DICOM PS3.16 2019c - Content Mapping Resource

CID 4029 Dermatology Anatomic Sites

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20190118

UID:

1.2.840.10008.6.1.1268

Table CID 4029. Dermatology Anatomic Sites

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

FMA ID

ICD-11

NYU Code L

NYU Code M

NYU Code R

Mayo Code L

Mayo Code M

Mayo Code R

SCT

182329002

Anterior triangle of neck

T-D03C9

C0446459

57777

XA1NS6

41

42

41

42

SCT

28726007

Cornea

T-AA200

C0229124

58238

XA4C02

109

108

SCT

85803001

Eyelash

T-01530

C0015422

53669

105

104

105

104

SCT

279479008

Female external urethral orifice

T-81001

C0458493

85266

504

SCT

279867004

Frenulum of labia minora

T-81206

C0458840

20404

XA0565

508

SCT

280387007

Groin skin crease

T-01041

C0459399

326449

XA2XG2

519

518

SCT

386045008

Hair

T-0130A

C0018494

53667

503

SCT

41296002

Iris

T-AA500

C0022077

58235

109

108

109

108

SCT

279478000

Male external urethral orifice

T-75181

C0458492

85265

513

FMA

281534

Mucosa of dorsum of oral part of tongue

C4244787

281534

XA8YB9

157

154

FMA

281537

Mucosa of dorsum of pharyngeal part of tongue

C4244789

281537

XA0HQ3

155

152

SCT

36152006

Mucosa of floor of mouth

T-51210

C0226911

292374

XA8EY7

161

158

SCT

46353006

Mucosa of lower lip

T-52210

C0226939

59833

XA72W2

165

162

SCT

245823002

Mucosa of mandibular gingiva

T-5494D

C0447479

XA9303

163

160

SCT

245814000

Mucosa of maxillary gingiva

T-5493D

C0447470

XA6743

145

144

FMA

289677

Mucosa of oral segment of hard palate

C4242040

289677

XA4527

147

146

FMA

60031

Mucosa of palatoglossal arch

C0930720

60031

151

148

FMA

55031

Mucosa of pharynx

C0227140

55031

518

FMA

55060

Mucosa of posterior wall of oropharynx

C0926847

55060

XA8659

153

150

SCT

245831007

Mucosa of tip of tongue

T-53012

C0447488

323681

XA1WZ8

159

156

SCT

8001006

Mucosa of tongue

T-53010

C0226950

54807

XA1T19

515

SCT

18444004

Mucosa of upper lip

T-52110

C0226933

59832

XA9072

143

142

FMA

60030

Mucosa of uvula

C0930719

60030

XA2993

149

149

SCT

22740002

Nail of fifth toe

T-01625

C0222012

54356

XA3VM6

441

440

441

440

SCT

91456000

Nail of finger

T-01614

C0222001

XA0EH9

526

SCT

6194002

Nail of fourth toe

T-01624

C0222011

54353

XA6TS5

439

438

439

438

SCT

38790000

Nail of great toe

T-01621

C0222008

54344

XA1RE3

433

432

433

432

SCT

63288009

Nail of index finger

T-01616

C0222003

54332

XA40D9

329

328

329

328

SCT

44431006

Nail of little finger

T-01619

C0222006

54341

XA29K9

335

334

335

334

SCT

61366001

Nail of middle finger

T-01617

C0222004

54335

XA9YZ9

331

330

331

330

SCT

51596007

Nail of ring finger

T-01618

C0222005

54338

XA6Y59

333

332

333

332

SCT

8770002

Nail of second toe

T-01622

C0222009

54347

XA7GG3

435

434

435

434

SCT

1569005

Nail of third toe

T-01623

C0222010

54350

XA3D73

437

436

437

436

SCT

28274006

Nail of thumb

T-01615

C0222002

54329

XA5PD5

327

326

327

326

SCT

76578001

Nail of toe

T-01620

C0222007

54328

XA9E36

531

SCT

113277000

Oral mucosa

T-51300

C0026639

59660

XA1WN1

516

SCT

4019005

Posterior commissure of labium majorum

T-81230

C0227762

20401

SCT

5665001

Retina

T-AA610

C0024622

58301

509

SCT

18619003

Sclera

T-AA110

