DICOM PS3.18 2020e - Web Services |
---|
An origin server claiming conformance to the Retrieve Transaction of the Studies Service:
shall support the Retrieve Capabilities Transaction (see Section 8.9.1);
shall support the Retrieve Transaction for all mandatory resources in Table 10.3-2.
An origin server claiming conformance to the Store Transaction of the Studies Service:
shall support the Retrieve Capabilities Transaction (see Section 8.9.1);
shall support the Store Transaction for all mandatory resources in Table 10.3-2.
An origin server claiming conformance to the Search Transaction of the Studies Service:
shall support the Retrieve Capabilities Transaction (see Section 8.9.1);
shall support the Search Transaction for all mandatory resources in Table 10.3-2.
The user agent may support any of the transactions for any of the corresponding resources in Table 10.3-2.
DICOM PS3.18 2020e - Web Services |
---|