DICOM PS3.16 2019a - Content Mapping Resource

CID 7304 Implant Target Anatomy

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20170914

UID:

1.2.840.10008.6.1.1035

Table CID 7304. Implant Target Anatomy

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-CT Concept ID

UMLS Concept Unique ID

SRT

T-15750

Ankle Joint

70258002

C0003087

SRT

T-11501

Cervical Spine

122494005

C0728985

SRT

T-D00F7

Cervico-Thoracic Spine

297171002

C0729373

SRT

T-15430

Elbow Joint

16953009

C0013770

SRT

T-11196

Facial Bones

91397008

C0015455

SRT

T-12710

Femur

71341001

C0015811

SRT

T-12711

Head of Femur

2812003

C0015813

SRT

T-D078C

Proximal Femur

310651003

C0588192

SRT

T-12717

Shaft of Femur

41111004

C0588193

SRT

T-D078D

Distal Femur

310652005

C0588194

SRT

T-15516

Finger Joint

125682004

C0016125

SRT

T-15710

Hip Joint

24136001

C0019558

SRT

T-D1213

Jaw Region

661005

C0022359

SRT

T-D9200

Knee

72696002

C0022742

SRT

T-11503

Lumbar Spine

122496007

C0024091

SRT

T-D0059

Lumbo-Sacral Spine

243898001

C0446379

SRT

T-11180

Mandible

91609006

C0024687

SRT

T-11170

Maxilla

70925003

C0024947

SRT

T-12730

Patella

64234005

C0030647

SRT

T-12310

Clavicle

51299004

C0008913

SRT

T-D2220

Shoulder

16982005

C0037004

SRT

T-12410

Humerus

85050009

C0020164

SRT

T-1240F

Proximal Humerus

119524001

C0588209

SRT

T-12412

Shaft of Humerus

20760004

C0588210

SRT

T-1241F

Distal Humerus

118495001

C0588211

SRT

T-12420

Radius

62413002

C0034627

SRT

T-1242A

Proximal Radius

12881000

C0588205

SRT

T-12423

Shaft of Radius

47728000

C0588208

SRT

T-1242B

Distal Radius

75129005

C0588207

SRT

T-12430

Ulna

23416004

C0041600

SRT

T-1243A

Proximal Ulna

34318004

C0588201

SRT

T-12435

Shaft of Ulna

21133008

C0588204

SRT

T-1243B

Distal Ulna

91238003

C0588203

SRT

T-11100

Skull

89546000

C0037303

SRT

T-12600

Hand

24097009

C0448064

SRT

T-11502

Thoracic Spine

122495006

C0581269

SRT

T-D00FA

Thoraco-Lumbar Spine

297174005

C0574026

SRT

T-15460

Wrist Joint

74670003

C1322271

SRT

T-12375

Pelvis

118645006

C0448168

SRT

T-12750

Fibula

87342007

C0016068

SRT

T-12780

Talus

67453005

C0039277

SRT

T-12770

Calcaneus

80144004

C0006655

SRT

T-12740

Tibia

12611008

C0040184

SRT

T-12746

Shaft of Tibia

52687003

C0588199

SRT

T-1274B

Distal Tibia

64605006

C0588200


Note

Consistent with other concepts in this context group that refer to specific bones or joints, the concept for Elbow has been changed from T-D8300 to T-15430 used in a prior version of this table. Although there is minimal possibility of misinterpretation with SOP Instances that may include the deprecated use, receiving applications should be aware of this change; see Annex J.