DICOM PS3.20 2019c - Imaging Reports using HL7 Clinical Document Architecture

10.4 Procedure Technique

Template ID

1.2.840.10008.9.14

Name

Procedure Technique

Effective Date

2015/03/24

Version Label

DICOM-20150324

Status

Active

Description

The Procedure Technique entry allows the encoding of various parameters of the image acquisition. Other details may be found in other entries (e.g., procedural medication).

Classification

CDA Entry Level

Relationships

Included in 9.3 Imaging Procedure Description and 9.4 Comparison Study

Context

parent node

Open/Closed

Open

Revision History

DICOM-20150324: Initial version

Business Name

Nest Level

Element/​Attribute

Card

Elem/Attr Conf

Data Type

Value Conf

Value

Subsidiary Template

Procedure​Technique

procedure

1..1

SHALL

@

@classCode

1..1

SHALL

CS

SHALL

PROC

@

@moodCode

1..1

SHALL

CS

SHALL

EVN

>

template​Id

1..1

SHALL

II

>@

@root

1..1

SHALL

UID

1.2.840.10008.9.14

>

id

1..1

SHALL

II

Procedure​Code

>

code

1..1

SHALL

CD

Concept​Domain ProcedureCode

>

text

0..1

SHOULD

ED

Ref

>>

reference

1..1

SHALL

URL (XML IDREF)

# content​Ref

Effective​Time

>

effective​Time

0..1

SHOULD

IVL <TS>

Modality

>

method​Code

1..*

SHALL

CD

SHALL CNE

ValueSet CID 29 “Acquisition Modality”

Method​Code

>

method​Code

0..*

MAY

CD

Concept​Domain ImagingTechnique

Target​Site

>

target​Site​Code

0..*

SHOULD

CD

Concept​Domain TargetSite

>>

qualifier

0..1

COND

>>>

name

1..1

SHALL

CD

SHALL

(272741003, SNOMED CT, "laterality")

Laterality

>>>

value

1..1

SHALL

CD

SHALL CNE

ValueSet CID 244 “Laterality”

>

participation

0..1

COND

>@

@typecode

1..1

SHALL

CS

SHALL

LOC

>>

participant​Role

1..1

SHALL

>>@

class​Code

1..1

SHALL

CS

SHALL

SDLOC

>>>

scoping​Entity

1..1

SHALL

Provider​Organization

>>>>

desc

1..1

SHALL

ST

10.4.1 id

procedure/id does not correspond to any DICOM UID, but is an arbitrary identifier for this entry.

Example 10.4-1. Procedure Technique template example

<procedure moodCode="EVN" classCode="PROC">
    <templateId root="1.2.840.10008.9.14"/>
    <id root="1.2.840.6544.33.9100653988998717.997527582345600170"/>
    <code code="RPID465"
        displayName="MR NECK ANGIOGRAPHY"
        codeSystem="2.16.840.1.113883.6.256"
        codeSystemName="RadLex"/>
    <text><reference value="#proc"/></text>
    <effectiveTime value="20140913222400"/>
    <methodCode code="MR"
        displayName="Magnetic Resonance"
        codeSystem="1.2.840.10008.2.16.4" codeSystemName="DCM"/>
    <targetSiteCode code="45048000"
        codeSystem="2.16.840.1.113883.6.96" codeSystemName="SNOMED CT"
        displayName="Neck (structure)">
    </targetSiteCode>
</procedure>

DICOM PS3.20 2019c - Imaging Reports using HL7 Clinical Document Architecture