DICOM PS3.16 2019a - Content Mapping Resource

CID 12304 Echo Measured Properties

The Units column contains the proper UCUM representation of the recommended units for the measured property

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20161109

UID:

1.2.840.10008.6.1.1145

Table CID 12304. Echo Measured Properties

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-CT Concept ID

UMLS Concept Unique ID

Units

LN

20168-1

Acceleration Time

C0802983

(ms, UCUM, "ms")

LN

59130-5

Alias Velocity

C2923486

(m/s, UCUM, "m/s")

SRT

G-A160

Angle

1483009

C0205143

(deg, UCUM, "deg"

SRT

G-A166

Area

42798000

C0205146

(cm2, UCUM, "cm2")

SRT

F-31000

Blood Pressure

75367002

C0005823

(mm[Hg], UCUM, "mmHg")

SRT

F-32070

Cardiac Ejection Fraction

70822001

C0232174

(%, UCUM, "%")

LN

20217-6

Deceleration Time

C0803032

(ms, UCUM, "ms")

SRT

M-02550

Diameter

81827009

C1301886

(cm, UCUM, "cm")

LN

59120-6

dP/dt by US

C2923468

(mm[Hg]/s, UCUM, "mmHg/s")

SRT

G-D217

Interval

385673002

C1272706

(ms, UCUM, "ms")

DCM

125325

Dyssynchrony Index

(ms, UCUM, "ms")

DCM

125326

Effective Orifice Area

(cm2, UCUM, "cm2")

LN

59093-5

Epicardial Area

C2923421

(cm2, UCUM, "cm2")

DCM

125327

Excursion Distance

(cm, UCUM, "cm")

LN

59132-1

Fractional Shortening

C2923490

(%, UCUM, "%")

SRT

G-D7FE

Length

410668003

C1444754

(cm, UCUM, "cm")

SRT

G-D701

Mass

118538004

C1306372

(g, UCUM, "g")

DCM

125328

Maximum Orifice Area

(cm2, UCUM, "cm2")

SRT

F-31150

Mean Blood Pressure

6797001

C0428886

(mm[Hg], UCUM, "mmHg")

LN

20256-4

Mean Gradient [Pressure] by Doppler

C0803071

(mm[Hg], UCUM, "mmHg")

LN

20352-1

Mean Blood Velocity

C0803167

(m/s, UCUM, "m/s")

SRT

G-A194

Minor Axis

131188004

C1295724

(cm, UCUM, "cm")

LN

59099-2

Myocardial Performance Index (Tei)

C2923433

(1, UCUM, "no units")

LN

20247-3

Peak Gradient [Pressure]

C0803062

(mm[Hg], UCUM, "mmHg")

LN

34141-2

Peak Instantaneous Flow Rate

C1316604

(ml/s, UCUM, "ml/s")

DCM

125329

Peak Blood Pressure

(mm[Hg], UCUM, "mmHg")

LN

11726-7

Peak Blood Velocity

C0551845

(m/s, UCUM, "m/s")

DCM

125330

Peak Tissue Velocity

(cm/s, UCUM, "cm/s")

DCM

125331

PISA Radius

(cm, UCUM, "cm")

LN

20280-4

Pressure Half Time

C0803095

(ms, UCUM, "ms")

SRT

G-0390

Regurgitant Fraction

399301000

C1302309

(%, UCUM, "%")

DCM

125332

Regurgitation Jet Area

(cm2, UCUM, "cm2")

DCM

125333

Regurgitation Jet Width

(cm, UCUM, "cm")

LN

59090-1

Internal Dimension

C2923417

(cm, UCUM, "cm")

LN

59089-3

Thickness

C2923416

(cm, UCUM, "cm")

SRT

F-32120

Stroke Volume

90096001

C0038455

(ml, UCUM, "ml")

SRT

F-02692

Vascular Resistance

251271006

C0429119

(dyn.s/cm5, UCUM, "dyn.s/cm5")

LN

20354-7

Velocity Time Integral

C0803169

(cm, UCUM, "cm")

DCM

125334

Vena Contracta Width

(cm, UCUM, "cm")

SRT

G-D705

Volume

118565006

C0449468

(ml, UCUM, "ml")

LN

33878-0

Volume Flow Rate

C1316341

(ml/s, UCUM, "ml/s")


DICOM PS3.16 2019a - Content Mapping Resource