DICOM PS3.16 2020c - Content Mapping Resource

TID 3100 Procedure Action

The Procedure Action Template is intended for the recording of the beginning or end of procedure steps or action items in a procedure. The level of granularity of the recorded events is not specified, and may vary between institutions, or even be at multiple levels within a single procedure log. There is no requirement for the real-world procedure step or action item recorded with this Template to end before another one begins; there may be overlapping or simultaneous procedure steps or action items.

This log entry Template may be used to record the start or stop of timers.

Other recorded events in the procedure may be linked to a particular step or action item by Procedure Action ID (see TID 3010 “Log Entry Qualifiers”).

Type:

Extensible

Order:

Significant

Root:

No

Table TID 3100. Procedure Action

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CODE

DCID 3421 “Procedure Action”

1

M

BCID 3405 “Procedure Action Values”

2

>

HAS PROPERTIES

TEXT

EV (121124, DCM, "Procedure Action ID")

1

M

3

>

HAS PROPERTIES

PNAME

BCID 7453 “Performing Roles”

1-n

U

4

>

HAS PROPERTIES

NUM

EV (121128, DCM, "Procedure Action Duration")

1

U

5

>

INCLUDE

DTID 3010 “Log Entry Qualifiers”

1

U

6

>

HAS PROPERTIES

UIDREF

EV (121126, DCM, "Performed Procedure Step SOP Instance UID")

1

MC

IFF a Performed Procedure Step SOP Class is used to provide status of the Procedure Step

7

>

HAS PROPERTIES

UIDREF

EV (121127, DCM, "Performed Procedure Step SOP Class UID")

1

MC

IFF a Performed Procedure Step SOP Class is used to provide status of the Procedure Step


Content Item Descriptions

Row 2

The value of the Procedure Action ID shall be uniquely associated with the step or action within the context of the Study, and may be used to associate various Procedure Log entries with the step or action.

Row 3

May be used to record the identity of staff roles for the purpose of this Procedure Action, which may differ from their roles in the procedure as a whole.

DICOM PS3.16 2020c - Content Mapping Resource