DICOM PS3.16 2020b - Content Mapping Resource

TID 3803 Patient Presentation, Cath

This Template describes the aspects of the patient that are specific to this clinical presentation (admission).

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3803. Patient Presentation, Cath

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (55108-5, LN, "Patient Presentation")

1

M

2

>

CONTAINS

TEXT

EV (122128, DCM, "Patient Transferred From")

1

U

3

>

CONTAINS

DATETIME

EV (15, NCDR [2.0b], "Admission DateTime")

1

U

4

>

CONTAINS

CODE

EV (17, NCDR [2.0b], "Admission Status")

1

U

DCID 3729 “Admission Status”

5

>

CONTAINS

CODE

EV (18, NCDR [2.0b], "Insurance Payor Type")

1

U

DCID 3730 “Insurance Payor”

6

>

CONTAINS

CODE

EV (46, NCDR [2.0b], "Congestive Heart Failure Prior to Procedure")

1

U

DCID 230 “Yes-No”

7

>

CONTAINS

CODE

EV (47, NCDR [2.0b], "NYHA Classification")

1

UC

IFF Row 6 Value code meaning is <yes>

DCID 3736 “NYHA Classification”

8

>

CONTAINS

CODE

EV (48, NCDR [2.0b], "Noninvasive Testing - Ischemia")

1

U

DCID 3737 “Non-invasive Test - Ischemia”

9

>

CONTAINS

CODE

EV (49, NCDR [2.0b], "Pre-Cath Angina Type")

1

U

DCID 3738 “Pre-Cath Angina Type”

10

>

CONTAINS

CODE

EV (50, NCDR [2.0b], "Pre-Cath Canadian Classification")

1

U

DCID 3719 “Canadian Clinical Classification”

11

>

CONTAINS

CODE

EV (51, NCDR [2.0b], "Acute Coronary Syndrome Time Period")

1

UC

IFF Row 9 Value code meaning is <ACS>

DCID 3735 “Acute Coronary Syndrome Time Period”

12

>

CONTAINS

CONTAINER

EV (18785-6, LN, "Indications for Procedure")

1

U

13

>>

CONTAINS

CODE

EV (121071, DCM, "Finding")

1-n

U

DCID 3727 “Indications for Catheterization”

14

>

CONTAINS

NUM

EV (10230-1, LN, "LV Ejection Fraction")

1-n

U

UNITS = EV (%, UCUM, "%")

15

>>

HAS CONCEPT MOD

CODE

EV (370129005, SCT, "Measurement method")

1

U

DCID 3744 “EF Testing Method”

16

>>

INCLUDE

DTID 1000 “Quotation”

1

U

17

>

CONTAINS

CODE

EV (121069, DCM, "Previous Finding")

1-n

U

DCID 3700 “Cath Diagnosis”

18

>

CONTAINS

TEXT

EV (55108-5, LN, "Patient Presentation")

1

U


DICOM PS3.16 2020b - Content Mapping Resource