C0036410

58269

XA2AF4

111

110

111

110

SCT

39937001

Skin

T-01000

C0221911

500

SCT

75093004

Skin of abdomen

T-02480

C0222166

22988

XA6GV0

522

522

SCT

68598004

Skin of ala nasi

T-02142

C0222097

59534

XA32Q9

23

24

23

24

SCT

17957002

Skin of antecubital fossa

T-02621

C0222214

38251

XA9NE6

303

302

303

302

DCM

130305

Skin of anterior helix of ear

119

118

119

118

SCT

11584001

Skin of anterior portion of neck

T-02302

C0222131

23023

XA4QS6

60

SCT

70559009

Skin of anterior surface of forearm

T-02632

C0222217

38268

XA8ZL6

305

304

305

304

SCT

181553006

Skin of anterior surface of knee

T-0282E

C0448900

38159

XA9L17

405

404

405

404

SCT

25763004

Skin of anterior surface of lower leg

T-02831

C0222280

37837

XA33X4

407

406

407

406

SCT

61248009

Skin of anterior surface of thigh

T-02811

C0222270

37793

XA98B3

403

402

403

402

SCT

244106003

Skin of anterior surface of thorax

T-02425

C0448821

521

SCT

45981001

Skin of anterior surface of upper arm

T-02612

C0222207

38238

XA22Q1

301

300

301

300

SCT

181491009

Skin of anterior trunk

T-02408

C3698018

521a

SCT

38407007

Skin of antitragus

T-02213

C0222123

322677

XA7RR9

123

122

SCT

59112000

Skin of anus

T-02508

C0222181

28008

XA0D34

512

537

SCT

72005009

Skin of areola

T-02432

C0222151

50050

XA2JK3

207

206

207

206

SCT

699891005

Skin of axilla

R-FB4D8

C0222146

37322

XA17J1

355

354

355

354

SCT

66643007

Skin of back

T-02450

C0222155

10462

527

FMA

49943

Skin of back of trunk

C0923309

49943

521b

SCT

699893008

Skin of back of upper thoracic region

R-FB4DA

C3697168

23024

XA10L7

225

224

225

224

SCT

22180002

Skin of buttock

T-02471

C0222165

45285

XA3VA7

231

230

231

527a

230

DCM

130306

Skin of caruncle of eye

171

170

SCT

51098001

Skin of cavity of concha

T-02217

C0222127

XA8D58

125

124

125

124

SCT

36141000

Skin of cheek

T-02121

C0222085

24759

XA7MK8

13

14

13

511

14

SCT

23747009

Skin of chin

T-02155

C0222106

53658

XA2C62

35

58

36

35

517

36

SCT

29353003

Skin of clitoris

T-02523

C0222189

20168

XA4851

502

536

SCT

57726007

Skin of crus of helix

T-02218

C0222128

322323

XA9A86

117

116

117

116

SCT

244169007

Skin of digit of hand

T-D0315

C0448888

38304

XA2593

525

SCT

52876008

Skin of dorsal area of wrist

T-02641

C0278393

38286

XA0SH5

313

312

313

312

FMA

37885

Skin of dorsal part of fifth toe

C0829302

37885

431

430

431

430

FMA

37882

Skin of dorsal part of fourth toe

C0829299

37882

429

428

429

428

FMA

37873

Skin of dorsal part of great toe

C0829290

37873

423

422

423

422

FMA

38324

Skin of dorsal part of index finger

C0829711

38324

325

324

325

324

FMA

38333

Skin of dorsal part of little finger

C0829720

38333

319

318

319

318

FMA

38327

Skin of dorsal part of middle finger

C0829714

38327

323

322

323

322

FMA

38330

Skin of dorsal part of ring finger

C0829717

38330

321

320

321

320

FMA

37876

Skin of dorsal part of second toe

C0829293

37876

425

424

425

424

FMA

37879

Skin of dorsal part of third toe

C0829296

37879

427

426

427

426

FMA

38321

Skin of dorsal part of thumb

C0829708

38321

317

316

317

316

FMA

59532

Skin of dorsum of nose

C0930371

59532

XA5YP3

19

53

20

19

20

SCT

1902009

