DICOM PS3.16 2020b - Content Mapping Resource

TID 10034 Radiation Dose Estimate Parameters

This template includes the parameters that are specific to the Radiation Dose Estimate Method used in the algorithms when estimating dose to individual organs, phantoms, or the entire body from imaging studies that use ionizing radiation.

Type:

Extensible

Order:

Non-Significant

Root:

No

Table TID 10034. Radiation Dose Estimate Parameters

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (128434, DCM, "Radiation Dose Estimate Parameters")

1

M

2

>

CONTAINS

NUM

DCID 10069 “Radiation Dose Estimation Parameter ”

1-n

MC

IF Row 4 absent

UNITS = DCID 82 “Units of Measurement”

4

>

CONTAINS

COMPOSITE

EV (128436, DCM, "Radiation Dose Composite Parameters")

1-n

MC

IF Row 2 absent

5

>>

CONTAINS

TEXT

EV (121106, DCM, "Comment")

1

U


Content Item Descriptions

Row 2

These are the parameters of the method specified in Row 43 of TID 10033 “Radiation Dose Estimate Methodology”.

The code meanings should correlate directly with the names of the parameters used in the methodology documentation.

Row 4

References to Parametric Map Image, Mesh, encapsulated pdf, or other similar IOD.

Row 5

Describes the contents of the IOD referenced in Row 4

DICOM PS3.16 2020b - Content Mapping Resource