ValueSet CID 25 “Radiopharmaceuticals”, or CID 4021 “PET Radiopharmaceutical”

Free​Text​Radio​pharmaceutical

>>>>>>>

original Text

0..1

SHOULD

ED

9.8.5.1 text

The section text SHALL contain information related to the radiation exposure and protection of the patient, as is required by state/national legal requirements or standards, for example:

  • information on the indications for the procedure

  • the name of the "Irradiation Authorizing" person who is the clinician responsible for determining that the irradiating procedure was appropriate for the indications.

  • summary information on radiation exposure if ionizing is applied in the context of the current procedure (detailed specification of exposure is out of the scope of this textual summary).

  • information on the radioactive substance administered if radioactive substance is administered in the context of the current procedure.