DICOM PS3.16 2021d - Content Mapping Resource

CID 3728 Cath Findings

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20160314

UID:

1.2.840.10008.6.1.228

Table CID 3728. Cath Findings

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

SCT

371856001

Normal left heart hemodynamics

R-0033F

C1299331

SCT

371859008

Normal right heart hemodynamics

R-00342

C1299334

SCT

371858000

Normal left and right heart hemodynamics

R-0033E

C1299333

SCT

371857005

Normal left ventricular systolic function and wall motion

R-00340

C1299332

SCT

371860003

Normal coronary arteries

R-0033D

C1299335

SCT

371861004

Mild intimal coronary irregularities, no significant stenoses

R-00328

C1299336

SCT

194842008

Single vessel coronary artery disease.

D3-13001

C0581374

SCT

194843003

Double vessel coronary artery disease.

D3-13013

C0581375

SCT

233817007

Triple vessel coronary artery disease.

D3-1301F

C0340285

SCT

371803003

Multi vessel coronary artery disease.

R-00334

C1299432

SCT

371804009

Left main coronary artery disease

R-00313

C1299433

SCT

371805005

Significant coronary bypass graft disease

R-00372

C1299434

SCT

60573004

Aortic stenosis

D3-29021

C0003507

SCT

194983005

Aortic insufficiency

D3-29025

C0340377

SCT

79619009

Mitral stenosis

D3-29011

C0026269

SCT

48724000

Mitral regurgitation

D3-29012

C0026266

SCT

371862006

Depression of left ventricular systolic function

R-002F3

C1299337

SCT

371813006

Acute mitral regurgitation from chordal rupture

R-002C8

C1299441

SCT

371814000

Acute mitral regurgitation from chordal dysfunction

R-002C7

C1299442

SCT

371816003

Acute mitral regurgitation from papillary muscle rupture

R-002CA

C1299444

SCT

371815004

Acute mitral regurgitation from papillary muscle dysfunction

R-002C9

C1299443

SCT

409712001

Mitral valve prolapse

D3-1081C

C0026267

SCT

399020009

Congestive cardiomyopathy

D3-20021

C0007193

SCT

45227007

Hypertrophic cardiomyopathy with obstruction

D3-23000

C0007194

SCT

195020003

Hypertrophic cardiomyopathy without obstruction

D3-20003

C0340425

SCT

64715009

Hypertensive heart disease

D3-02500

C0152105

SCT

90828009

Restrictive cardiomyopathy

D3-22100

C0007196

SCT

35304003

Pericardial tamponade

D3-90100

C0007177

SCT

85598007

Constrictive pericarditis

D3-91030

C0031048

SCT

70995007

Pulmonary hypertension

D3-40300

C0020542

SCT

70142008

Atrial septal defect

D4-31220

C0018817

SCT

30288003

Ventricular septal defect

D4-31150

C0018818

SCT

371817007

Acute ventricular septal rupture

R-002CB

C1299445

SCT

13213009

heart disease - congenital

D4-31000

C0152021


DICOM PS3.16 2021d - Content Mapping Resource