DICOM PS3.16 2020b - Content Mapping Resource

TID 9007 General Relevant Patient Information

This Template collects a patient's relevant information for general purpose use. This Template, together with its subordinate Templates, describes the history of a patient's reproductive system, medications, substance use, environmental exposure, past procedures, risk factors, and indicated problems.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 9007. General Relevant Patient Information

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111517, DCM, "Relevant Patient Information")

1

M

2

>

HAS CONCEPT MOD

INCLUDE

DTID 1204 “Language of Content Item and Descendants”

1

M

3

>

CONTAINS

INCLUDE

DTID 3114 “Patient Assessment”

1

U

4

>

CONTAINS

INCLUDE

DTID 9002 “Medication, Substance, Environmental Exposure”

1

U

$ContainerConcept = EV (10160-0, LN, "History Of Medication Use")

$CodeConcept = EV (111516, DCM, "Medication Type")

5

>

CONTAINS

INCLUDE

DTID 9002 “Medication, Substance, Environmental Exposure”

1

U

$ContainerConcept = EV (111545, DCM, "Substance Use History")

$CodeConcept = EV (111546, DCM, "Used Substance Type")

$CodeValue = BCID 6089 “Substances”

6

>

CONTAINS

INCLUDE

DTID 9002 “Medication, Substance, Environmental Exposure”

1

U

$ContainerConcept = EV (111547, DCM, "Environmental Exposure History")

$CodeConcept = EV (111548, DCM, "Environmental Factor")

7

>

CONTAINS

INCLUDE

DTID 9003 “Previous Procedure”

1

U

$LateralityValue = BCID 244 “Laterality”

8

>

CONTAINS

INCLUDE

DTID 9004 “Indicated Problem”

1

U

$LateralityValue = BCID 244 “Laterality”

9

>

CONTAINS

INCLUDE

DTID 9005 “Risk Factor”

1

U

$RiskList = BCID 6087 “General Risk Factors”

$FamilyList = DCID 7451 “Family Member”

10

>

CONTAINS

INCLUDE

DTID 9001 “Gynecological History”

1

U

11

>

CONTAINS

INCLUDE

DTID 9006 “Obstetric History”

1

U

12

>

CONTAINS

INCLUDE

DTID 3802 “Cardiovascular Patient History”

1

U

13

>

CONTAINS

INCLUDE

DTID 351 “Previous Reports”

1

U


DICOM PS3.16 2020b - Content Mapping Resource