DICOM PS3.16 2021d - Content Mapping Resource

L Correspondence of Anatomic Region Codes and Body Part Examined Defined Terms

This Annex defines a correspondence between the codes used in context groups for Anatomic Region Sequence (0008,2218) and Body Part Examined (0018,0015), as well as providing a list of the Defined Terms for Body Part Examined (0018,0015), for human use in Table L-1 and for large animal use in Table L-2 and for small animal use in Table L-3. In addition, Table L-5 summarizes whether or not selected anatomic concepts need a laterality modifier (as opposed to being unpaired, or already incorporating laterality as a precoordinated concept).

Note

  1. The tables in this Annex contain the union of a large variety of codes suitable for different applications and modalities, including cross-sectional, projectional and visible light. as such, only a subset will be appropriate for any specific application.

  2. Values for Body Part Examined are limited by the CS VR length restriction to 16 characters in length and hence are somewhat contrived. Some inconsistency in abbreviations may be apparent but this largely reflects historical usage or clinically well recognized usage. No spaces or underscores are used, and singular rather than plural forms are used.

Table L-1. Corresponding Codes and Terms for Human Use

Coding Scheme Designator

Code Value

Code Meaning

Body Part Examined

SNOMED-RT ID (Retired)

FMA Code Value

UMLS Concept UniqueID

SCT

818981001

Abdomen

ABDOMEN

SCT

818982008

Abdomen and Pelvis

ABDOMENPELVIS

SCT

7832008

Abdominal aorta

ABDOMINALAORTA

T-42500

SCT

85856004

Acromioclavicular joint

ACJOINT

T-15420

SCT

23451007

Adrenal gland

ADRENAL

T-B3000

SCT

77012006

Amniotic fluid

AMNIOTICFLUID

T-F1320

SCT

70258002

Ankle joint

ANKLE

T-15750

SCT

128585006

Anomalous pulmonary vein

T-48503

SCT

128553008

Antecubital vein

ANTECUBITALV

T-49215

SCT

194996006

Anterior cardiac vein

ANTCARDIACV

T-48403

SCT

60176003

Anterior cerebral artery

ACA

T-45540

50028

SCT

8012006

Anterior communicating artery

ANTCOMMA

T-45530

SCT

17388009

Anterior spinal artery

ANTSPINALA

T-45730

SCT

68053000

Anterior tibial artery

ANTTIBIALA

T-47700

SCT

53505006

Anus

T-59900

SCT

110612005

Anus, rectum and sigmoid colon

ANUSRECTUMSIGMD

T-59490

SCT

15825003

Aorta

AORTA

T-42000

SCT

57034009

Aortic arch

AORTICARCH

T-42300

SCT

128551005

Aortic fistula

D3-81922

SCT

128564006

Apex of left ventricle

T-32602

SCT

86598002

Apex of Lung

T-280A0

SCT

128565007

Apex of right ventricle

T-32502

SCT

66754008

Appendix

APPENDIX

T-59200

SCT

51114001

Artery

ARTERY

T-41000

SCT

54247002

Ascending aorta

ASCAORTA

T-42100

SCT

9040008

Ascending colon

ASCENDINGCOLON

T-59420

SCT

59652004

Atrium

T-32100

SCT

91470000

Axilla

AXILLA

T-D8104

SCT

67937003

Axillary Artery

AXILLARYA

T-47100

SCT

68705008

Axillary vein

AXILLARYV

T-49110

SCT

72107004

Azygos vein

AZYGOSVEIN

T-48340

SCT

77568009

Back

BACK

T-D2100

SCT

128981007

Baffle

A-00203

SCT

59011009

Basilar artery

BASILARA

T-45800

SCT

28273000

Bile duct

BILEDUCT

T-60610

SCT

34707002

Biliary tract

BILIARYTRACT

T-60600

C0005423

SCT

89837001

Bladder

BLADDER

T-74000

SCT

110837003

Bladder and urethra

BLADDERURETHRA

T-DD123

SCT

91830000

Body conduit

T-D00AB

SCT

72001000

Bone of lower limb

T-12700

SCT

371195002

Bone of upper limb

T-D0821

SCT

128548003

Boyd's perforating vein

T-49424

