DICOM PS3.16 2020c - Content Mapping Resource

TID 3806 Cath Procedure

This Template describes the patient-related information about this specific clinical encounter (catheterization).

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3806. Cath Procedure

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (55111-9, LN, "Current Procedure Descriptions")

1

M

2

>

CONTAINS

DATETIME

EV (52, NCDR [2.0b], "Procedure DateTime")

1

M

3

>

CONTAINS

TEXT

EV (53, NCDR [2.0b], "Procedure Number in this admission")

1

U

Up to three numeric characters

4

>

CONTAINS

TEXT

EV (121065, DCM, "Procedure Description")

1

U

5

>

CONTAINS

COMPOSITE

EV (121120, DCM, "Cath Lab Procedure Log")

1-n

U

6

>

CONTAINS

NUM

EV (55, NCDR [2.0b], "Fluoroscopy Time")

1

U

UNITS = DT (min, UCUM, "min")

7

>

CONTAINS

NUM

EV (122130, DCM, "Dose Area Product")

1

U

UNITS = DT (mGy.cm2, UCUM, "mGy.cm2")

8

>

CONTAINS

PNAME

EV (76, NCDR [2.0b], "Catheterization Operator")

1

M

9

>

CONTAINS

PNAME

EV (121088, DCM, "Fellow")

1-n

U

10

>

CONTAINS

PNAME

BCID 7453 “Performing Roles”

1-n

U

11

>

CONTAINS

CODE

EV (122129, DCM, "PCI during this procedure")

1

U

DCID 230 “Yes-No”

12

>

CONTAINS

CONTAINER

EV (182833002, SCT, "Medication Given")

1

M

13

>>

CONTAINS

CODE

EV (57, NCDR [2.0b], "Thrombolytics")

1

U

DCID 3740 “Thrombolytic Administration”

14

>>

CONTAINS

CODE

EV (58, NCDR [2.0b], "IIb/IIIa Blockade")

1

U

DCID 3741 “Medication Administration, Lab Visit”

15

>>

CONTAINS

CODE

EV (59, NCDR [2.0b], "Heparin")

1-n

U

DCID 3742 “Medication Administration, PCI”

16

>>

CONTAINS

CODE

EV (60, NCDR [2.0b], "Aspirin")

1

U

DCID 3741 “Medication Administration, Lab Visit”

17

>>

CONTAINS

CODE

EV (61, NCDR [2.0b], "Clopidogrel/Ticlopidine")

1

U

DCID 3743 “Clopidogrel/Ticlopidine Administration”

18

>>

CONTAINS

TEXT

EV (122083, DCM, "Drug administered")

1-n

U

19

>

CONTAINS

CODE

EV (122138, DCM, "Circulatory Support")

1-n

U

DCID 3553 “Circulatory Support”

20

>

CONTAINS

CODE

EV (74, NCDR [2.0b], "Percutaneous Entry Site")

1

M

DCID 3746 “Percutaneous Entry Site”

21

>

CONTAINS

CODE

EV (75, NCDR [2.0b], "Closure Device")

1

U

DCID 3747 “Percutaneous Closure”


Content Item Descriptions

Row 3

Procedure Number (this admission) is specified as a numeric text string, and shall be treated as the ordinal of this catheterization procedure within the admission (i.e., "1" for the first catheterization, "2" for the second, etc.).

DICOM PS3.16 2020c - Content Mapping Resource