DICOM PS3.16 2019c - Content Mapping Resource

CID 12222 Orifice Flow Properties

Resources:

HTML | FHIR JSON | FHIR XML | IHE SVS XML

Type:

Extensible

Version:

20100317

UID:

1.2.840.10008.6.1.614

Table CID 12222. Orifice Flow Properties

Coding Scheme Designator

Code Value

Code Meaning

SNOMED-RT ID

UMLS Concept Unique ID

LN

33878-0

Volume Flow

C1316341

LN

34141-2

Peak Instantaneous Flow Rate

C1316604

SCT

399367004

Cardiovascular Orifice Area

G-038E

C1302344

SCT

399027007

Cardiovascular Orifice Diameter

G-038F

C1302176

SCT

399301000

Regurgitant Fraction

G-0390

C1302309

LN

11653-3

End Diastolic Velocity

C0551772

LN

11726-7

Peak Systolic Velocity

C0551845

LN

20352-1

Time Averaged Mean Velocity

C0803167

LN

11692-1

Time Averaged Peak Velocity

C0551811

LN

20247-3

Peak Gradient

C0803062

LN

20256-4

Mean Gradient

C0803071

LN

20354-7

Velocity Time Integral

C0803169

LN

20280-4

Pressure Half-Time

C0803095

LN

20168-1

Acceleration Time

C0802983

LN

20217-6

Deceleration Time

C0803032

LN

20216-8

Deceleration Slope

C0803031

LN

12144-2

Systolic to Diastolic Velocity Ratio

C0552246

LN

59102-4

Flow Radius

C2923437

LN

59130-5

Alias velocity

C2923486

LN

20167-3

Acceleration Slope

C0802982

LN

59127-1

D-E Slope

C2923482

LN

59128-9

E-F Slope

C2923484

LN

59103-2

A-C Interval

C2923439

LN

59104-0

Peak E wave/Peak A wave by US

C2923440

LN

59106-5

Stenosis Peak Gradient

C2923443

LN

59107-3

Stenosis Peak Velocity

C2923444

LN

59079-4

Peak Reversal Velocity during Atrial Contraction

C2923402

LN

59080-2

E-Wave Peak Velocity

C2923404

LN

59081-0

A-Wave Peak Velocity

C2923405

LN

59111-5

E Velocity to Annulus E Velocity Ratio

C2923452

LN

59115-6

Velocity of Flow Propagation

C2923460


Note

  1. In a prior version of this Context Group, the code 11726-7 was specified for Peak Velocity. This has been corrected to be Peak Systolic Velocity. Some applications might continue to send code 11726-7 instead of 20351-3 for Peak Velocity.

  2. In a prior version of this Context Group, the code 20352-1 was specified for Mean Velocity. This has been corrected to be Time Averaged Mean Velocity. Some applications might continue to send code 20352-1 instead of 11692-1 for Time Averaged Peak Velocity.

DICOM PS3.16 2019c - Content Mapping Resource