DICOM PS3.16 2019a - Content Mapping Resource

TID 4205 Breast Composition Section

This Template defines a Breast Composition section for the supplementary data sub-tree of the Breast Imaging Report. It is included from TID 4208 “Breast Imaging Report Supplementary Data”.

Type:

Non-Extensible

Order:

Significant

Root:

No

Table TID 4205. Breast Composition Section

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (F-01710, SRT, "Breast composition")

1

M

2

>

CONTAINS

INCLUDE

DTID 4201 “Breast Imaging Procedure Reported”

1-n

U

3

>

CONTAINS

CODE

EV (F-01710, SRT, "Breast composition")

1-n

MC

At least one of row 3, 5 shall be present

DCID 6000 “Overall Breast Composition”

4

>>

HAS CONCEPT MOD

CODE

EV (G-C171, SRT, "Laterality")

1

M

DCID 6022 “Side”

5

>

CONTAINS

NUM

EV (111046, DCM, "Percent Fibroglandular Tissue")

1-n

MC

At least one of row 3, 5 shall be present

UNITS = EV (%, UCUM, "Percent")

6

>>

HAS CONCEPT MOD

CODE

EV (G-C171, SRT, "Laterality")

1

M

DCID 6022 “Side”

7

>

CONTAINS

CODE

EV (111350, DCM, "Breast background echo texture")

1-2

U

DCID 6151 “Background Echotexture”

8

>>

HAS CONCEPT MOD

CODE

EV (G-C171, SRT, "Laterality")

1

M

DCID 6022 “Side”


DICOM PS3.16 2019a - Content Mapping Resource