DICOM PS3.18 2020e - Web Services

11.8.3.2 Response Header Fields

The origin server shall support header fields as required in Table 11.8.3-2.

Table 11.8.3-2. Response Header Fields

Name

center

Origin Server Usage

Description

Content-Type

media-type

C

The media type of the Status Report document.

Shall be present if the response contains a payload.

Content-Length

uint

C

Shall be present if a content encoding has not been applied to the payload.

Content-Encoding

encoding

C

Shall be present if a content encoding has been applied to the payload.


If the Workitem Instance is already in a canceled state, the response message shall include the following HTTP Warning header field:

Warning: 299 <service>: The UPS is already in the requested state of CANCELED.

See also Section 8.4.

DICOM PS3.18 2020e - Web Services