DICOM PS3.19 2019c - Application Hosting

B Interface Definitions

B.1 Application Interface - Version 20100825

B.1.1 WSDL Definition of the Interface

The following is the content of ApplicationService-20100825.wsdl:

<?xml version="1.0" encoding="utf-8"?>
<wsdl:definitions name="ApplicationService-20100825"
targetNamespace="http://dicom.nema.org/PS3.19/ApplicationService-20100825"
xmlns:tns="http://dicom.nema.org/PS3.19/ApplicationService-20100825"
xmlns:soap="http://schemas.xmlsoap.org/wsdl/soap/"
xmlns:wsu="http://docs.oasis-open.org/wss/2004/01/oasis-200401-wss-wssecurity-utility-1.0.xsd"
xmlns:soapenc="http://schemas.xmlsoap.org/soap/encoding/"
xmlns:wsam="http://www.w3.org/2007/05/addressing/metadata"
xmlns:wsa="http://schemas.xmlsoap.org/ws/2004/08/addressing"
xmlns:wsp="http://schemas.xmlsoap.org/ws/2004/09/policy"
xmlns:wsap="http://schemas.xmlsoap.org/ws/2004/08/addressing/policy"
xmlns:xsd="http://www.w3.org/2001/XMLSchema"
xmlns:msc="http://schemas.microsoft.com/ws/2005/12/wsdl/contract"
xmlns:wsaw="http://www.w3.org/2006/05/addressing/wsdl"
xmlns:soap12="http://schemas.xmlsoap.org/wsdl/soap12/"
xmlns:wsa10="http://www.w3.org/2005/08/addressing"
xmlns:wsx="http://schemas.xmlsoap.org/ws/2004/09/mex"
xmlns:wsdl="http://schemas.xmlsoap.org/wsdl/">
  <wsdl:types>
    <xsd:schema targetNamespace="http://dicom.nema.org/PS3.19/Imports/ApplicationService-20100825">

