DICOM PS3.16 2019c - Content Mapping Resource

TID 5012 Ovaries Section

This Template contains metrics of ovary size.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 5012. Ovaries Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

DT (121070, DCM, "Findings")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (363698007, SCT, "Finding Site")

1

M

DT (15497006, SCT, "Ovary")

3

>

CONTAINS

INCLUDE

DTID 5016 “LWH Volume Group”

1

U

$GroupName = EV (15497006, SCT, "Ovary")

$Width = EV (11829-9, LN, "Left Ovary Width")

$Length = EV (11840-6, LN, "Left Ovary Length")

$Height = EV (11857-0, LN, "Left Ovary Height")

$Volume = EV (12164-0, LN, "Left Ovary Volume")

4

>

CONTAINS

INCLUDE

DTID 5016 “LWH Volume Group”

1

U

$GroupName = EV (15497006, SCT, "Ovary")

$Width = EV (11830-7, LN, "Right Ovary Width")

$Length = EV (11841-4, LN, "Right Ovary Length")

$Height = EV (11858-8, LN, "Right Ovary Height")

$Volume = EV (12165-7, LN, "Right Ovary Volume")


DICOM PS3.16 2019c - Content Mapping Resource