SCT

17137000

Brachial artery

BRACHIALA

T-47160

SCT

20115005

Brachial vein

BRACHIALV

T-49350

SCT

12738006

Brain

BRAIN

T-A0100

SCT

76752008

Breast

BREAST

T-04000

SCT

34411009

Broad ligament

T-D6500

SCT

955009

Bronchus

BRONCHUS

T-26000

SCT

60819002

Buccal region of face

T-D1206

SCT

46862004

Buttock

BUTTOCK

T-D2600

SCT

80144004

Calcaneus

CALCANEUS

T-12770

SCT

53840002

Calf of leg

CALF

T-D9440

SCT

2334006

Calyx

T-72100

SCT

69105007

Carotid Artery

CAROTID

T-45010

SCT

21479005

Carotid bulb

BULB

T-45170

50094

SCT

57850000

Celiac artery

CELIACA

T-46400

50737

SCT

20699002

Cephalic vein

CEPHALICV

T-49240

SCT

113305005

Cerebellum

CEREBELLUM

T-A6000

SCT

88556005

Cerebral artery

CEREBRALA

T-45510

SCT

372073000

Cerebral hemisphere

CEREBHEMISPHERE

T-A010F

SCT

122494005

Cervical spine

CSPINE

T-11501

SCT

297171002

Cervico-thoracic spine

CTSPINE

T-D00F7

SCT

71252005

Cervix

CERVIX

T-83200

SCT

60819002

Cheek

CHEEK

T-D1206

SCT

43799004

Chest

CHEST

SCT

416775004

Chest, Abdomen and Pelvis

CHESTABDPELVIS

R-FAB56

SCT

416550000

Chest and Abdomen

CHESTABDOMEN

R-FAB55

SCT

80621003

Choroid plexus

CHOROIDPLEXUS

T-A1900

61934

SCT

11279006

Circle of Willis

CIRCLEOFWILLIS

T-45520

SCT

51299004

Clavicle

CLAVICLE

T-12310

SCT

64688005

Coccyx

COCCYX

T-11BF0

SCT

71854001

Colon

COLON

T-59300

SCT

253276007

Common atrium

D4-31005

SCT

79741001

Common bile duct

COMMONBILEDUCT

T-64500

C0009437

SCT

32062004

Common carotid artery

CCA

T-45100

SCT

181347005

Common femoral artery

CFA

T-47402

323778

SCT

397363009

Common femoral vein

CFV

G-035B

323829

SCT

73634005

Common iliac artery

COMILIACA

T-46710

SCT

46027005

Common iliac vein

COMILIACV

T-48920

SCT

45503006

Common ventricle

D4-31120

SCT

128555001

Congenital coronary artery fistula to left atrium

D4-32504

SCT

128556000

Congenital coronary artery fistula to left ventricle

D4-32506

SCT

128557009

Congenital coronary artery fistula to right atrium

D4-32509

SCT

128558004

Congenital coronary artery fistula to right ventricle

D4-32510

SCT

111289009

Pulmonary arteriovenous fistula

D3-40208

SCT

28726007

Cornea

CORNEA

T-AA200

SCT

41801008

Coronary artery

CORONARYARTERY

T-43000

SCT

90219004

Coronary sinus

CORONARYSINUS

T-48410

SCT

128320002

Cranial venous system

T-A0191

SCT

32672002

Descending aorta

DESCAORTA

T-42400

SCT

32622004

Descending colon

DESCENDINGCOLON

T-59460

SCT

128554002

Dodd's perforating vein

T-49429

SCT

38848004

Duodenum

DUODENUM

T-58200

SCT

117590005

Ear

EAR

T-AB001

SCT

16953009

Elbow joint

ELBOW

T-15430

SCT

51114001

Endo-arterial

ENDOARTERIAL

T-41000

SCT

80891009

Endo-cardiac

ENDOCARDIAC

T-32000

SCT

32849002

Endo-esophageal

ENDOESOPHAGEAL

T-56000

SCT

2739003

Endometrium

ENDOMETRIUM

T-83400

SCT

53342003

Endo-nasal

ENDONASAL

T-21300

SCT

18962004

Endo-nasopharyngeal

ENDONASOPHARYNYX

T-23050

SCT

34402009

Endo-rectal

ENDORECTAL

T-59600

SCT

64033007

Endo-renal

ENDORENAL

T-71000

SCT

87953007

Endo-ureteric

ENDOURETERIC

T-73000

SCT

13648007

Endo-urethral

ENDOURETHRAL

T-75000

SCT

76784001

Endo-vaginal

ENDOVAGINAL

T-82000

SCT

59820001

Endo-vascular

ENDOVASCULAR

T-40000

SCT

29092000

Endo-venous

ENDOVENOUS

T-48000

SCT

48367006

Endo-vesical

ENDOVESICAL

T-74250

SCT

38266002

Entire body

WHOLEBODY

T-D0010

SCT

87644002

Epididymis

EPIDIDYMIS