      <xsd:import namespace="http://dicom.nema.org/PS3.19/ApplicationService-20100825"
      schemaLocation="./ApplicationService-20100825.xsd" />
      <xsd:import namespace="http://schemas.microsoft.com/2003/10/Serialization/"
      schemaLocation="./Types.xsd" />
      <xsd:import namespace="http://schemas.microsoft.com/2003/10/Serialization/Arrays"
      schemaLocation="./ArrayOfString.xsd" />
      <xsd:import namespace="http://schemas.datacontract.org/2004/07/System.Xml.XPath"
      schemaLocation="./XPathNodeType.xsd" />
    </xsd:schema>
  </wsdl:types>
  <wsdl:message name="IApplicationService_GetState_InputMessage">
    <wsdl:part name="parameters" element="tns:GetState" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_GetState_OutputMessage">
    <wsdl:part name="parameters" element="tns:GetStateResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_SetState_InputMessage">
    <wsdl:part name="parameters" element="tns:SetState" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_SetState_OutputMessage">
    <wsdl:part name="parameters" element="tns:SetStateResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_BringToFront_InputMessage">
    <wsdl:part name="parameters" element="tns:BringToFront" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_BringToFront_OutputMessage">
    <wsdl:part name="parameters" element="tns:BringToFrontResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_NotifyDataAvailable_InputMessage">
    <wsdl:part name="parameters" element="tns:NotifyDataAvailable" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_NotifyDataAvailable_OutputMessage">
    <wsdl:part name="parameters" element="tns:NotifyDataAvailableResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_GetData_InputMessage">
    <wsdl:part name="parameters" element="tns:GetData" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_GetData_OutputMessage">
    <wsdl:part name="parameters" element="tns:GetDataResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_ReleaseData_InputMessage">
    <wsdl:part name="parameters" element="tns:ReleaseData" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_ReleaseData_OutputMessage">
    <wsdl:part name="parameters" element="tns:ReleaseDataResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_GetAsModels_InputMessage">
    <wsdl:part name="parameters" element="tns:GetAsModels" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_GetAsModels_OutputMessage">
    <wsdl:part name="parameters" element="tns:GetAsModelsResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_ReleaseModels_InputMessage">
    <wsdl:part name="parameters" element="tns:ReleaseModels" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_ReleaseModels_OutputMessage">
    <wsdl:part name="parameters" element="tns:ReleaseModelsResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_QueryModel_InputMessage">
    <wsdl:part name="parameters" element="tns:QueryModel" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_QueryModel_OutputMessage">
    <wsdl:part name="parameters" element="tns:QueryModelResponse" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_QueryInfoSet_InputMessage">
    <wsdl:part name="parameters" element="tns:QueryInfoSet" />
  </wsdl:message>
  <wsdl:message name="IApplicationService_QueryInfoSet_OutputMessage">
    <wsdl:part name="parameters" element="tns:QueryInfoSetResponse" />
  </wsdl:message>
  <wsdl:portType name="IApplicationService-20100825">
    <wsdl:operation name="GetState">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/GetState"
      message="tns:IApplicationService_GetState_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/GetStateResponse"
      message="tns:IApplicationService_GetState_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="SetState">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/SetState"
      message="tns:IApplicationService_SetState_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/SetStateResponse"
      message="tns:IApplicationService_SetState_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="BringToFront">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/BringToFront"
      message="tns:IApplicationService_BringToFront_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/BringToFrontResponse"
      message="tns:IApplicationService_BringToFront_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="NotifyDataAvailable">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/NotifyDataAvailable"
      message="tns:IApplicationService_NotifyDataAvailable_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/NotifyDataAvailableResponse"
      message="tns:IApplicationService_NotifyDataAvailable_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="GetData">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/GetData"
      message="tns:IApplicationService_GetData_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/GetDataResponse"
      message="tns:IApplicationService_GetData_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="ReleaseData">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/ReleaseData"
      message="tns:IApplicationService_ReleaseData_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/ReleaseDataResponse"
      message="tns:IApplicationService_ReleaseData_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="GetAsModels">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/GetAsModels"
      message="tns:IApplicationService_GetAsModels_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/GetAsModelsResponse"
      message="tns:IApplicationService_GetAsModels_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="ReleaseModels">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/ReleaseModels"
      message="tns:IApplicationService_ReleaseModels_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/ReleaseModelsResponse"
      message="tns:IApplicationService_ReleaseModels_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="QueryModel">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/QueryModel"
      message="tns:IApplicationService_QueryModel_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/QueryModelResponse"
      message="tns:IApplicationService_QueryModel_OutputMessage" />
    </wsdl:operation>
    <wsdl:operation name="QueryInfoSet">
      <wsdl:input wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/QueryInfoSet"
      message="tns:IApplicationService_QueryInfoSet_InputMessage" />
      <wsdl:output
        wsaw:Action="http://dicom.nema.org/PS3.19/IApplicationService/QueryInfoSetResponse"
      message="tns:IApplicationService_QueryInfoSet_OutputMessage" />
    </wsdl:operation>
  </wsdl:portType>
  <wsdl:binding name="ApplicationService-20100825Binding"
  type="tns:IApplicationService-20100825">
    <soap:binding transport="http://schemas.xmlsoap.org/soap/http" />
    <wsdl:operation name="GetState">
      <soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/GetState"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="SetState">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/SetState"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="BringToFront">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/BringToFront"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="NotifyDataAvailable">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/NotifyDataAvailable"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="GetData">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/GetData"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="ReleaseData">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/ReleaseData"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="GetAsModels">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/GetAsModels"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="ReleaseModels">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/ReleaseModels"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="QueryModel">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/QueryModel"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
    <wsdl:operation name="QueryInfoSet">
      <<soap:operation
         soapAction="http://dicom.nema.org/PS3.19/IApplicationService/QueryInfoSet"
      style="document" />
      <wsdl:input>
        <soap:body use="literal" />
      </wsdl:input>
      <wsdl:output>
        <soap:body use="literal" />
      </wsdl:output>
    </wsdl:operation>
  </wsdl:binding>
  <wsdl:service name="ApplicationService-20100825">
    <wsdl:port name="ApplicationServiceBinding"
    binding="tns:ApplicationService-20100825Binding">
      <soap:address location="http://localhost/Service" />
    </wsdl:port>
  </wsdl:service>
</wsdl:definitions>

