DICOM PS3.16 2021d - Content Mapping Resource

CID 3688 Electrophysiology Waveform Voltages

This Context Group consists of the codes of the hierarchies under Reference IDs MDC_ECG_ELEC_POTL and MDC_ECG_AMPL of the ISO/IEEE 11073-10102 nomenclature.

The base terms from those hierarchies are included in the table below for reference. The per lead base terms are pre-coordinated with concept discriminators for specific leads, and the code values for those pre-coordinated terms are arithmetically derived from the code values of the base terms. For the complete current list of terms and discriminator values, see the ISO/IEEE Standard. All pre-coordinated terms (measurements plus discriminators) within the identified hierarchies are part of this Context Group.

Note

  1. A prior version of this context group used codes from the SCP-ECG coding system.

  2. Codes reprinted by permission of IEEE, Copyright 2004 by IEEE. ISO/IEEE 11073-10102 available through http://standards.ieee.org/.

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20110330

UID:

1.2.840.10008.6.1.202

Table CID 3688. Electrophysiology Waveform Voltages

Coding Scheme Designator

Code Value

Code Meaning

ISO/IEEE 11073 MDC Equivalent Reference ID (Informative)

MDC

2:1024

J point Amplitude, per lead

MDC_ECG_AMPL_J

MDC

2:14848

Amplitude at 20 ms into ST segment, per lead

MDC_ECG_ELEC_POTL_ST_20

MDC

2:15104

Amplitude at 40 ms into ST segment, per lead

MDC_ECG_ELEC_POTL_ST_40

MDC

2:14336

Amplitude at 60 ms into ST segment, per lead

MDC_ECG_ELEC_POTL_ST_60

MDC

2:14592

Amplitude at 80 ms into ST segment, per lead

MDC_ECG_ELEC_POTL_ST_80

MDC

2:1280

P maximum amplitude, per lead

MDC_ECG_AMPL_P_MAX

MDC

2:1536

P minimum amplitude, per lead

MDC_ECG_AMPL_P_MIN

MDC

2:3072

P3 amplitude, per lead

MDC_ECG_AMPL_P3

MDC

2:1792

Q amplitude, per lead

MDC_ECG_AMPL_Q

MDC

2:2048

R amplitude, per lead

MDC_ECG_AMPL_R

MDC

2:12800

R1 amplitude, per lead

MDC_ECG_ELEC_POTL_R_1

MDC

2:13056

R2 amplitude, per lead

MDC_ECG_ELEC_POTL_R_2

MDC

2:13312

R3 amplitude, per lead

MDC_ECG_ELEC_POTL_R_3

MDC

2:2304

S amplitude, per lead

MDC_ECG_AMPL_S

MDC

2:13568

S1 amplitude, per lead

MDC_ECG_ELEC_POTL_S_1

MDC

2:13824

S2 amplitude, per lead

MDC_ECG_ELEC_POTL_S_2

MDC

2:14080

S3 amplitude, per lead

MDC_ECG_ELEC_POTL_S_3

MDC

2:2560

T maximum amplitude, per lead

MDC_ECG_AMPL_T_MAX

MDC

2:2816

T minimum amplitude, per lead

MDC_ECG_AMPL_T_MIN

MDC

2:768

ST amplitude, per lead

MDC_ECG_AMPL_ST


DICOM PS3.16 2021d - Content Mapping Resource