T-95000

18255

SCT

27947004

Epigastric region

EPIGASTRIC

T-D4200

SCT

32849002

Esophagus

ESOPHAGUS

T-56000

SCT

110861005

Esophagus, stomach and duodenum

T-DD163

SCT

84301002

External auditory canal

EAC

T-AB200

SCT

22286001

External carotid artery

ECA

T-45200

SCT

113269004

External iliac artery

EXTILIACA

T-46910

SCT

63507001

External iliac vein

EXTILIACV

T-48930

SCT

71585003

External jugular vein

EXTJUGV

T-48160

13110

C0226543

SCT

66019005

Extremity

EXTREMITY

T-D0300

SCT

81745001

Eye

EYE

T-AA000

SCT

80243003

Eyelid

EYELID

T-AA810

SCT

371398005

Eye region

T-D0801

SCT

89545001

Face

FACE

T-D1200

SCT

23074001

Facial artery

FACIALA

T-45240

SCT

91397008

Facial bones

T-11196

SCT

7657000

Femoral artery

FEMORALA

T-47400

SCT

83419000

Femoral vein

FEMORALV

T-49410

SCT

71341001

Femur

FEMUR

T-12710

Fetal arm

FETALARM

Fetal digit

FETALDIGIT

Fetal heart

FETALHEART

63931

Fetal leg

FETALLEG

Fetal pole

FETALPOLE

SCT

87342007

Fibula

FIBULA

T-12750

SCT

7569003

Finger

FINGER

T-D8800

SCT

58602004

Flank

FLANK

T-D2310

SCT

79361005

Fontanel of skull

FONTANEL

T-15200

SCT

56459004

Foot

FOOT

T-D9700

SCT

14975008

Forearm

FOREARM

T-D8500

SCT

35918002

Fourth ventricle

4THVENTRICLE

T-A1820

SCT

28231008

Gallbladder

GALLBLADDER

T-63000

SCT

110568007

Gastric vein

GASTRICV

T-48820

SCT

128559007

Genicular artery

GENICULARA

T-47490

SCT

300571009

Gestational sac

GESTSAC

F-03FC9

SCT

46862004

Gluteal region

GLUTEAL

T-D2600

SCT

5928000

Great cardiac vein

T-48420

SCT

60734001

Great saphenous vein

GSV

T-49530

21376

SCT

85562004

Hand

HAND

T-D8700

SCT

69536005

Head

HEAD

T-D1100

SCT

774007

Head and Neck

HEADNECK

T-D1000

SCT

80891009

Heart

HEART

T-32000

SCT

76015000

Hepatic artery

HEPATICA

T-46420

SCT

8993003

Hepatic vein

HEPATICV

T-48720

SCT

24136001

Hip joint

HIP

T-15710

SCT

85050009

Humerus

HUMERUS

T-12410

SCT

128560002

Hunterian perforating vein

T-4942A

SCT

11708003

Hypogastric region

HYPOGASTRIC

T-D4240

SCT

81502006

Hypopharynx

HYPOPHARYNX

T-55300

SCT

34516001

Ileum

ILEUM

T-58600

SCT

299716001

Iliac and/or femoral artery

T-41068

SCT

10293006

Iliac artery

ILIACA

T-46700

SCT

244411005

Iliac vein

ILIACV

T-4940E

SCT

22356005

Ilium

ILIUM

T-12340

SCT

195416006

Inferior cardiac vein

T-484A4

SCT

51249003

Inferior left pulmonary vein

T-48540

SCT

33795007

Inferior mesenteric artery

INFMESA

T-46520

SCT

113273001

Inferior right pulmonary vein

T-48520

SCT

64131007

Inferior vena cava

INFVENACAVA

T-48710

SCT

26893007

Inguinal region

INGUINAL

T-D7000

SCT

12691009

Innominate artery

INNOMINATEA

T-46010

SCT

8887007

Innominate vein

INNOMINATEV

T-48620

SCT

361078006

Internal Auditory Canal

IAC

T-AB959

SCT

86117002

Internal carotid artery

ICA

T-45300

SCT

90024005

Internal iliac artery

INTILIACA

T-46740

SCT

12123001

Internal jugular vein

INTJUGULARV

T-48170

SCT

69327007

Internal mammary artery

INTMAMMARYA

T-46200

SCT

818987002

Intra-abdominopelvic

SCT

131183008

Intra-articular

G-A15A

SCT

1101003

Intracranial

INTRACRANIAL

T-D1400

SCT

32849002

Intra-esophageal

T-56000

SCT

816989007

Intra-pelvic

SCT

43799004

Intra-thoracic

SCT

661005

Jaw region

JAW

T-D1213

SCT

21306003

Jejunum

JEJUNUM

T-58400

SCT

39352004

Joint

JOINT

T-15001

SCT

128563000

Juxtaposed atrial appendage

D4-31052

SCT

64033007

Kidney

