6.5.8.3 Response

The Retrieve Rendered service has the following response message syntax:

    version SP status-code SP reason-phrase CRLF
    Content-Type: rendered-media-type CRLF
    *(header-field CRLF)
    CRLF
    payload

Where

version

is the HTTP version, for example "HTTP/1.1"

rendered-media-type

is a Rendered Media Type; see Section 6.1.1.3.

payload

is one or more representations in a Rendered Media Type.

6.5.8.3.1 Status Codes

The response shall include a status code from Table 6.5.8-3, if applicable; otherwise, an appropriate status code shall be used.

Table 6.5.8-3. Common Status Codes

Status Code

Meaning

200 Success

The origin server successfully rendered and is returning representations for the resource.

206 Partial Content

The origin server successfully rendered and is returning representations for part, but not all, of the resource.

400 Bad Request

The origin cannot process the request because of errors in the request headers or parameters.

406 Not Acceptable

The origin server does not support any of the Acceptable Media Types.

413 Payload Too Large

The target resource is too large to be rendered by the origin server.