DICOM PS3.17 2019b - Explanatory Information

MMM.2 CT Example with Images and Presentation States

This example presumes that the Q/R SCP contains the same images and presentation states described in Annex LLL.

MMM.2.1 C-FIND and C-MOVE At Study Level With Classic View

Study Root Study Level C-FIND Request with Patient ID and Accession Number as keys:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Study Date

(0008,0020)

DA

0

Study Time

(0008,0030)

TM

0

Accession Number

(0008,0050)

SH

10

2263295914110886

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

8

CLASSIC

Modalities in Study

(0008,0061)

CS

0

SOP Classes in Study

(0008,0062)

UI

0

Referring Physician's Name

(0008,0090)

PN

0

Study Description

(0008,1030)

LO

0

Physicians of Record

(0008,1048)

PN

0

Name of Physicians Reading Study

(0008,1060)

PN

0

Admitting Diagnoses Description

(0008,1080)

LO

0

Patient's Name

(0010,0010)

PN

0

Patient's ID

(0010,0020)

LO

10

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

0

Patient's Birth Time

(0010,0032)

TM

0

Patient's Sex

(0010,0040)

CS

0

Patient's Age

(0010,1010)

AS

0

Patient's Size

(0010,1020)

DS

0

Patient's Weight

(0010,1030)

DS

0

Occupation

(0010,2180)

SH

0

Additional Patient History

(0010,21b0)

LT

0

Patient Comments

(0010,4000)

LT

0

Study Instance UID

(0020,000d)

UI

0

Study ID

(0020,0010)

SH

0

Other Study Numbers

(0020,1070)

IS

0

Number of Study Related Series

(0020,1206)

IS

0

Number of Study Related Instances

(0020,1208)

IS

0

Study Root Study Level C-FIND Response:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Study Date

(0008,0020)

DA

8

20061230

Study Time

(0008,0030)

TM

6

100000

Accession Number

(0008,0050)

SH

10

2263295914110886

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

8

CLASSIC

Modalities in Study

(0008,0061)

CS

6

CT\PR

SOP Classes in Study

(0008,0062)

UI

36

1.2.840.10008.5.1.4.1.1.11.1​\1.2.840.10008.5.1.4.1.1.2

Referring Physician's Name

(0008,0090)

PN

0

Study Description

(0008,1030)

LO

0

Physicians of Record

(0008,1048)

PN

0

Name of Physicians Reading Study

(0008,1060)

PN

0

Admitting Diagnoses Description

(0008,1080)

LO

0

Patient's Name

(0010,0010)

PN

6

277654

Patient's ID

(0010,0020)

LO

10

RIDER-2357766186

Patient's Birth Date

(0010,0030)

DA

8

19301018

Patient's Birth Time

(0010,0032)

TM

0

Patient's Sex

(0010,0040)

CS

0

Patient's Age

(0010,1010)

AS

0

Patient's Size

(0010,1020)

DS

0

Patient's Weight

(0010,1030)

DS

0

Occupation

(0010,2180)

SH

0

Additional Patient History

(0010,21b0)

LT

0

Patient Comments

(0010,4000)

LT

0

Study Instance UID

(0020,000d)

UI

3e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Study ID

(0020,0010)

SH

4

1234

Other Study Numbers

(0020,1070)

IS

0

Number of Study Related Series

(0020,1206)

IS

2

2

Number of Study Related Instances

(0020,1208)

IS

2

3

Study Root Study Level C-MOVE Request with Study Instance UID as unique key:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Query/Retrieve Level

(0008,0052)

CS

6

STUDY

Query/Retrieve View

(0008,0053)

CS

8

CLASSIC

Study Instance UID

(0020,000d)

UI

3e

1.3.6.1.4.1.9328.50.1.​331429121990566779475389049484716775937

Study Root Study Level C-MOVE Pending Responses illustrating SOP Instances retrieved:

Nesting

Attribute

Tag

VR

VL (hex)

Value

Affected SOP Class UID

(0000,0002)

UI

1c

1.2.840.10008.5.1.4.1.1.11.1

Affected SOP Instance UID

(0000,1000)

UI

38

1.2.276.0.7230010.3.1.4.2989371993.3196.1272478982.1246

Affected SOP Class UID

(0000,0002)

UI

1a

1.2.840.10008.5.1.4.1.1.2

Affected SOP Instance UID

(0000,1000)

UI

3e

1.3.6.1.4.1.9328.50.1.​118458571690318148036673922876743615666

Affected SOP Class UID

(0000,0002)

UI

1a

1.2.840.10008.5.1.4.1.1.2

Affected SOP Instance UID

(0000,1000)

UI

3c

1.3.6.1.4.1.9328.50.1.​21169049221871725649891126757390969029

Note

Only the Classic image instances and the original Presentation State that refers to it are transferred with this STUDY level request.

DICOM PS3.17 2019b - Explanatory Information