DICOM PS3.16 2019a - Content Mapping Resource

TID 3219 Segment Values

The Segment Values Template consists of Content Items providing quantitative arterial analysis measurements for a total analyzed segment or sub segment.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3219. Segment Values

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (122510, DCM, "Length Luminal Segment")

$Unit = DT (mm, UCUM, "mm")

2

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (G-0364, SRT, "Vessel Luminal Diameter")

$Derivation = EV (R-404FB, SRT, "Minimum")

$Unit = DT (mm, UCUM, "mm")

3

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (G-0364, SRT, "Vessel Luminal Diameter")

$Derivation = EV (G-A437, SRT, "Maximum")

$Unit = DT (mm, UCUM, "mm")

4

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

M

$Measurement = EV (G-0364, SRT, "Vessel Luminal Diameter")

$Derivation = EV (R-00317, SRT, "Mean")

$Unit = DT (mm, UCUM, "mm")

5

CONTAINS

INCLUDE

DTID 300 “Measurement”

1

U

$Measurement = EV (G-0364, SRT, "Vessel Luminal Diameter")

$Derivation = EV (R-10047, SRT, "Standard Deviation")

$Unit = DT (mm, UCUM, "mm")


Content Item Descriptions

Row 1

Measured along the midline of the left and right contour.