10.6.3.3.2 Series Resources

For each matching Series, the origin server shall return all Attributes listed in Table 10.6.3-4. The "Type" column in the table below refers to the Query/Retrieve Attribute Types defined in Section C.2.2.1 “Attribute Types” in PS3.4. The unique key for a Series resource Search response is the Series Instance UID (0020,000E).

Table 10.6.3-4. Series Resources Search Response Payload

Attribute Name

Tag

Type

Condition

Modality

(0008,0060)

R

Timezone Offset From UTC

(0008,0201)

C

Shall be present if known

Series Description

(0008,103E)

C

Shall be present if known

Retrieve URL

(0008,1190)

R

Shall be present if the Instance is retrievable by the Retrieve transaction

Series Instance UID

(0020,000E)

U

Series Number

(0020,0011)

R

Number of Series Related Instances

(0020,1209)

R

Performed Procedure Step Start Date

(0040,0244)

C

Shall be present if known

Performed Procedure Step Start Time

(0040,0245)

C

Shall be present if known

Request Attributes Sequence

(0040,0275)

C

Shall be present if known

>Scheduled Procedure Step ID

(0040,0009)

R

>Requested Procedure ID

(0040,1001)

R


Note

While some of the above Attributes in are optional in Table C.6-1 “Patient Level Attributes for the Patient Root Query/Retrieve Information Model” in PS3.4, they are consistent with the those required in [IHE RAD TF Vol2] Table 4.14-1.

In addition, the response shall contain:

Instance Level Attributes contained in includefield parameters shall not be returned.