KIDNEY

T-71000

SCT

72696002

Knee

KNEE

T-D9200

SCT

59749000

Lacrimal artery

LACRIMALA

T-45410

SCT

128979005

Lacrimal artery of right eye

T-45416

SCT

14742008

Large intestine

LARGEINTESTINE

T-59000

SCT

4596009

Larynx

LARYNX

T-24100

SCT

66720007

Lateral Ventricle

LATVENTRICLE

T-A1650

78448

SCT

82471001

Left atrium

LATRIUM

T-32300

SCT

33626005

Left auricular appendage

T-32310

SCT

113270003

Left femoral artery

LFEMORALA

T-47420

SCT

273202007

Left hepatic vein

LHEPATICV

T-48727

14339

SCT

133945003

Left hypochondriac region

LHYPOCHONDRIAC

T-D4211

SCT

85119005

Left inguinal region

LINGUINAL

T-D7020

SCT

68505006

Left lower quadrant of abdomen

LLQ

T-D4140

SCT

133943005

Left lumbar region

LLUMBAR

T-D2340

SCT

70253006

Left portal vein

LPORTALV

T-48814

15415

SCT

50408007

Left pulmonary artery

LPULMONARYA

T-44400

SCT

86367003

Left upper quadrant of abdomen

LUQ

T-D4130

SCT

87878005

Left ventricle

LVENTRICLE

T-32600

SCT

70238003

Left ventricle inflow

T-32640

SCT

13418002

Left ventricle outflow tract

T-32650

SCT

113264009

Lingual artery

LINGUALA

T-45230

SCT

10200004

Liver

LIVER

T-62000

SCT

19100000

Lower inner quadrant of breast

T-04003

SCT

30021000

Lower leg

LEG

T-D9400

SCT

61685007

Lower limb

T-D9000

SCT

33564002

Lower outer quadrant of breast

T-04005

SCT

34635009

Lumbar artery

LUMBARA

T-46960

SCT

52612000

Lumbar region

LUMBAR

T-D2300

SCT

122496007

Lumbar spine

LSPINE

T-11503

SCT

297173004

Lumbo-sacral spine

LSSPINE

T-D00F9

SCT

91747007

Lumen of blood vessel

LUMEN

T-40230

SCT

39607008

Lung

LUNG

T-28000

SCT

91609006

Mandible

JAW

T-11180

SCT

59066005

Mastoid bone

MASTOID

T-11133

SCT

70925003

Maxilla

MAXILLA

T-11170

SCT

72410000

Mediastinum

MEDIASTINUM

T-D3300

SCT

86570000

Mesenteric artery

MESENTRICA

T-46500

SCT

128583004

Mesenteric vein

MESENTRICV

T-4884A

SCT

17232002

Middle cerebral artery

MCA

T-45600

50079

SCT

273099000

Middle hepatic vein

MIDHEPATICV

T-48726

14340

SCT

243977002

Morisons pouch

MORISONSPOUCH

T-D4434

SCT

123851003

Mouth

MOUTH

T-D0662

SCT

102292000

Muscle of lower limb

T-14668

SCT

30608006

Muscle of upper limb

T-13600

SCT

74386004

Nasal bone

T-11149

SCT

360955006

Nasopharynx

NASOPHARYNX

T-2300C

SCT

45048000

Neck

NECK

T-D1600

SCT

416319003

Neck, Chest, Abdomen and Pelvis

NECKCHESTABDPELV

R-FAB54

SCT

416152001

Neck, Chest and Abdomen

NECKCHESTABDOMEN

R-FAB53

SCT

417437006

Neck and Chest

NECKCHEST

R-FAB52

SCT

45206002

Nose

NOSE

T-21000

SCT

31145008

Occipital artery

OCCPITALA

T-45250

SCT

32114007

Occipital vein

OCCIPTALV

T-48214

SCT

113346000

Omental bursa

T-D4450

SCT

27398004

Omentum

T-D4600

SCT

53549008

Ophthalmic artery

OPHTHALMICA

T-45400

SCT

55024004

Optic canal

OPTICCANAL

T-11102

SCT

363654007

Orbital structure

ORBIT

T-D14AE

SCT

15497006

Ovary

OVARY

T-87000

SCT

15776009

Pancreas

PANCREAS

T-65000

SCT

69930009

Pancreatic duct

PANCREATICDUCT

T-65010

SCT

110621006

Pancreatic duct and bile duct systems

PANCBILEDUCT

T-65600

SCT

2095001

Paranasal sinus

T-22000

SCT

91691001

Parasternal

PARASTERNAL

T-D3136

SCT

111002

Parathyroid

PARATHYROID

T-B7000

SCT

45289007

Parotid gland

PAROTID

T-61100

SCT

64234005

Patella

PATELLA

T-12730

SCT

83330001

Patent ductus arteriosus

D4-32012

SCT

816092008

Pelvis

PELVIS

SCT

416631005

Pelvis and lower extremities