Skin of ear

T-02200

C0222110

XA6ZY6

506

SCT

2059009

Skin of ear lobule

T-02214

C0222124

XA0TW7

131

130

131

130

SCT

30598005

Skin of epigastric area

T-02481

C0222167

322773

233

233

SCT

86409001

Skin of external auditory canal

T-02219

C0222129

XA3UC1

505

SCT

60944009

Skin of external genitalia

T-02501

C0222177

XA5FG3

532

SCT

362916000

Skin of eye region

T-D149C

C1285124

508

SCT

367577003

Skin of eyebrow

T-02106

C1288306

XA1LZ5

101

100

101

100

SCT

73897004

Skin of face

T-02120

C0222084

24758

XA86S4

507

SCT

60496002

Skin of foot

T-02850

C0222289

37834

XA47V8

529b

529

529a

SCT

68698007

Skin of forehead

T-02104

C0222074

63883

XA6TR8

7

52

8

7

504

8

SCT

7991003

Skin of glans penis

T-02531

C1261043

19642

XA0MH6

511

511

SCT

63029009

Skin of gluteal fold

T-02506

C0222179

20233

XA5UE3

238

SCT

33712006

Skin of hand

T-02650

C0222224

38295

XA5R12

524b

524

524a

SCT

70762009

Skin of head

T-02100

C0205029

12166

XA20Q1

501

SCT

84607009

Skin of heel

T-02841

C0222287

XA5HK0

463

460

463

462

SCT

79313003

Skin of helix of ear

T-02202

C0222113

XA6B58

SCT

367578008

Skin of hypogastric region

T-02488

C1288307

323207

235

235

SCT

89784008

Skin of hypothenar region of palm

T-02666

C0222233

79164

XA5TQ4

343

342

343

342

DCM

130307

Skin of inferior helix of ear

119

118

DCM

130308

Skin of inferior posterior surface of the pinna

139

138

139

138

DCM

130312

Skin of infraalar groove

25

26

25

26

SCT

66288003

Skin of infraclavicular region

T-02414

C0222145

61431

203

202

203

202

SCT

39687006

Skin of inguinal region

T-02487

C0222173

326059

223

222

223

222

SCT

45591000

Skin of intertragal incisure

T-02212

C0222122

322676

XA5VK5

129

128

129

128

SCT

244097004

Skin of jawline

T-0215D

C0448804

XA8KA2

37

38

37

38

SCT

73058008

Skin of labium

T-02520

C0222184

535

SCT

128252004

Skin of labium majus

T-02527

C0222185

20464

XA59G9

SCT

128253009

Skin of labium minus

T-02528

C0222186

20465

XA0MU9

515

514

SCT

181564009

Skin of lateral aspect of ankle

T-02849

C1182496

70406

XA7AM4

415

414

415

414

SCT

35739000

Skin of lateral border of sole of foot

T-02853

C0222292

XA9Y82

461

462

461

460

SCT

37671003

Skin of lateral canthus

T-02136

C0222094

322533

XA0403

169

166

169

166

DCM

130309

Skin of lateral part of dorsum of foot

419

418

419

418

SCT

699909001

Skin of lateral part of heel

R-FB4EA

C3697424

326712

XA3R99

417

416

417

416

SCT

5272005

Skin of lateral portion of neck

T-02304

C0222133

XA2ZF0

43

44

43

44

SCT

88089004

Skin of lips

T-02150

C0222101

24764

XA8JD4

512

SCT

699914002

Skin of lower abdomen

R-FB4EF

C3698018

221

220

221

220

SCT

699914002

Skin of lower abdomen

R-FB4EF

C3698018

603

602

DCM

130310

Skin of lower antihelix of ear

123

122

SCT

113182001

Skin of lower back

T-02452

C0222157

322763

XA9ET2

229

228

229

228

SCT

699915001

Skin of lower chest wall

R-FB4F0

C3698074

217

216

217

216

SCT

371304004

Skin of lower extremity

T-0262C

C1266887

74665l

XA45A6

528b

528

528a

SCT

40069000

Skin of lower eyelid

T-02132

C0222090

24762

XA0JV9

115

114

115

114

DCM

130311

Skin of lower eyelid margin

XA0JV9

113

112

113

112

FMA

61427

