DICOM PS3.17 2019c - Explanatory Information

FF.3 Report Example

The following is a simple, non-comprehensive illustration of a report for a morphological examination with stenosis findings.

Example FF.3-1. Presentation of Report Example #1

Cardiovascular Analysis Report - Vascular MRI

  • Observer: John Doe

  • Procedure Description

    • Abdominal aorta-iliac angiography procedure

  • Vascular Morphological Analysis

    Anatomic Region = Abdominal Artery, Left

    • Left Gastric Artery

      • Findings:

        • Vessel Lumen Diameter: 2 mm

        • Vessel Lumen Cross Sectional Area: 3.4 mm2

        • Lesion Finding #1

          • Best illustration of finding <hyperlink to Image with ROI highlighted>

          • Associated Morphology: Stenosis

          • Stenosis type: Vasculitis

          • Shape: Eccentric

          • Minimum Vessel Lumen Diameter: 1 mm

          • Maximum Vessel Lumen Diameter: 1.5 mm

          • Mean Vessel Lumen Diameter: 1.2 mm

          • Minimum Vessel Lumen Cross-sectional Area: 1 mm2

          • Maximum Vessel Lumen Cross-sectional Area: 3 mm2

          • Stenotic Lesion Length: 5 mm

          • Minimum Lumen Area Stenosis: 45 %

          • Maximum Lumen Area Stenosis: 75 %

          • Mean Lumen Area Stenosis: 60%


Table FF.3-1. Example #1 Report Encoding

Nest

Code Meaning of Concept Name

Code Meaning or Example Value

TID

1

CT/MR Cardiovascular Analysis Report

TID 3900

1.1

Procedure Reported

Vascular MRI

TID 3900

1.2

Observer Name

John Doe

TID 1001

1.3

Language of Content Items and Descendents

English

TID 1204

1.4

Procedure Summary

TID 3901

1.4.1

Current Procedure Description

Abdominal aorta-iliac angiography procedure

TID 3901

1.5

Findings

TID 3902

1.5.1

Analysis Performed

Vascular Morphological Analysis

TID 3902

1.5.2

Artery of Abdomen

TID 3906

1.5.2.1

Laterality

Left

TID 3906

1.5.2.2

Findings

TID 3906

1.5.2.3.1

Finding Site

Gastric Artery

TID 3906

1.5.2.3.2

Vessel Lumen Diameter

2 mm

TID 3907

1.5.2.3.3

Vessel Lumen Cross Sectional Area

3.4 mm2

TID 3907

1.5.2.3.4

Lesion Finding

TID 3908

1.5.2.3.4.1

Identifier

1

TID 3908

1.5.2.3.4.2

Best Illustration of Findings (SCOORD)

<ROI specification>

TID 3909

1.5.2.3.4.2.1

<Image reference>

TID 3909

1.5.2.3.4.3

Associated Morphology

Stenosis

TID 3908

1.5.2.3.4.4

Type

Vasculitis

TID 3912

1.5.2.3.4.5

Shape

Eccentric

TID 3912

1.5.2.3.4.6

Vessel Lumen Diameter

1 mm

TID 3912

1.5.2.3.4.6.1

Qualifier Value

Minimum

TID 3912

1.5.2.3.4.7

Vessel Lumen Diameter

1.5 mm

TID 3912

1.5.2.3.4.7.1

Qualifier Value

Maximum

TID 3912

1.5.2.3.4.8

Vessel Lumen Diameter

1.2 mm

TID 3912

1.5.2.3.4.8.1

Qualifier Value

Mean

TID 3912

1.5.2.3.4.9

Vessel Lumen Cross-sectional Area

1 mm2

TID 3912

1.5.2.3.4.9.1

Qualifier Value

Minimum

TID 3912

1.5.2.3.4.10

Vessel Lumen Cross-sectional Area

3 mm2

TID 3912

1.5.2.3.4.10.1

Qualifier Value

Maximum

TID 3912

1.5.2.3.3.11

Stenotic Lesion Length

5 mm

TID 3912

1.5.2.3.4.12

Lumen Area Stenosis

45 %

TID 3912

1.5.2.3.4.12.1

Qualifier Value

Minimum

TID 3912

1.5.2.3.4.13

Lumen Area Stenosis

75 %

TID 3912

1.5.2.3.4.13.1

Qualifier Value

Maximum

TID 3912

1.5.2.3.4.14

Lumen Area Stenosis

60 %

TID 3912

1.5.2.3.4.14.1

Qualifier

Mean

TID 3912


DICOM PS3.17 2019c - Explanatory Information