R-FAB58

SCT

282044005

Penile artery

PENILEA

T-46807

66318

SCT

18911002

Penis

PENIS

T-91000

SCT

38864007

Perineum

PERINEUM

T-D2700

SCT

8821006

Peroneal artery

PERONEALA

T-47630

DCM

113681

Phantom

SCT

54066008

Pharynx

PHARYNX

T-55000

SCT

312535008

Pharynx and larynx

PHARYNXLARYNX

T-20101

SCT

78067005

Placenta

PLACENTA

T-F1100

SCT

43899006

Popliteal artery

POPLITEALA

T-47500

SCT

32361000

Popliteal fossa

POPLITEALFOSSA

T-D9310

SCT

56849005

Popliteal vein

POPLITEALV

T-49650

44327

SCT

32764006

Portal vein

PORTALV

T-48810

66645

SCT

70382005

Posterior cerebral artery

PCA

T-45900

50583

SCT

43119007

Posterior communicating artery

POSCOMMA

T-45320

SCT

128569001

Posterior medial tributary

T-49535

SCT

13363002

Posterior tibial artery

POSTIBIALA

T-47600

SCT

14944004

Primitive aorta

T-F7001

SCT

91707000

Primitive pulmonary artery

T-F7040

SCT

31677005

Profunda femoris artery

PROFFEMA

T-47440

20741

SCT

23438002

Profunda femoris vein

PROFFEMV

T-49660

51041

SCT

41216001

Prostate

PROSTATE

T-92000

SCT

81040000

Pulmonary artery

PULMONARYA

T-44000

SCT

128584005

Pulmonary artery conduit

D4-33142

SCT

128586007

Pulmonary chamber of cor triatriatum

T-32190

SCT

122972007

Pulmonary vein

PULMONARYV

T-48581

SCT

128566008

Pulmonary vein confluence

D4-33512

SCT

128567004

Pulmonary venous atrium

D4-33514

SCT

45631007

Radial artery

RADIALA

T-47300

SCT

62413002

Radius

RADIUS

T-12420

SCT

110535000

Radius and ulna

RADIUSULNA

T-12403

SCT

53843000

Rectouterine pouch

CULDESAC

T-D6407

SCT

34402009

Rectum

RECTUM

T-59600

SCT

2841007

Renal artery

RENALA

T-46600

SCT

25990002

Renal pelvis

T-72000

SCT

56400007

Renal vein

RENALV

T-48740

SCT

82849001

Retroperitoneum

RETROPERITONEUM

T-D4900

SCT

113197003

Rib

RIB

T-11300

SCT

73829009

Right atrium

RATRIUM

T-32200

SCT

68300000

Right auricular appendage

T-32210

SCT

69833005

Right femoral artery

RFEMORALA

T-47410

SCT

272998002

Right hepatic vein

RHEPATICV

T-48725

14338

SCT

133946002

Right hypochondriac region

RHYPOCHONDRIAC

T-D4212

SCT

37117007

Right inguinal region

RINGUINAL

T-D7010

SCT

48544008

Right lower quadrant of abdomen

RLQ

T-D4120

SCT

133944004

Right lumbar region

RLUMBAR

T-D2342

SCT

73931004

Right portal vein

RPORTALV

T-48813

15414

SCT

78480002

Right pulmonary artery

RPULMONARYA

T-44200

SCT

50519007

Right upper quadrant of abdomen

RUQ

T-D4110

SCT

53085002

Right ventricle

RVENTRICLE

T-32500

SCT

8017000

Right ventricle inflow

T-32540

SCT

44627009

Right ventricle outflow tract

T-32550

SCT

39723000

Sacroiliac joint

SIJOINT

T-15680

SCT

54735007

Sacrum

SSPINE

T-11AD0

SCT

128587003

Saphenofemoral junction

SFJ

T-D930A

SCT

362072009

Saphenous vein

SAPHENOUSV

T-4940B

C0036186

SCT

41695006

Scalp

SCALP

T-D1160

SCT

79601000

Scapula

SCAPULA

T-12280

SCT

18619003

Sclera

SCLERA

T-AA110

SCT

20233005

Scrotum

SCROTUM

T-98000

SCT

42575006

Sella turcica

SELLA

T-D1460

SCT

64739004

Seminal vesicle

SEMVESICLE

T-93000

19386

SCT

58742003

Sesamoid bones of foot

SESAMOID

T-12980

SCT

16982005

Shoulder

SHOULDER

T-D2220

SCT

60184004

Sigmoid colon

SIGMOID

T-59470

SCT

89546000

Skull

SKULL

T-11100

SCT

30315005

Small intestine

SMALLINTESTINE

T-58000

SCT

2748008

Spinal cord

SPINALCORD

T-A7010

SCT

421060004

Spine

SPINE

T-D04FF

SCT

78961009

Spleen

SPLEEN

T-C3000

SCT

