DICOM PS3.16 2019c - Content Mapping Resource

CID 6041 Mammography Image Quality Finding

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20020904

UID:

1.2.840.10008.6.1.371

Table CID 6041. Mammography Image Quality Finding

Coding Scheme Designator

Code Value

Code Meaning

Source

DCM

111177

View and Laterality Marker is missing

MQSA

DCM

111178

View and Laterality Marker does not have both view and laterality

MQCM 1999

DCM

111179

View and Laterality Marker does not have approved codes

MQCM 1999

DCM

111180

View and Laterality Marker is not near the axilla

MQCM 1999

DCM

111181

View and Laterality Marker overlaps breast tissue

MQCM 1999

DCM

111182

View and Laterality Marker is partially obscured

MQCM 1999

DCM

111183

View and Laterality Marker is incorrect

DCM

111184

View and Laterality Marker is off image

DCM

111185

Flash is not near edge of film

MQCM 1999

DCM

111186

Flash is illegible, does not fit, or is lopsided

MQSA

DCM

111187

Flash doesn't include patient name and additional patient id

MQCM 1999

DCM

111188

Flash doesn't include date of examination

MQCM 1999

DCM

111189

Flash doesn't include facility name and location

MQSA

DCM

111190

Flash doesn't include technologist identification

MQCM 1999

DCM

111191

Flash doesn't include cassette/screen/detector identification

MQCM 1999

DCM

111192

Flash doesn't include mammography unit identification

MQCM 1999

DCM

111193

Date sticker is missing

MQCM 1999

DCM

111194

Technical factors missing

MQCM 1999

DCM

111195

Collimation too close to breast

MQCM 1999

DCM

111196

Inadequate compression

MQCM 1999

DCM

111197

MLO Insufficient pectoral muscle

MQCM 1999

DCM

111198

MLO No fat is visualized posterior to fibroglandular tissues

MQCM 1999

DCM

111199

MLO Poor separation of deep and superficial breast tissues

MQCM 1999

DCM

111200

MLO Evidence of motion blur

MQCM 1999

DCM

111201

MLO Inframammary fold is not open

MQCM 1999

DCM

111202

CC Not all medial tissue visualized

MQCM 1999

DCM

111203

CC Nipple not centered on image

MQCM 1999

DCM

111204

CC Posterior nipple line does not measure within 1 cm of MLO

MQCM 1999

DCM

111205

Nipple not in profile

DCM

111206

Insufficient implant displacement incorrect

MQCM 1999

DCM

111208

Grid artifact(s)

DCM

111209

Positioning

DCM

111210

Motion blur

DCM

111211

Under exposed

DCM

111212

Over exposed

DCM

111213

No image

DCM

111214

Detector artifact(s)

DCM

111215

Artifact(s) other than grid or detector artifact

DCM

111216

Mechanical failure

DCM

111217

Electrical failure

DCM

111218

Software failure

DCM

111219

Inappropriate image processing

DCM

111220

Other failure

DCM

111221

Unknown failure


DICOM PS3.16 2019c - Content Mapping Resource