1
|
|
|
CONTAINER
|
EV (11329-0, LN, "History")
|
1
|
M
|
|
|
2
|
>
|
CONTAINS
|
TEXT
|
EV (11329-0, LN, "History")
|
1
|
U
|
|
|
3
|
>
|
CONTAINS
|
CONTAINER
|
DT (11450-4, LN, "Problem List")
|
1
|
U
|
|
|
4
|
>>
|
CONTAINS
|
TEXT
|
DCID 3769 “Concern Types”
|
1-n
|
U
|
|
|
5
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1-n
|
U
|
|
$Problem = DCID 3756 “Cardiac Patient Risk Factors”
|
6
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1
|
U
|
|
$Problem = EV (G-023F, SRT, "History of Diabetes mellitus")
$Therapy = DCID 3722 “Diabetic Therapy”
|
7
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1
|
U
|
|
$Problem = EV (G-0269, SRT, "History of Hypertension")
$Therapy = DCID 3760 “Hypertension Therapy”
|
8
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1
|
U
|
|
$Problem = EV (R-102B8, SRT, "History of Hypercholesterolemia")
$Therapy = DCID 3761 “Antilipemic Agents”
|
9
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1
|
U
|
|
$Problem = EV (D3-30000, SRT, "Arrhythmia")
$Therapy = DCID 3762 “Antiarrhythmic Agents”
|
10
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1
|
U
|
|
$Problem = EV (G-03AA, SRT, "History of Myocardial infarction")
$ModType = DT (122170, DCM, "Type of Myocardial Infarction")
$ModValue = DCID 3723 “MI Types”
$Therapy = DCID 3764 “Myocardial Infarction Therapies”
|
11
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3829 “Problem Properties”
|
1
|
U
|
|
$Problem = EV (G-0069, SRT, "History of Kidney disease")
$Stage = DCID 3778 “Stages”
|
12
|
>
|
CONTAINS
|
CONTAINER
|
DT (29762-2, LN, "Social History")
|
1
|
U
|
|
|
13
|
>>
|
CONTAINS
|
TEXT
|
EV (F-02455, SRT, "Social History")
|
1
|
U
|
|
|
14
|
>>
|
CONTAINS
|
TEXT
|
DCID 3774 “Social History”
|
1-n
|
U
|
|
|
15
|
>>
|
CONTAINS
|
CODE
|
EV (F-93109, SRT, "Tobacco Smoking Behavior")
|
1
|
U
|
|
DCID 3724 “Smoking History”
|
16
|
>>
|
CONTAINS
|
CODE
|
DT (F-931D4, SRT, "Drug misuse behavior")
|
1
|
U
|
|
DT (D9-30400, SRT, "Cocaine Abuse")
|
17
|
>
|
CONTAINS
|
CONTAINER
|
DT (10167-5, LN, "Past Surgical History")
|
1
|
U
|
|
|
18
|
>>
|
CONTAINS
|
TEXT
|
EV (11329-0, LN, "History")
|
1-n
|
U
|
|
|
19
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3830 “Procedure Properties”
|
1-n
|
U
|
|
$ProcType = DT (P0-009C3, SRT, "Surgical Procedure")
$Procedure = DCID 3721 “Cardiovascular Surgeries”
|
20
|
>
|
CONTAINS
|
CONTAINER
|
DT (30954-2, LN, "Relevant Diagnostic Tests and/or Laboratory Data")
|
1
|
U
|
|
|
21
|
>>
|
CONTAINS
|
TEXT
|
EV (11329-0, LN, "History")
|
1-n
|
U
|
|
|
22
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3830 “Procedure Properties”
|
1-n
|
U
|
|
$ProcType = DT (P0-00002, SRT, "Diagnostic procedure")
$Procedure = DCID 3757 “Cardiac Diagnostic Procedures”
|
23
|
>>
|
CONTAINS
|
NUM
|
DT (2086-7, LN, "Cholesterol.in HDL")
|
1
|
U
|
|
UNITS = EV (mg/dl, UCUM, "mg/dl")
|
24
|
>>
|
CONTAINS
|
NUM
|
DT (2089-1, LN, "Cholesterol.in LDL")
|
1
|
U
|
|
UNITS = EV (mg/dl, UCUM, "mg/dl")
|
25
|
>
|
CONTAINS
|
CONTAINER
|
DT (10160-0, LN, "History of Medication Use")
|
1
|
U
|
|
|
26
|
>>
|
CONTAINS
|
TEXT
|
DT (111516, DCM, "Medication Type")
|
1-n
|
U
|
|
|
27
|
>>>
|
HAS PROPERTIES
|
CODE
|
DT (33999-4, LN, "Status")
|
1
|
U
|
|
DCID 3773 “Use Status”
|
28
|
>>
|
CONTAINS
|
CODE
|
DT (111516, DCM, "Medication Type")
|
1-n
|
U
|
|
|
29
|
>>>
|
HAS PROPERTIES
|
NUM
|
DT (G-C0B7, SRT, "Dosage")
|
1
|
U
|
|
|
30
|
>>>
|
HAS PROPERTIES
|
CODE
|
DT (33999-4, LN, "Status")
|
1
|
U
|
|
DCID 3773 “Use Status”
|
31
|
>
|
CONTAINS
|
CONTAINER
|
DT (10157-6, LN, "History of Family Member Diseases")
|
1
|
U
|
|
|
32
|
>>
|
CONTAINS
|
TEXT
|
EV (11329-0, LN, "History")
|
1-n
|
U
|
|
|
33
|
>>
|
CONTAINS
|
CODE
|
EV (G-03E5, SRT, "Family history of clinical finding")
|
1-n
|
U
|
|
DCID 3758 “Cardiovascular Family History”
|
34
|
>>>
|
HAS PROPERTIES
|
CODE
|
EV (G-C32E, SRT, "Subject relationship")
|
1
|
M
|
|
DCID 7451 “Family Member”
|
35
|
>
|
CONTAINS
|
CONTAINER
|
DT (46264-8, LN, "History of medical device use")
|
1
|
U
|
|
|
36
|
>>
|
CONTAINS
|
TEXT
|
EV (11329-0, LN, "History")
|
1
|
U
|
|
|
37
|
>>
|
CONTAINS
|
INCLUDE
|
DTID 3831 “Medical Device Use”
|
1-n
|
U
|
|
$Device = DCID 3777 “Implanted Devices”
|