22083002

Splenic artery

SPLENICA

T-46460

SCT

35819009

Splenic vein

SPLENICV

T-48890

SCT

7844006

Sternoclavicular joint

SCJOINT

T-15610

SCT

56873002

Sternum

STERNUM

T-11210

SCT

69695003

Stomach

STOMACH

T-57000

SCT

36765005

Subclavian artery

SUBCLAVIANA

T-46100

SCT

9454009

Subclavian vein

SUBCLAVIANV

T-48330

SCT

19695001

Subcostal

SUBCOSTAL

T-D4210

SCT

5713008

Submandibular area

T-D1603

SCT

54019009

Submandibular gland

SUBMANDIBULAR

T-61300

SCT

170887008

Submental

T-D161E

SCT

5076001

Subxiphoid

T-D3213

SCT

181349008

Superficial femoral artery

SFA

T-47403

323777

SCT

397364003

Superficial femoral vein

SFV

G-035A

SCT

15672000

Superficial temporal artery

T-45270

SCT

43863001

Superior left pulmonary vein

LSUPPULMONARYV

T-48530

SCT

42258001

Superior mesenteric artery

SMA

T-46510

SCT

8629005

Superior right pulmonary vein

RSUPPULMONARYV

T-48510

SCT

72021004

Superior thyroid artery

SUPTHYROIDA

T-45210

SCT

48345005

Superior vena cava

SVC

T-48610

SCT

77621008

Supraclavicular region of neck

SUPRACLAVICULAR

T-D1620

SCT

11708003

Suprapubic region

SUPRAPUBIC

T-D4240

SCT

26493002

Suprasternal notch

T-11218

SCT

128589000

Systemic collateral artery to lung

T-44007

SCT

128568009

Systemic venous atrium

D4-33516

SCT

27949001

Tarsal joint

T-15770

SCT

53620006

Temporomandibular joint

TMJ

T-15290

SCT

40689003

Testis

TESTIS

T-94000

SCT

42695009

Thalamus

THALAMUS

T-A4000

62007

SCT

68367000

Thigh

THIGH

T-D9100

SCT

49841001

Third ventricle

3RDVENTRICLE

T-A1740

SCT

113262008

Thoracic aorta

THORACICAORTA

T-42070

SCT

122495006

Thoracic spine

TSPINE

T-11502

SCT

297172009

Thoraco-lumbar spine

TLSPINE

T-D00F8

SCT

43799004

Thorax

THORAX

SCT

76505004

Thumb

THUMB

T-D8810

SCT

9875009

Thymus

THYMUS

T-C8000

SCT

69748006

Thyroid

THYROID

T-B6000

SCT

12611008

Tibia

TIBIA

T-12740

SCT

110536004

Tibia and fibula

TIBIAFIBULA

T-12701

SCT

29707007

Toe

TOE

T-D9800

SCT

21974007

Tongue

TONGUE

T-53000

SCT

44567001

Trachea

TRACHEA

T-25000

SCT

110726009

Trachea and bronchus

TRACHEABRONCHUS

T-DD006

SCT

485005

Transverse colon

TRANSVERSECOLON

T-59440

SCT

61959006

Truncus arteriosus communis

D4-31400

SCT

57850000

Truncus coeliacus

T-46400

SCT

23416004

Ulna

ULNA

T-12430

SCT

44984001

Ulnar artery

ULNARA

T-47200

SCT

50536004

Umbilical artery

UMBILICALA

T-F1810

SCT

90290004

Umbilical region

UMBILICAL

T-D4230

SCT

284639000

Umbilical vein

UMBILICALV

T-48832

SCT

40983000

Upper arm

ARM

T-D8200

SCT

77831004

Upper inner quadrant of breast

T-04002

SCT

53120007

Upper limb

T-D8000

SCT

76365002

Upper outer quadrant of breast

T-04004

SCT

431491007

Upper urinary tract

UPRURINARYTRACT

T-7000B

SCT

87953007

Ureter

URETER

T-73000

SCT

13648007

Urethra

URETHRA

T-75000

SCT

35039007

Uterus

UTERUS

T-83000

SCT

110639002

Uterus and fallopian tubes

T-88920

SCT

76784001

Vagina

VAGINA

T-82000

SCT

118375008

Vascular graft

A-04140

SCT

29092000

Vein

VEIN

T-48000

SCT

34340008

Venous network

T-48003

SCT

21814001

Ventricle

T-32400

SCT

85234005

Vertebral artery

VERTEBRALA

T-45700

SCT

110517009

Vertebral column and cranium

T-11011

SCT

45292006

Vulva

VULVA

T-81000

SCT

74670003

Wrist joint

WRIST

T-15460

SCT

13881006

Zygoma

ZYGOMA

T-11166


Note

In prior versions of this table, different codes were used for some concepts; see PS3.16-2011.