B.1.2 Definition of Data Structures Used

B.1.2.1 Primary Definitions

The following is the content of ApplicationService-20100825.xsd

<?xml version="1.0" encoding="utf-8"?>
<xs:schema xmlns:tns="http://dicom.nema.org/PS3.19/ApplicationService-20100825"
elementFormDefault="qualified"
targetNamespace="http://dicom.nema.org/PS3.19/ApplicationService-20100825"
xmlns:xs="http://www.w3.org/2001/XMLSchema">
  <xs:import namespace="http://schemas.microsoft.com/2003/10/Serialization/Arrays" />
  <xs:import namespace="http://schemas.datacontract.org/2004/07/System.Xml.XPath" />
  <xs:element name="GetState">
    <xs:complexType>
      <xs:sequence />
    </xs:complexType>
  </xs:element>
  <xs:element name="GetStateResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="GetStateResult" type="tns:State" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:simpleType name="State">
    <xs:restriction base="xs:string">
      <xs:enumeration value="IDLE" />
      <xs:enumeration value="INPROGRESS" />
      <xs:enumeration value="SUSPENDED" />
      <xs:enumeration value="COMPLETED" />
      <xs:enumeration value="CANCELED" />
      <xs:enumeration value="EXIT" />
    </xs:restriction>
  </xs:simpleType>
  <xs:element name="State" nillable="true" type="tns:State" />
  <xs:element name="SetState">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="state" type="tns:State" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="SetStateResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="SetStateResult" type="xs:boolean" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="BringToFront">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="location" nillable="true"
        type="tns:Rectangle" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="Rectangle">
    <xs:sequence>
      <xs:element minOccurs="0" name="Height" type="xs:int" />
      <xs:element minOccurs="0" name="Width" type="xs:int" />
      <xs:element minOccurs="0" name="RefPointX" type="xs:int" />
      <xs:element minOccurs="0" name="RefPointY" type="xs:int" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="Rectangle" nillable="true" type="tns:Rectangle" />
  <xs:element name="BringToFrontResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="BringToFrontResult"
        type="xs:boolean" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="NotifyDataAvailable">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="data" nillable="true"
        type="tns:AvailableData" />
        <xs:element minOccurs="0" name="lastData" type="xs:boolean" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="AvailableData">
    <xs:sequence>
      <xs:element minOccurs="0" name="ObjectDescriptors" nillable="true"
      type="tns:ArrayOfObjectDescriptor" />
      <xs:element minOccurs="0" name="Patients" nillable="true"
      type="tns:ArrayOfPatient" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="AvailableData" nillable="true" type="tns:AvailableData" />
  <xs:complexType name="ArrayOfObjectDescriptor">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="ObjectDescriptor"
      nillable="true" type="tns:ObjectDescriptor" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfObjectDescriptor" nillable="true"
  type="tns:ArrayOfObjectDescriptor" />
  <xs:complexType name="ObjectDescriptor">
    <xs:sequence>
      <xs:element minOccurs="0" name="ClassUID" nillable="true"
      type="tns:UID" />
      <xs:element minOccurs="0" name="MimeType" nillable="true"
      type="tns:MimeType" />
      <xs:element minOccurs="0" name="Modality" nillable="true"
      type="tns:Modality" />
      <xs:element minOccurs="0" name="TransferSyntaxUID" nillable="true"
      type="tns:UID" />
      <xs:element minOccurs="0" name="DescriptorUuid" nillable="true"
      type="tns:UUID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ObjectDescriptor" nillable="true"
  type="tns:ObjectDescriptor" />
  <xs:complexType name="UID">
    <xs:sequence>
      <xs:element minOccurs="0" name="Uid" nillable="true" type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="UID" nillable="true" type="tns:UID" />
  <xs:complexType name="MimeType">
    <xs:sequence>
      <xs:element minOccurs="0" name="Type" nillable="true" type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="MimeType" nillable="true" type="tns:MimeType" />
  <xs:complexType name="Modality">
    <xs:sequence>
      <xs:element minOccurs="0" name="Modality" nillable="true"
      type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="Modality" nillable="true" type="tns:Modality" />
  <xs:complexType name="UUID">
    <xs:sequence>
      <xs:element minOccurs="0" name="Uuid" nillable="true" type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="UUID" nillable="true" type="tns:UUID" />
  <xs:complexType name="ArrayOfPatient">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="Patient"
      nillable="true" type="tns:Patient" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfPatient" nillable="true"
  type="tns:ArrayOfPatient" />
  <xs:complexType name="Patient">
