DICOM PS3.16 2019c - Content Mapping Resource

TID 4208 Breast Imaging Report Supplementary Data

This Template forms a supplementary data sub-tree of the content tree of a Breast Imaging Report. Each subsection provides a specific type of supporting evidence to the narrative text sub-tree, for example, as coded and numeric data.

See Figure Q.1-4 “Breast Imaging Report Supplementary Data Content Tree” in PS3.17 .

Type:

Non-Extensible

Order:

Significant

Root:

No

Table TID 4208. Breast Imaging Report Supplementary Data

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (111414, DCM, "Supplementary Data")

1

M

2

>

CONTAINS

INCLUDE

DTID 4201 “Breast Imaging Procedure Reported”

1-n

M

3

>

CONTAINS

CODE

EV (111403, DCM, "Baseline screening mammogram")

1

U

DCID 230 “Yes-No”

4

>

CONTAINS

CODE

EV (111404, DCM, "First mammogram ever")

1

U

DCID 230 “Yes-No”

5

>

CONTAINS

INCLUDE

DTID 4205 “Breast Composition Section”

1

U

6

>

CONTAINS

INCLUDE

DTID 4206 “Breast Imaging Report Finding Section”

1-n

U

7

>

CONTAINS

INCLUDE

DTID 4204 “Breast Imaging Report Intervention Section”

1-n

U

8

>

CONTAINS

CONTAINER

EV (111413, DCM, "Overall Assessment")

1

U

9

>>

CONTAINS

INCLUDE

DTID 4203 “Breast Imaging Assessment”

1

M


DICOM PS3.16 2019c - Content Mapping Resource