Table L-2. Corresponding Codes and Terms for Large Animals

Coding Scheme Designator

Code Value

Code Meaning

Body Part Examined

SNOMED-RT ID (Retired)

FMA Code Value

UMLS Concept UniqueID

SCT

818981001

Abdomen

ABDOMEN

SCT

42694008

All legs

LEGS

T-D8030

SCT

62555009

Atlantal-axial joint

ATLANTOAXIAL

T-15317

SCT

20292002

Atlanto-occipital joint

ATLANTOOCCIPITAL

T-15311

SCT

89837001

Bladder

BLADDER

T-74000

SCT

82474009

Calcaneal tubercle

T-12771

SCT

8205005

Carpus

CARPUS

T-D8600

SCT

122494005

Cervical spine

CSPINE

T-11501

SCT

297171002

Cervico-thoracic spine

CTSPINE

T-D00F7

SCT

816094009

Chest

CHEST

SCT

416550000

Chest and Abdomen

CHESTABDOMEN

R-FAB55

SCT

18149002

Coccygeal vertrebrae

TAIL

T-11B00

SCT

71854001

Colon

COLON

T-59300

SCT

82680008

Digit

DIGIT

T-D0310

UMLS

C3669027

Distal phalanx

DISTALPHALANX

C3669027

SCT

16953009

Elbow joint

ELBOW

T-15430

SCT

38266002

Entire body

WHOLEBODY

T-D0010

SCT

32849002

Esophagus

ESOPHAGUS

T-56000

SCT

71341001

Femur

FEMUR

T-12710

SCT

13190002

Fetlock of forelimb

FOREFETLOCK

T-D8640

SCT

113351006

Fetlock of hindlimb

HINDFETLOCK

T-D9540

SCT

87342007

Fibula

FIBULA

T-12750

SCT

419176008

Forefoot

FOREFOOT

T-D04F2

SCT

55060009

Frontal sinus

FRONTALSINUS

T-22200

SCT

416804009

Hindfoot

HINDFOOT

T-D9713

SCT

24136001

Hip joint

HIP

T-15710

SCT

85050009

Humerus

HUMERUS

T-12410

SCT

122496007

Lumbar spine

LSPINE

T-11503

SCT

297173004

Lumbo-sacral spine

LSSPINE

T-D00F9

SCT

91609006

Mandible

JAW

T-11180

SCT

88176008

Mandibular dental arch

T-54170

SCT

442274007

Mandibular incisor teeth

T-540EE

SCT

39481002

Maxillary dental arch

T-54160

SCT

442100006

Maxillary incisor teeth

T-540ED

SCT

36455000

Metacarpus

METACARPUS

T-12540

SCT

280711000

Metatarsus

METATARSUS

T-12847

SCT

2095001

Nasal sinus

T-22000

SCT

30518006

Navicular of forefoot

FORENAVICULAR

T-12450

SCT

75772009

Navicular of hindfoot

HINDNAVICULAR

T-12800

SCT

363654007

Orbital structure

ORBIT

T-D14AE

SCT

31329001

Pastern of forefoot

FOREPASTERN

T-D8650

SCT

18525008

Pastern of hindfoot

HINDPASTERN

T-D9550

SCT

64234005

Patella

PATELLA

T-12730

SCT

816092008

Pelvis

PELVIS

SCT

62413002

Radius

RADIUS

T-12420

SCT

110535000

Radius and ulna

RADIUSULNA

T-12403

SCT

54735007

Sacrum

SSPINE

T-11AD0

SCT

16982005

Shoulder

SHOULDER

T-D2220

SCT

89546000

Skull

SKULL

T-11100

SCT

116010006

Stiffle

STIFLE

T-15728

SCT

108371006

Tarsus

TARSUS

T-12761

SCT

122495006

Thoracic spine

TSPINE

T-11502

SCT

297172009

Thoraco-lumbar spine

TLSPINE

T-D00F8

SCT

12611008

Tibia

TIBIA

T-12740

SCT

110536004

Tibia and fibula

TIBIAFIBULA

T-12701

SCT

62834003

Upper gastro-intestinal tract

UGITRACT

T-50110

SCT

23416004

Ulna

ULNA

T-12430

SCT

13648007

Urethra

URETHRA

T-75000

SCT

431938005

Urinary tract

URINARYTRACT

T-7000C

SCT

53036007

Wing

WING

T-D8040


Note

In prior versions of this table, different codes were used for some concepts; see PS3.16-2011.

