DICOM PS3.17 2020b - Explanatory Information

N.3.15 Right Atrium / Inferior Vena Cava

Name of ASE Concept

Base Measurement Concept Name

Concept or Acquisition Context Modifiers

Right Atrium Systolic Pressure

(18070-3, LN, "Right Atrium Systolic Pressure")

Right Atrium Systolic Area

(17988-7, LN, "Right Atrium Area A4C view")

(272518008, SCT, "Cardiac Cycle Point") = (111973004, SCT, "Systole")

Inferior Vena Cava Diameter

(18006-7, LN, "Inferior Vena Cava Diameter")

Inferior Vena Cava Diameter at Inspiration

(18006-7, LN, "Inferior Vena Cava Diameter")

(272517003, SCT, "Respiratory Cycle Point") = (14910006, SCT, "During Inspiration")

Inferior Vena Cava Diameter at Expiration

(18006-7, LN, "Inferior Vena Cava Diameter")

(272517003, SCT, "Respiratory Cycle Point") = (58322009, SCT, "During Expiration")

Inferior Vena Cava % Collapse

(18050-5, LN, "Inferior Vena Cava % Collapse")

Hepatic Vein Systolic Peak Velocity

(29471-0, LN, "Hepatic Vein Systolic Peak Velocity")

Hepatic Vein Diastolic Peak Velocity

(29472-8, LN, "Hepatic Vein Diastolic Peak Velocity")

Hepatic Vein Systolic to Diastolic Ratio

(29473-6, LN, "Hepatic Vein Systolic to Diastolic Ratio")

Hepatic Vein Atrial Contraction Reversal Peak Velocity

(29474-4, LN, "Hepatic Vein Atrial Contraction Reversal Peak Velocity")

Hepatic Vein Peak Systolic Velocity at Inspiration

(29471-0, LN, "Hepatic Vein Systolic Peak Velocity")

(272517003, SCT, "Respiratory Cycle Point") = (14910006, SCT, "During Inspiration")

Hepatic Vein Peak Diastolic Velocity at Inspiration

(29472-8, LN, "Hepatic Vein Diastolic Peak Velocity")

(272517003, SCT, "Respiratory Cycle Point") = (14910006, SCT, "During Inspiration")

Hepatic Vein Systolic to Diastolic Ratio at Inspiration

(29473-6, LN, "Hepatic Vein Systolic to Diastolic Ratio")

(272517003, SCT, "Respiratory Cycle Point") = (14910006, SCT, "During Inspiration")

Hepatic Vein Peak Atrial Contraction Reversal Velocity at Inspiration

(29474-4, LN, "Hepatic Vein Atrial Contraction Reversal Peak Velocity")

(272517003, SCT, "Respiratory Cycle Point") = (14910006, SCT, "During Inspiration")

Hepatic Vein Peak Systolic Velocity at Expiration

(29471-0, LN, "Hepatic Vein Systolic Peak Velocity")

(272517003, SCT, "Respiratory Cycle Point") = (58322009, SCT, "During Expiration")

Hepatic Vein Peak Diastolic Velocity at Expiration

(29472-8, LN, "Hepatic Vein Diastolic Peak Velocity")

(272517003, SCT, "Respiratory Cycle Point") = (58322009, SCT, "During Expiration")

Hepatic Vein Systolic to Diastolic Ratio at Expiration

(29473-6, LN, "Hepatic Vein Systolic to Diastolic Ratio")

(272517003, SCT, "Respiratory Cycle Point") = (58322009, SCT, "During Expiration")

Hepatic Vein Peak Atrial Contraction Reversal Velocity at Expiration

(29474-4, LN, "Hepatic Vein Atrial Contraction Reversal Peak Velocity")

(272517003, SCT, "Respiratory Cycle Point") = (58322009, SCT, "During Expiration")

DICOM PS3.17 2020b - Explanatory Information