DICOM PS3.16 2020c - Content Mapping Resource

TID 10024 Imaging Agent Administration Patient Characteristics

This Template describes the characteristics of the patient that are specific to the current clinical presentation (visit). In the case of radiopharmaceuticals, the characteristics noted may affect the activity received, and how dose is calculated for the patient. Patient Characteristic concepts in this Template, which may replicate attributes in the Patient Study Module, are included here as possible targets of by-reference relationships from other Content Items in the SR tree.

Type:

Extensible

Order:

Significant

Root:

No

Table TID 10024. Imaging Agent Administration Patient Characteristics

NL

Rel with Parent

VT

Concept Name

VM

Req Type

Condition

Value Set Constraint

1

CONTAINER

EV (121118, DCM, "Patient Characteristics")

2

>

CONTAINS

CODE

EV (109054, DCM, "Patient state")

1-n

U

DCID 10045 “Radiopharmaceutical Patient State”

DCID 64 “Imaging Agent Administration Patient State”

3

>

CONTAINS

NUM

EV (121033, DCM, "Subject Age")

1

U

UNITS = DCID 7456 “Units of Measure for Age”

4

>

CONTAINS

CODE

EV (121032, DCM, "Subject Sex")

1

U

DCID 7455 “Sex”

5

>

CONTAINS

NUM

EV (8302-2, LN, "Patient Height")

1

U

UNITS = EV (cm, UCUM, "cm")

6

>

CONTAINS

NUM

EV (29463-7, LN, "Patient Weight")

1

U

UNITS = EV (kg, UCUM, "kg").

7

>

CONTAINS

NUM

EV (8277-6, LN, "Body Surface Area")

1

U

UNITS = EV (m2, UCUM, "m^2")

8

>>

INFERRED FROM

CODE

EV (8278-4, LN, "Body Surface Area Formula")

1

U

BCID 3663 “Body Surface Area Equations”

9

>

CONTAINS

NUM

EV (60621009, SCT, "Body Mass Index")

1

U

UNITS = EV (kg/m2, UCUM, "kg/m^2")

10

>>

INFERRED FROM

CODE

EV (121420, DCM, "Equation")

1

U

DT (122265, DCM, "BMI = Wt/Ht^2")

11

>

CONTAINS

NUM

EV (14749-6, LN, "Glucose")

1

U

UNITS = EV (mmol/l, UCUM, "mmol/l")

12

>

CONTAINS

NUM

EV(113550, DCM, "Fasting Duration")

1

U

UNITS = DT (h, UCUM, "hours")

13

>

CONTAINS

NUM

EV(113551, DCM, "Hydration Volume")

1

U

UNITS = DT (ml, UCUM, "ml")

14

>

CONTAINS

TEXT

EV (113552, DCM, "Recent Physical Activity")

1

U

15

>

CONTAINS

NUM

EV (2160-0, LN, "Serum Creatinine")

1

U

UNITS = DT (mg/dl, UCUM, "mg/dl")

16

>

CONTAINS

NUM

EV (80274001, SCT, "Glomerular Filtration Rate")

1-n

U

UNITS = DT (ml/min{1.73_m2}, UCUM, "ml/min/1.73m2")

17

>>

HAS CONCEPT MOD

CODE

EV (370129005, SCT, "Measurement Method")

1

U

DCID 10047 “GFR Measurement Methods”

18

>>

HAS CONCEPT MOD

CODE

EV (121050, DCM, "Equivalent meaning of concept name")

1

M

DCID 10046 “GFR Measurements”


Content Item Descriptions

Row 3

Defaults to value of Patient's Age (0010,1010) in Patient Study Module

Row 5

Patient height may differ from Patient's Size (0010,1020). Row 4 is the height value used for any height based protocols.

Observation DateTime (0040,A032) may be used to record when the measurement was taken.

Row 6

Patient weight may differ from Patient's Weight (0010,1030). Row 5 is the weight value used for any weight based protocols.

Observation DateTime (0040,A032) shall be used to record when the measurement was taken.

Row 11

Patient's Blood Glucose level.

Observation DateTime (0040,A032) shall be used to record when the measurement was taken.

Row 15

Serum Creatinine level.

Observation DateTime (0040,A032) shall be used to record when the measurement was taken.

Row 16

Glomerular Filtration Rate Observation DateTime (0040,A032) shall be used to record when the measurement was taken.

The formatting of the UCUM units is aligned with LOINC. See http://unitsofmeasure.org/trac/ticket/98

DICOM PS3.16 2020c - Content Mapping Resource