Table L-3. Corresponding Codes And Terms for Small Animal Use

Coding Scheme Designator

Code Value

Code Meaning

Body Part Examined

SNOMED-RT ID (Retired)

FMA ID

Mouse Anatomy ID

NCIt ID

Uberon ID

UMLS Concept UniqueID

SCT

23451007

Adrenal gland

ADRENAL

T-B3000

9604

0000116

C12666

0002369

C0001625

SCT

70258002

Ankle joint

ANKLE

T-15750

35195

0000463

C32078

0001488

C0003087

SCT

15825003

Aorta

AORTA

T-42000

3734

0000062

C12669

0000947

C0003483

SCT

89837001

Bladder

BLADDER

T-74000

15900

0000380

C12414

0001255

C0005682

SCT

12738006

Brain

BRAIN

T-A0100

50801

0000168

C12439

0000955

C0006104

SCT

76752008

Breast

BREAST

T-04000

57983

0000145

C12367

0001911

C0929301

SCT

955009

Bronchus

BRONCHUS

T-26000

7409

0000436

C12683

0002185

C0006255

SCT

60819002

Buccal region of face

CHEEK

T-D1206

46476

0002475

C13070

0001567

C0007966

SCT

80144004

Calcaneus

CALCANEUS

T-12770

24496

0001348

C32250

0001450

C0006655

SCT

69105007

Carotid Artery

CAROTID

T-45010

0001925

C12687

0005396

C0007272

SCT

113305005

Cerebellum

CEREBELLUM

T-A6000

67944

0000198

C12445

0002037

C0007765

SCT

71252005

Cervix

CERVIX

T-83200

17740

0000392

C12311

0000002

C0007874

SCT

51299004

Clavicle

CLAVICLE

T-12310

13321

0001329

C12695

0001105

C0008913

SCT

64688005

Coccyx

COCCYX

T-11BF0

20229

0001420

C12696

0001095

C0009194

SCT

71854001

Colon

COLON

T-59300

14543

0000335

C12382

0001155

C0009368

SCT

28726007

Cornea

CORNEA

T-AA200

58238

0000266

C12342

0000964

C0010031

SCT

41801008

Coronary artery

CORONARYARTERY

T-43000

49893

0002453

C12843

0001621

C0205042

SCT

82680008

Digit

DIGIT

T-D0310

85518

0000690

C40186

0002544

C0582802

SCT

38848004

Duodenum

DUODENUM

T-58200

7206

0000338

C12263

0002114

C0013303

SCT

16953009

Elbow joint

ELBOW

T-15430

35289

0000451

C32497

0001490

C0013770

SCT

32849002

Esophagus

ESOPHAGUS

T-56000

7131

0000352

C12389

0001043

C0014876

SCT

66019005

Extremity

EXTREMITY

T-D0300

7182

0000007

C12429

0002101

C0015385

SCT

81745001

Eye

EYE

T-AA000

54448

0000261

C12401

0000019

C0015392

SCT

80243003

Eyelid

EYELID

T-AA810

54437

0000268

C12713

0001711

C0015426

SCT

89545001

Face

FACE

T-D1200

24728

0002473

C13071

0001456

C0015450

SCT

71341001

Femur

FEMUR

T-12710

9611

0001359

C12717

0000981

C0015811

SCT

87342007

Fibula

FIBULA

T-12750

24479

0001360

C12718

0001446

C0016068

SCT

7569003

Finger

FINGER

T-D8800

9666

0000041

C32608

0002389

C0016129

SCT

56459004

Foot

FOOT

T-D9700

9664

0000044

C32622

0002387

C0016504

SCT

55060009

Frontal sinus

FRONTALSINUS

T-22200

57417

0001793

C12277

0001760

C0016734

SCT

28231008

Gallbladder

GALLBLADDER

T-63000

7202

0000356

C12377

0002110

C0016976

SCT

85562004

Hand

HAND

T-D8700

9712

0000037

C32712

0002398

C0018563

SCT

69536005

Head

HEAD

T-D1100

7154

0000023

C12419

0000033

C0018670

SCT

774007

Head and Neck

HEADNECK

T-D1000

0000006

C12418

0007811

C0460004

SCT

80891009

Heart

HEART

T-32000

7088

0000072

C12727

0000948

C0018787

SCT

24136001

Hip joint

HIP

T-15710

35178

0000470

C32742

0001486

C0019558

SCT

85050009

Humerus

HUMERUS

T-12410

13303

0001356

C12731

0000976

C0020164

SCT

34516001

Ileum

ILEUM

T-58600

7208

0000339

C12387

0002116

C0020885

SCT

22356005

Ilium

ILIUM

T-12340

16589

0001336

C32765

0001273

C0020889

SCT

661005

Jaw region

JAW

T-D1213

54396

0001905

C48821

0001708

C0022359

SCT

21306003

Jejunum

JEJUNUM

T-58400

7207

0000340

C12388

0002115

C0022378

SCT

64033007

Kidney

KIDNEY

T-71000

7203

0000368

C12415

0002113

C0022646

SCT

10200004

Liver

LIVER

T-62000

7197

0000358

C12392

0002107

C0023884

SCT

30021000

Lower leg

LEG