Skin of lower inner quadrant of breast

C2363131

61427

XA0VX8

213

212

213

212

SCT

66934001

Skin of lower lip

T-02152

C0222103

24767

XA5VD0

FMA

61423

Skin of lower outer quadrant of breast

C2363133

61423

XA94U2

215

214

215

214

DCM

130304

Skin of lower paraspinal region

XA7ZW8

236

SCT

181563003

Skin of medial aspect of ankle

T-02848

C0448930

38134

XA7P78

443

442

443

SCT

52953006

Skin of medial border of sole of foot

T-02854

C0222293

XA3WM8

459

458

459

458

SCT

27887005

Skin of medial canthus

T-02135

C0222093

322532

XA2GQ3

167

164

167

164

DCM

130313

Skin of medial part of dorsum of foot

421

420

421

420

SCT

699919007

Skin of medial part of heel

R-FB4F4

C3698118

326720

XA1QH8

445

444

445

444

SCT

73958006

Skin of medial surface of thigh

T-02814

C0222273

XA1YQ6

401

400

401

400

DCM

130323

Skin of mid back

227

226

227

226

DCM

130303

Skin of mid paraspinal region

234

SCT

37108007

Skin of nasolabial fold

T-02141

C0222096

322319

27

28

27

28

SCT

43081002

Skin of neck

T-02300

C0205030

23021

XA7AA6

519

SCT

54468004

Skin of nipple

T-02431

C0222150

12828

XA5MC5

205

204

205

204

SCT

113179006

Skin of nose

T-02140

C0222095

24763

XA3H13

510

SCT

4658004

Skin of nuchal region

T-02305

C0222134

23020

XA1M78

45

46

45

46

SCT

79951008

Skin of occipital region

T-02109

C0222078

24773

XA7JE5

1

61

2

1

2

SCT

70887009

Skin of palm of hand

T-02652

C0222226

38301

XA3NY8

341

340

341

340

SCT

24527008

Skin of palmar area of wrist

T-02642

C0278394

38283

XA6AR5

337

336

337

336

FMA

38344

Skin of palmar part of index finger

C0829728

38344

347

346

347

346

FMA

38357

Skin of palmar part of little finger

C0829738

38357

353

352

353

352

FMA

38347

Skin of palmar part of middle finger

C0829731

38347

349

348

349

348

FMA

38354

Skin of palmar part of ring finger

C0829735

38354

351

350

351

350

FMA

38341

Skin of palmar part of thumb

C0829725

38341

345

344

345

344

DCM

130314

Skin of paranasal cheek

XA3ZL3

15

16

15

16

DCM

130300

Skin of paraspinal area of the neck

62

DCM

130301

Skin of paraspinal area of the superior back

63

SCT

21672008

Skin of parietal region

T-02108

C0222077

XA4W34

3

4

3

4

SCT

281642007

Skin of part of dorsal surface of hand

T-0265D

C0559541

XA30Z6

315

314

315

314

SCT

35900000

Skin of penis

T-02530

C0222193

19638

XA7QV2

533

SCT

48014002

Skin of perineum

T-02500

C0222176

20429

510

SCT

110488009

Skin of perioral region of face

T-02148

C1266883

59354

XA1A48

513

SCT

84365009

Skin of philtrum

T-02153

C0222104

59377

XA5LY8

55

FMA

38119

Skin of plantar part of fifth toe

C0829534

38119

455

454

455

454

FMA

38116

Skin of plantar part of fourth toe

C0829531

38116

453

452

453

452

FMA

38107

Skin of plantar part of great toe

C0829522

38107

447

446

447

446

FMA

38110

Skin of plantar part of second toe

C0829525

38110

449

448

449

448

FMA

38113

Skin of plantar part of third toe

C0829528

38113

451

450

451

450

SCT

84507004

Skin of popliteal fossa

T-02821

C0222276

38162

XA4DM3

411

410

411

410

SCT

24483006

Skin of postauricular region

T-02113

C0222082

XA4DV9

9

10

9

10

DCM

130315

Skin of posterior helix of ear

135

134

135

134

DCM

130316

Skin of posterior lobule of the ear

