DICOM PS3.16 2019a - Content Mapping Resource

TID 3906 Vascular Section Measurements

Sections of vascular measurements are section containers of an anatomical region consisting of measurement group containers containing the measurements.

Table TID 3906. Parameters

Parameter Name

Parameter Usage

$VascularSection

The concept name of the region or structure of which the anatomy is part

$SectionLaterality

The laterality (if any) of the anatomy in this section heading

$Anatomy

The concept name of the vascular anatomy

$AnalysisPerformed

The context of the measurements performed during the analysis


Type:

Extensible

Order:

Significant

Root:

No

Table TID 3906. Vascular Section Measurements

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

CONTAINER

$VascularSection

1

M

2

>

HAS CONCEPT MOD

CODE

EV (G-C171, SRT, "Laterality")

1

MC

IFF $SectionLaterality has a value

$SectionLaterality

3

>

CONTAINS

CONTAINER

EV (121070, DCM, "Findings")

1-n

M

4

>>

HAS CONCEPT MOD

CODE

EV (G-C0E3, SRT, "Finding Site")

1

M

$Anatomy

5

>>

CONTAINS

CODE

EV (122686, DCM, "Parent Vessel Finding")

1-n

U

DCID 3810 “Vascular Morphology”

6

>>>

INCLUDE

DTID 1350 “Negation Modifier, Presence of Finding”

1

U

7

>>

CONTAINS

INCLUDE

DTID 3905 “Calcium Scoring Results”

1

UC

IF the value of $AnalysisPerformed equals (122605, DCM, "Vascular Morphological Analysis")

8

>>

CONTAINS

CONTAINER

EV (121070, DCM, "Findings")

1-n

U

9

>>>

HAS CONCEPT MOD

CODE

EV (125101, DCM, "Vessel Branch")

1-n

UC

IF concept value of row 4 is not equal to (T-43000, SRT, "Coronary Artery Structure")

DCID 12117 “Vessel Branch Modifiers”

10

>>>

HAS CONCEPT MOD

CODE

EV (G-A1F8, SRT, "Topographical Modifier")

1

UC

IF concept value of row 4 is not equal to (T-43000, SRT, "Coronary Artery Structure")

DCID 12116 “Vessel Segment Modifiers”

11

>>>

HAS CONCEPT MOD

CODE

EV (G-A1F8, SRT, "Topographical Modifier")

1

UC

IF concept value of row 4 equals (T-43000, SRT, "Coronary Artery Structure")

DCID 3019 “Cardiovascular Anatomic Location Modifiers”

12

>>>

CONTAINS

INCLUDE

DTID 3907 “Vessel Measurements”

1

U

13

>>>

CONTAINS

INCLUDE

DTID 3908 “Vascular Lesion”

1-n

UC

IF the value of$AnalysisPerformed equals (122605, DCM, "Vascular Morphological Analysis")

14

>>>

CONTAINS

INCLUDE

DTID 3910 “Flow Quantification”

1

UC

IF the value of$AnalysisPerformed equals (122606, DCM, "Vascular Functional Analysis")


Content Item Descriptions

Row 3

This Findings container allows an application to group related vessels or branches

Row 5

The characteristics associated with the parent vessel shall also be reported in the findings Container for the parent vessel. Negative findings (characteristics not present) need not be reported in the parent vessel Container.

DICOM PS3.16 2019a - Content Mapping Resource