    <xs:sequence>
      <xs:element minOccurs="0" name="AssigningAuthority" nillable="true"
      type="xs:string" />
      <xs:element minOccurs="0" name="DateOfBirth" type="xs:dateTime" />
      <xs:element minOccurs="0" name="ID" nillable="true" type="xs:string" />
      <xs:element minOccurs="0" name="Name" nillable="true" type="xs:string" />
      <xs:element minOccurs="0" name="ObjectDescriptors" nillable="true"
      type="tns:ArrayOfObjectDescriptor" />
      <xs:element minOccurs="0" name="Sex" nillable="true" type="xs:string" />
      <xs:element minOccurs="0" name="Studies" nillable="true"
      type="tns:ArrayOfStudy" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="Patient" nillable="true" type="tns:Patient" />
  <xs:complexType name="ArrayOfStudy">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="Study"
      nillable="true" type="tns:Study" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfStudy" nillable="true" type="tns:ArrayOfStudy" />
  <xs:complexType name="Study">
    <xs:sequence>
      <xs:element minOccurs="0" name="ObjectDescriptors" nillable="true"
      type="tns:ArrayOfObjectDescriptor" />
      <xs:element minOccurs="0" name="Series" nillable="true"
      type="tns:ArrayOfSeries" />
      <xs:element minOccurs="0" name="StudyUID" nillable="true"
      type="tns:UID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="Study" nillable="true" type="tns:Study" />
  <xs:complexType name="ArrayOfSeries">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="Series"
      nillable="true" type="tns:Series" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfSeries" nillable="true" type="tns:ArrayOfSeries" />
  <xs:complexType name="Series">
    <xs:sequence>
      <xs:element minOccurs="0" name="ObjectDescriptors" nillable="true"
      type="tns:ArrayOfObjectDescriptor" />
      <xs:element minOccurs="0" name="SeriesUID" nillable="true"
      type="tns:UID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="Series" nillable="true" type="tns:Series" />
  <xs:element name="NotifyDataAvailableResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="NotifyDataAvailableResult"
        type="xs:boolean" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="GetData">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="objects" nillable="true"
        type="tns:ArrayOfUUID" />
        <xs:element minOccurs="0" name="acceptableTransferSyntaxes"
        nillable="true" type="tns:ArrayOfUID" />
        <xs:element minOccurs="0" name="includeBulkData" type="xs:boolean" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="ArrayOfUUID">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="UUID"
      nillable="true" type="tns:UUID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfUUID" nillable="true" type="tns:ArrayOfUUID" />
  <xs:complexType name="ArrayOfUID">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="UID"
      nillable="true" type="tns:UID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfUID" nillable="true" type="tns:ArrayOfUID" />
  <xs:element name="GetDataResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="GetDataResult" nillable="true"
        type="tns:ArrayOfObjectLocator" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="ArrayOfObjectLocator">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="ObjectLocator"
      nillable="true" type="tns:ObjectLocator" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfObjectLocator" nillable="true"
  type="tns:ArrayOfObjectLocator" />
  <xs:complexType name="ObjectLocator">
    <xs:sequence>
      <xs:element minOccurs="0" name="Length" type="xs:long" />
      <xs:element minOccurs="0" name="Offset" type="xs:long" />
      <xs:element minOccurs="0" name="TransferSyntax" nillable="true"
      type="tns:UID" />
      <xs:element minOccurs="0" name="URI" nillable="true" type="xs:anyURI" />
      <xs:element minOccurs="0" name="Locator" nillable="true"
      type="tns:UUID" />
      <xs:element minOccurs="0" name="Source" nillable="true"
      type="tns:UUID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ObjectLocator" nillable="true" type="tns:ObjectLocator" />
  <xs:element name="ReleaseData">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="objects" nillable="true"
        type="tns:ArrayOfUUID" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="ReleaseDataResponse">
    <xs:complexType>
      <xs:sequence />
    </xs:complexType>
  </xs:element>
  <xs:element name="GetAsModels">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="objects" nillable="true"
        type="tns:ArrayOfUUID" />
        <xs:element minOccurs="0" name="classUID" nillable="true"
        type="tns:UID" />
        <xs:element minOccurs="0" name="supportedInfoSetTypes" nillable="true"
        type="tns:ArrayOfMimeType" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="ArrayOfMimeType">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="MimeType"
      nillable="true" type="tns:MimeType" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfMimeType" nillable="true"