141

140

141

140

SCT

181536004

Skin of posterior surface of elbow

T-D077A

C0448862

XA3RT8

309

308

309

308

SCT

41550009

Skin of posterior surface of forearm

T-02631

C0222216

38271

XA8WH0

311

310

311

310

SCT

47224004

Skin of posterior surface of lower leg

T-02833

C0222282

37840

XA4K86

413

412

412

413

SCT

4578000

Skin of posterior surface of thigh

T-02812

C0222271

37797

XA0183

409

408

409

408

SCT

244111001

Skin of posterior surface of thorax

T-0242A

C0448820

74762

XA10L7

49

50

49

50

SCT

72939005

Skin of posterior surface of upper arm

T-02613

C0222208

38241

XA5TK8

307

306

307

306

SCT

86719006

Skin of preauricular region

T-02114

C0222083

XA0SU2

11

12

11

12

SCT

76723005

Skin of prepuce of clitoris

T-02525

C0222191

27886

XA3C45

500

SCT

244117002

Skin of root of penis

T-02536

C0447599

322351

XA0970

501

SCT

43067004

Skin of scalp

T-02102

C0699772

24757

XA6CW5

502

SCT

81992007

Skin of scrotum

T-02545

C0222198

20432

XA8MT4

505

503

534

534

SCT

244118007

Skin of shaft of penis

T-02537

C0447600

19643

XA9A26

507

SCT

244089006

Skin of side of nose

T-0214D

C0448800

322330

XA9JN5

17

18

17

18

DCM

130317

Skin of sole of forefoot

XA6KE9

457

456

457

456

SCT

34926004

Skin of submental area

T-02156

C0222107

XA5TZ1

59

DCM

130318

Skin of superior antihelix of ear

121

120

DCM

130319

Skin of superior posterior helix of ear

133

132

133

132

DCM

130320

Skin of superior posterior surface of the pinna

137

136

137

136

SCT

76072005

Skin of supraclavicular region of neck

T-02306

C0222135

XA9DQ5

47

48

47

48

SCT

48670002

Skin of supraorbital area

T-02105

C0222075

XA5WP1

103

102

SCT

16621002

Skin of temporal region

T-02111

C0222080

320486

XA9DZ0

5

6

5

6

SCT

26795005

Skin of thenar region of palm

T-02665

C0222232

79164

XA2JN4

339

338

339

338

SCT

79283007

Skin of tip of nose

T-02143

C0222098

59533

XA56T3

21

54

22

21

22

SCT

52034004

Skin of toe

T-02870

C0222297

37852

XA4LC9

530

SCT

79502000

Skin of tragus

T-02211

C0222121

322671

XA2N71

127

126

127

126

SCT

315003

Skin of umbilicus

T-02483

C0222169

74803

XA3MT9

200

200

SCT

699935000

Skin of upper abdomen

R-FB504

C3696900

219

218

219

218

SCT

699935000

Skin of upper abdomen

R-FB504

C3696900

601

600

DCM

130321

Skin of upper antihelix of ear

121

120

SCT

371311000

Skin of upper extremity

T-02008

C0222201

XA4BA8

523b

523

523a

SCT

41310005

Skin of upper eyelid

T-02131

C0222089

24761

XA9K79

105

104

103

104

DCM

130322

Skin of upper eyelid margin

XA53T1

107

106

107

106

FMA

61426

Skin of upper inner quadrant of breast

C2363130

61426

XA3LS6

211

210

211

210

SCT

16251004

Skin of upper lip

T-02151

C0222102

24765

XA0K68

29

30

29

30

FMA

61439

Skin of upper outer quadrant of left breast

C0931805

61439

XA2Q54

209

208

209

208

DCM

130302

Skin of upper paraspinal region

232

232

SCT

54440003

Skin of upper trunk

T-02401

C0222138

XA4QH7

520

FMA

312651

Skin of vermilion proper of lower lip

C4242687

312651

XA7H02

33

57

34

33

34

FMA

312647

Skin of vermilion proper of upper lip

C4242681

312647

XA75S0

31

56

32

31

32

SCT

61719002

Skin of vertex of scalp

T-02107

C0222076

XA5BY6

51

SCT

244107007

