DICOM PS3.20 2020b - Imaging Reports using HL7 Clinical Document Architecture

10.9 Image Quality

Template ID

1.2.840.10008.9.15

Name

Image Quality

Effective Date

2015/03/24

Version Label

DICOM-20150324

Status

Active

Description

Provides a quality assessment for the image set identified by the invoking section. By default unless otherwise identified, applies to the image set interpreted by the document (typically a Study). If the quality rating applies to only a subset of the Study (e.g., a Series, or a specific Image), that subset shall be identified in the invoking section.

Classification

CDA Entry Level

Relationships

Included in 9.3 Imaging Procedure Description

Context

parent node

Open/Closed

open

Revision History

DICOM-20150324: Initial version Derived from Coded Observation

Name

Nest Level

Element/​Attribute

Card

Elem/Attr Conf

Data Type

Value Conf

Value

Subsidiary Template

Image​Quality

observation

1..1

SHALL

@

@classCode

1..1

SHALL

CS

SHALL

OBS

@

@moodCode

1..1

SHALL

CS

SHALL

EVN

>

template​Id

1..1

SHALL

II

>@

@root

1..1

SHALL

UID

SHALL

1.2.840.10008.9.15

>

id

1..1

SHALL

II

>

code

1..1

SHALL

CD

(111050, DCM, "Image Quality Assessment")

>

text

0..1

SHOULD

Ref

>>

reference

1..1

SHALL

URL (XML IDREF)

# content​Ref

>

status​Code

1..1

SHALL

CS

SHALL

COMPLETED

Rating

>

value

1..1

SHALL

CD

SHOULD CWE

ValueSet CID 7036 “Image Quality Assessment”

>@

@xsi:type

1..1

SHALL

ST

SHALL

CD

10.9.1 text/reference and Related Narrative Block Markup

The Observation entry SHOULD include a text/reference element, whose value attribute (not to be confused with the value element of the Observation class) SHALL begin with a '#' and SHALL point to its corresponding narrative in the parent section (using the approach defined in CDA Release 2, section 4.3.5.1). See Section 9.1.1.1.

Example 10.9-1. Image Quality example

<observation classCode="OBS" moodCode="EVN">
    <templateId root="1.2.840.10008.9.15"/>
    <id root="1.2.840.113619.2.62.994044785528.20060823.200608232232322.3"/>
    <code code="111050" codeSystem="1.2.840.10008.2.6.1"
        codeSystemName="DCM"
        displayName="Image Quality Assessment"/>
    <text>
        <reference value="#Q9"/>
    </text>
    <statusCode code="completed"/>
    <value xsi:type="CD" code="RID12"
        codeSystem="2.16.840.1.113883.6.256"
        codeSystemName="RADLEX"
        displayName="Diagnostic quality"/>
</observation>

DICOM PS3.20 2020b - Imaging Reports using HL7 Clinical Document Architecture