DICOM PS3.20 2019b - Imaging Reports using HL7 Clinical Document Architecture

9.8.5.6 entry/observation Dose Measurements

The section may include multiple dose measurements. The binding to the Quantity Measurement concept domains is:

Concept Domain or Element

Value Conf

Value

Observation​Type

SHALL CWE

Value​Set CID 10050 “Summary Radiation Exposure Quantities”

Other concept domains

unspecified

Example 9.8.5.6-1. Radiation Exposure and Protection section example

<section classCode="DOCSECT" moodCode="EVN">
	<templateId root="1.2.840.10008.9.8" />
	<id root="1.2.840.10213.2.62.704478559484.11428372623"/>
	<code code="73569-6"
		codeSystem="2.16.840.1.113883.6.1"
		codeSystemName="LOINC"
		displayName="Radiation Exposure And Protection Information"/>
	<title> Radiation Exposure and Protection Information</title>
	<text>A dosage of... </text>
	<entry>
		<procedure classCode="PROC" moodCode="EVN">
			<code code="121290"
			    codeSystem="2.16.840.1.113883.6.1"
			    codeSystemName="DCM"
			    displayName="Patient exposure to ionizing radiation"/>
			<participant typeCode="RESP">
				<participantRole>
					<id root="2.16.840.1.113883.4.6" extension="980003719"/>
					<code code="113850"
					    codeSystem="2.16.840.1.113883.6.1"
					    codeSystemName="DCM"
					    displayName="Irradiation Authorizing"/>
					<playingEntity>
						<name>
							<given>Martha</given>
							<family>Radiologist</family>
						</name>
					</playingEntity>
				</participantRole>
			</participant>
		</procedure>
	</entry>
	<entry>
		<observation classCode="OBS" moodCode="EVN" ID="pregnancy">
			<templateId root="2.16.840.1.113883.10.20.6.2.13"/>
			<id root="1.2.840.10213.2.62.7044779.114265201"/>
			<code code="364320009"
			    codeSystem="2.16.840.1.113883.6.96"
			    codeSystemName="SNOMED CT"
			    displayName="Pregnancy observable"/>
			<statusCode code="completed"/>
			<value xsi:type="CD" code="60001007"
			    codeSystem="2.16.840.1.113883.6.96"
			    codeSystemName="SNOMED CT"
			    displayName="not pregnant"/>
			<effectiveTime value="20140914171504+0500"/>
		</observation>
	</entry>
</section>

DICOM PS3.20 2019b - Imaging Reports using HL7 Clinical Document Architecture