Sternal skin

T-02426

C0448823

201

201

SCT

5713008

Submandibular triangle

T-D1603

C0230070

57779

XA0MP5

39

40

39

40

SCT

38199008

Tooth

T-54010

C0040426

12516

514

SCT

18857001

Vaginal introitus

T-82006

C0458952

19984

XA4AH3

506

SCT

23213005

Vulval vestibule

T-81270

C0227765

19970

516


Note

  1. It is desirable to use more general standard coding schemes such as SNOMED CT whenever possible, to support interoperability across specialist domains, yet the numeric codes from the NYU and Mayo systems are well known to dermatologists. Multiple codes may be encoded in the image by using the equivalent code mechansism. See 8.9 “Equivalent Code Sequence”. Standard Coding Scheme Designators (NYUMCCG and MAYOASRG) are defined.

  2. SNOMED CT and FMA "skin of" or "mucosa of" specific concepts are used here when available, rather than the more generic underlying organ or part concepts; this sacrifices commonality with the anatomic regions used for more general applications, but is appropriate for dermatologic applications. E.g., (59112000, SCT, "Skin of anus") is used instead of (53505006, SCT, "Anal structure").

  3. The DICOM convention is to use "structure of" concepts rather than "entire" concepts when both are defined, and that convention is followed here. E.g., (37671003, SCT, "Skin structure of lateral canthus") is used in preference to (368772009, SCT "Entire skin of lateral canthus").

  4. The illustrations of the NYU anatomy identify two separately numbered structures associated with the female urethral orifice; it is not clear what separate structure is identified (perhaps Skene's Glands (71648, FMA, "Lesser vestibular glands") , but in the absence of further information, it is assumed that NYUMCCG:504 refers to the urethral orifice and NYUMCCG:517 is ignored (i.e., not included in this Context Group).

  5. The illustrations of the NYU anatomy use female genitalia to show the genitocrural fold, but it is believed that the intent is to identify the region irrespective of sex, so (280387007, SCT, "Groin skin crease") is used rather than (87706001, SCT, "Skin of crurovulvar fold").

  6. There is some uncertainty regarding the distinction between the antitragus and the intertragal incisure and whether the latter is represented at all in the NYU and Mayo drawings. The more recent mapping decision of Kenneweg et al has been adopted here, even though the text meaning differs from that for the NYU and Mayo schemes.

  7. There is some uncertainty regarding the distinction between the skin of the forehead and the frontal region of the scalp; (68698007, SCT, "Skin of forehead") is used rather than (699900002, SCT, "Skin of frontal region of scalp") , even though the later would be more consistent with the other scalp regions (parietal, temporal and occipital).

  8. Laterality is pre-coordinated in most of the NYU and Mayo codes, but by convention is factored out and encoded seperately in DICOM. The appropriate modifiers are listed in CID 245 “Laterality with Median”. The left and right modifiers correspond to the NYU/Mayo columns labelled "L" and "R" in this context group table. An entry in the "M" column of this table means that the NYU or Mayo code is for a midline or unpaired structure or refers to the median part of a structure that spans from left to right.

DICOM PS3.16 2019c - Content Mapping Resource