  type="tns:ArrayOfMimeType" />
  <xs:element name="GetAsModelsResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="GetAsModelsResult" nillable="true"
        type="tns:ModelSetDescriptor" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="ModelSetDescriptor">
    <xs:sequence>
      <xs:element minOccurs="0" name="FailedSourceObjects" nillable="true"
      type="tns:ArrayOfUUID" />
      <xs:element minOccurs="0" name="InfosetType" nillable="true"
      type="tns:MimeType" />
      <xs:element minOccurs="0" name="Models" nillable="true"
      type="tns:ArrayOfUUID" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ModelSetDescriptor" nillable="true"
  type="tns:ModelSetDescriptor" />
  <xs:element name="ReleaseModels">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="models" nillable="true"
        type="tns:ArrayOfUUID" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="ReleaseModelsResponse">
    <xs:complexType>
      <xs:sequence />
    </xs:complexType>
  </xs:element>
  <xs:element name="QueryModel">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="models" nillable="true"
        type="tns:ArrayOfUUID" />
        <xs:element minOccurs="0" name="xPaths" nillable="true"
        xmlns:q1="http://schemas.microsoft.com/2003/10/Serialization/Arrays"
        type="q1:ArrayOfstring" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="QueryModelResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="QueryModelResult" nillable="true"
        type="tns:ArrayOfQueryResult" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="ArrayOfQueryResult">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="QueryResult"
      nillable="true" type="tns:QueryResult" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfQueryResult" nillable="true"
  type="tns:ArrayOfQueryResult" />
  <xs:complexType name="QueryResult">
    <xs:sequence>
      <xs:element minOccurs="0" name="Model" nillable="true" type="tns:UUID" />
      <xs:element minOccurs="0" name="Result" nillable="true"
      type="tns:ArrayOfXPathNode" />
      <xs:element minOccurs="0" name="XPath" nillable="true"
      type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="QueryResult" nillable="true" type="tns:QueryResult" />
  <xs:complexType name="ArrayOfXPathNode">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="XPathNode"
      nillable="true" type="tns:XPathNode" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfXPathNode" nillable="true"
  type="tns:ArrayOfXPathNode" />
  <xs:complexType name="XPathNode">
    <xs:sequence>
      <xs:element minOccurs="0" name="NodeType"
      xmlns:q2="http://schemas.datacontract.org/2004/07/System.Xml.XPath"
      type="q2:XPathNodeType" />
      <xs:element minOccurs="0" name="Value" nillable="true"
      type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="XPathNode" nillable="true" type="tns:XPathNode" />
  <xs:element name="QueryInfoSet">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="models" nillable="true"
        type="tns:ArrayOfUUID" />
        <xs:element minOccurs="0" name="xPaths" nillable="true"
        xmlns:q3="http://schemas.microsoft.com/2003/10/Serialization/Arrays"
        type="q3:ArrayOfstring" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:element name="QueryInfoSetResponse">
    <xs:complexType>
      <xs:sequence>
        <xs:element minOccurs="0" name="QueryInfoSetResult" nillable="true"
        type="tns:ArrayOfQueryResultInfoSet" />
      </xs:sequence>
    </xs:complexType>
  </xs:element>
  <xs:complexType name="ArrayOfQueryResultInfoSet">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="QueryResultInfoSet"
      nillable="true" type="tns:QueryResultInfoSet" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfQueryResultInfoSet" nillable="true"
  type="tns:ArrayOfQueryResultInfoSet" />
  <xs:complexType name="QueryResultInfoSet">
    <xs:sequence>
      <xs:element minOccurs="0" name="Model" nillable="true" type="tns:UUID" />
      <xs:element minOccurs="0" name="Result" nillable="true"
      type="tns:ArrayOfXPathNodeInfoSet" />
      <xs:element minOccurs="0" name="XPath" nillable="true"
      type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="QueryResultInfoSet" nillable="true"
  type="tns:QueryResultInfoSet" />
  <xs:complexType name="ArrayOfXPathNodeInfoSet">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="XPathNodeInfoSet"
      nillable="true" type="tns:XPathNodeInfoSet" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfXPathNodeInfoSet" nillable="true"
  type="tns:ArrayOfXPathNodeInfoSet" />
  <xs:complexType name="XPathNodeInfoSet">
    <xs:sequence>
      <xs:element minOccurs="0" name="InfoSetValue" nillable="true"
      type="xs:base64Binary" />
      <xs:element minOccurs="0" name="NodeType"
      xmlns:q4="http://schemas.datacontract.org/2004/07/System.Xml.XPath"
      type="q4:XPathNodeType" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="XPathNodeInfoSet" nillable="true"
  type="tns:XPathNodeInfoSet" />
</xs:schema>

