F.4 DICOM JSON Model Example
// The following example is a QIDO-RS SearchForStudies response consisting
// of two matching studies, corresponding to the example QIDO-RS request:
// GET http://qido.nema.org/studies?PatientID=12345&includefield=all&limit=2
[
{ // Result 1
"00080005": {
"vr": "CS",
"Value": [ "ISO_IR 192" ]
},
"00080020": {
"vr": "DT",
"Value": [ "20130409" ]
},
"00080030": {
"vr": "TM",
"Value": [ "131600.0000" ]
},
"00080050": {
"vr": "SH",
"Value": [ "11235813" ]
},
"00080056": {
"vr": "CS",
"Value": [ "ONLINE" ]
},
"00080061": {
"vr": "CS",
"Value": [
"CT",
"PET"
]
},
"00080090": {
"vr": "PN",
"Value": [
{
"Alphabetic": "^Bob^^Dr."
}
]
},
"00081190": {
"vr": "UR",
"Value": [ "http://wado.nema.org/studies/
1.2.392.200036.9116.2.2.2.1762893313.1029997326.945873" ]
},
"00090010": {
"vr": "LO",
"Value": [ "Vendor A" ]
},
"00091002": {
"vr": "UN",
"InlineBinary": "z0x9c8v7"
},
"00100010": {
"vr": "PN",
"Value": [
{
"Alphabetic": "Wang^XiaoDong",
"Ideographic": "王^小東"
}
]
},
"00100020": {
"vr": "LO",
"Value": [ "12345" ]
},
"00100021": {
"vr": "LO",
"Value": [ "Hospital A" ]
},
"00100030": {
"vr": "DT",
"Value": [ "19670701" ]
},
"00100040": {
"vr": "CS",
"Value": [ "M" ]
},
"00101002": {
"vr": "SQ",
"Value": [
{
"00100020": {
"vr": "LO",
"Value": [ "54321" ]
},
"00100021": {
"vr": "LO",
"Value": [ "Hospital B" ]
}
},
{
"00100020": {
"vr": "LO",
"Value": [ "24680" ]
},
"00100021": {
"vr": "LO",
"Value": [ "Hospital C" ]
}
}
]
},
"0020000D": {
"vr": "UI",
"Value": [ "1.2.392.200036.9116.2.2.2.1762893313.1029997326.945873" ]
},
"00200010": {
"vr": "SH",
"Value": [ "11235813" ]
},
"00201206": {
"vr": "IS",
"Value": [ 4 ]
},
"00201208": {
"vr": "IS",
"Value": [ 942 ]
}
},
{ // Result 2
"00080005": {
"vr": "CS",
"Value": [ "ISO_IR 192" ]
},
"00080020": {
"vr": "DT",
"Value": [ "20130309" ]
},
"00080030": {
"vr": "TM",
"Value": [ "111900.0000" ]
},
"00080050": {
"vr": "SH",
"Value": [ "11235821" ]
},
"00080056": {
"vr": "CS",
"Value": [ "ONLINE" ]
},
"00080061": {
"vr": "CS",
"Value": [
"CT",
"PET"
]
},
"00080090": {
"vr": "PN",
"Value": [
{
"Alphabetic": "^Bob^^Dr."
}
]
},
"00081190": {
"vr": "UR",
"Value": [ "http://wado.nema.org/studies/
1.2.392.200036.9116.2.2.2.2162893313.1029997326.945876" ]
},
"00090010": {
"vr": "LO",
"Value": [ "Vendor A" ]
},
"00091002": {
"vr": "UN",
"InlineBinary": [ "z0x9c8v7" ]
},
"00100010": {
"vr": "PN",
"Value": [
{
"Alphabetic": "Wang^XiaoDong",
"Ideographic": "王^小東"
}
]
},
"00100020": {
"vr": "LO",
"Value": [ "12345" ]
},
"00100021": {
"vr": "LO",
"Value": [ "Hospital A" ]
},
"00100030": {
"vr": "DT",
"Value": [ "19670701" ]
},
"00100040": {
"vr": "CS",
"Value": [ "M" ]
},
"00101002": {
"vr": "SQ",
"Value": [
{
"00100020": {
"vr": "LO",
"Value": [ "54321" ]
},
"00100021": {
"vr": "LO",
"Value": [ "Hospital B" ]
}
},
{
"00100020": {
"vr": "LO",
"Value": [ "24680" ]
},
"00100021": {
"vr": "LO",
"Value": [ "Hospital C" ]
}
}
]
},
"0020000D": {
"vr": "UI",
"Value": [ "1.2.392.200036.9116.2.2.2.2162893313.1029997326.945876" ]
},
"00200010": {
"vr": "SH",
"Value": [ "11235821" ]
},
"00201206": {
"vr": "IS",
"Value": [ 5 ]
},
"00201208": {
"vr": "IS",
"Value": [ 1123 ]
}
}
]