DICOM PS3.16 2020b - Content Mapping Resource

TID 3923 BSA-Normalized Ventricular Measurements

Ventricular measurement results normalized based on the Body Surface Area

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3923. BSA-Normalized Ventricular Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

EV (122609, DCM, "Normalized values of ventricular measurements")

1

M

2

>

HAS CONCEPT MOD

CODE

EV (121425, DCM, "Index")

1

M

DT (8277-6, LN, "Body Surface Area")

3

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (8277-6, LN, "Body Surface Area")

$Unit = DT (m2, UCUM, "m2")

4

>>

INFERRED FROM

CODE

EV (8278-4, LN, "Body Surface Area Formula")

1

U

BCID 3663 “Body Surface Area Equations”

5

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-n

U

$Measurement = DCID 3835 “Cardiac Volume Measurements”

$ModType = EV (121425, DCM, "Index")

$ModValue = DT (8277-6, LN, "Body Surface Area")

$Units = DT (ml/m2, UCUM, "ml/m2")

6

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (54993008, SCT, "Cardiac Index")

$Units = DT (ml/min/m2, UCUM, "(ml/min) /m2")

7

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1-2

U

$Measurement = EV (122447, DCM, "Wall Mass")

$ModType = EV (121425, DCM, "Index")

$ModValue = DT (8277-6, LN, "Body Surface Area")

$Units = DT (g/m2, UCUM, "g/m2")

8

>>

HAS CONCEPT MOD

CODE

DT (122670, DCM, "Papillary Muscle Included/Excluded")

1

U

DCID 3821 “Papillary Muscle Included/Excluded”

9

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (122618, DCM, "Peak Filling Rate")

$ModType = EV (121425, DCM, "Index")

$ModValue = DT (8277-6, LN, "Body Surface Area")

$Units = DT (ml/s/m2, UCUM, "(ml/s) /m2")

10

>

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (70822001, SCT, "Peak Cardiac Ejection Fraction")

$ModType = EV (121425, DCM, "Index")

$ModValue = DT (8277-6, LN, "Body Surface Area")

$Units = DT (%/m2, UCUM, "%/m2")


DICOM PS3.16 2020b - Content Mapping Resource