B.1.2.2 Referenced Definitions

The following is the content of XPathNodeType.xsd:

<?xml version="1.0" encoding="utf-8"?>
<xs:schema xmlns:tns="http://schemas.datacontract.org/2004/07/System.Xml.XPath"
elementFormDefault="qualified"
targetNamespace="http://schemas.datacontract.org/2004/07/System.Xml.XPath"
xmlns:xs="http://www.w3.org/2001/XMLSchema">
  <xs:simpleType name="XPathNodeType">
    <xs:restriction base="xs:string">
      <xs:enumeration value="Root" />
      <xs:enumeration value="Element" />
      <xs:enumeration value="Attribute" />
      <xs:enumeration value="Namespace" />
      <xs:enumeration value="Text" />
      <xs:enumeration value="SignificantWhitespace" />
      <xs:enumeration value="Whitespace" />
      <xs:enumeration value="ProcessingInstruction" />
      <xs:enumeration value="Comment" />
      <xs:enumeration value="All" />
    </xs:restriction>
  </xs:simpleType>
  <xs:element name="XPathNodeType" nillable="true" type="tns:XPathNodeType" />
</xs:schema>

The following is the content of Types.xsd:

<?xml version="1.0" encoding="utf-8"?>
<xs:schema xmlns:tns="http://schemas.microsoft.com/2003/10/Serialization/"
attributeFormDefault="qualified" elementFormDefault="qualified"
targetNamespace="http://schemas.microsoft.com/2003/10/Serialization/"
xmlns:xs="http://www.w3.org/2001/XMLSchema">
  <xs:element name="anyType" nillable="true" type="xs:anyType" />
  <xs:element name="anyURI" nillable="true" type="xs:anyURI" />
  <xs:element name="base64Binary" nillable="true" type="xs:base64Binary" />
  <xs:element name="boolean" nillable="true" type="xs:boolean" />
  <xs:element name="byte" nillable="true" type="xs:byte" />
  <xs:element name="dateTime" nillable="true" type="xs:dateTime" />
  <xs:element name="decimal" nillable="true" type="xs:decimal" />
  <xs:element name="double" nillable="true" type="xs:double" />
  <xs:element name="float" nillable="true" type="xs:float" />
  <xs:element name="int" nillable="true" type="xs:int" />
  <xs:element name="long" nillable="true" type="xs:long" />
  <xs:element name="QName" nillable="true" type="xs:QName" />
  <xs:element name="short" nillable="true" type="xs:short" />
  <xs:element name="string" nillable="true" type="xs:string" />
  <xs:element name="unsignedByte" nillable="true" type="xs:unsignedByte" />
  <xs:element name="unsignedInt" nillable="true" type="xs:unsignedInt" />
  <xs:element name="unsignedLong" nillable="true" type="xs:unsignedLong" />
  <xs:element name="unsignedShort" nillable="true" type="xs:unsignedShort" />
  <xs:element name="char" nillable="true" type="tns:char" />
  <xs:simpleType name="char">
    <xs:restriction base="xs:int" />
  </xs:simpleType>
  <xs:element name="duration" nillable="true" type="tns:duration" />
  <xs:simpleType name="duration">
    <xs:restriction base="xs:duration">
      <xs:pattern value="\-?P(\d*D)?(T(\d*H)?(\d*M)?(\d*(\.\d*)?S)?)?" />
      <xs:minInclusive value="-P10675199DT2H48M5.4775808S" />
      <xs:maxInclusive value="P10675199DT2H48M5.4775807S" />
    </xs:restriction>
  </xs:simpleType>
  <xs:element name="guid" nillable="true" type="tns:guid" />
  <xs:simpleType name="guid">
    <xs:restriction base="xs:string">
      <xs:pattern value="[\da-fA-F]{8}-[\da-fA-F]{4}-[\da-fA-F]{4}-[\da-fA-F]{4}-[\da-fA-F]{12}" />
    </xs:restriction>
  </xs:simpleType>
  <xs:attribute name="FactoryType" type="xs:QName" />
  <xs:attribute name="Id" type="xs:ID" />
  <xs:attribute name="Ref" type="xs:IDREF" />
</xs:schema>

The following is the content of ArrayOfString.xsd:

<?xml version="1.0" encoding="utf-8"?>
<xs:schema xmlns:tns="http://schemas.microsoft.com/2003/10/Serialization/Arrays"
elementFormDefault="qualified"
targetNamespace="http://schemas.microsoft.com/2003/10/Serialization/Arrays"
xmlns:xs="http://www.w3.org/2001/XMLSchema">
  <xs:complexType name="ArrayOfstring">
    <xs:sequence>
      <xs:element minOccurs="0" maxOccurs="unbounded" name="string"
      nillable="true" type="xs:string" />
    </xs:sequence>
  </xs:complexType>
  <xs:element name="ArrayOfstring" nillable="true" type="tns:ArrayOfstring" />
</xs:schema>
DICOM PS3.19 2019c - Application Hosting