DICOM PS3.16 2020a - Content Mapping Resource

G English Code Meanings of Selected Codes (Normative)

Table G-1. English Code Meanings of Selected Codes

Coding Scheme Designator

Code Value

Code Meaning

UCUM

1

unary

no units

UCUM

{ratio}

ratio

SCT

31811003

Carbon dioxide

Carbon dioxide gas

SCT

419442005

Ethanol

Ethyl alcohol

SCT

1182007

Hypotensive agent

Antihypertensive agent

Antihypertensive drug

SCT

303960004

Thrombolytic agent

Fibrinolytic agent

SCT

764170006

Fibrinolysin

Plasmin

SCT

7140000

Contrast agent

Radiographic contrast agent

SCT

33271006

Iodohippurate I^131^ sodium

Iodine^131^ hippuran

SCT

35884005

Iodine^131^ polyvinylpyrrolidone

Iodine^131^ PVP

SCT

87410002

Technetium Tc^99^ N-substituted iminodiacetate

Tc^99^ labeled HIDA

SCT

111289009

Congenital pulmonary arteriovenous fistula

Congenital coronary artery fistula to pulmonary artery

SCT

128584005

Pulmonary artery conduit

Congenital pulmonary artery conduit

SCT

128566008

Pulmonary vein confluence

Congenital pulmonary vein confluence

SCT

128567004

Pulmonary venous atrium

Congenital pulmonary venous atrium

SCT

128568009

Systemic venous atrium

Congenital systemic venous atrium

SCT

399348003

Antero-posterior

AP

SCT

272479007

Postero-anterior

PA

SCT

399004004

Oblique axial

Oblique caudo-cranial

Oblique cranio-caudal

Oblique transaxial

Off-axial

Off-axial projection

SCT

399260004

Medial-lateral

Medio-lateral

SCT

399099002

Lateral-medial

Latero-medial

SCT

399198007

Right lateral projection

Left to right beam projection

SCT

399173006

Left lateral projection

Right to left beam projection

SCT

399162004

caudad

caudal projection

cranio-caudal projection

SCT

399196006

cephalad

cranial projection

caudo-cranial projection

from below

SCT

272466003

transforamenal

optic foramen projection

SCT

24028007

Right

Right lateral

SCT

7771000

Left

Left lateral

SCT

51440002

Bilateral

Right and left

SCT

66459002

Unilateral

One-sided

SCT

255549009

Anterior

Ventral

SCT

255551008

Posterior

Dorsal

SCT

66787007

Cephalic

Cephalad

Rostral

Cranial

SCT

3583002

Caudal

Caudad

SCT

255561001

Medial

SCT

261129000

Mediolateral

Midline

SCT

261074009

External

Outer

SCT

260521003

Internal

Inner

SCT

261089000

Inferior

Lower

SCT

264217000

Superior

Upper

SCT

81654009

Coronal

Frontal

SCT

795002

Deep

Profundis

SCT

399067008

Sagittal Projection

Lateral Projection

SCT

11723008

Contact with

Direct contact

SCT

32381004

Hilar

Hilus

SCT

57183005

Edge

Along edge

SCT

372464004

Intracutaneous route

Intradermal route

SCT

26643006

Oral route

Peroral route

SCT

16857009

Vaginal route

Per vagina

SCT

45211000

Catheterization

Insertion of catheter

SCT

6832004

Atherectomy

Removal of atherosclerotic plaque from artery

SCT

74670003

Wrist joint

Joint of Wrist

SCT

80891009

Endo-cardiac

Intra-cardiac

SCT

51114001

Endo-arterial

Intra-arterial

SCT

12691009

Innominate artery

Brachiocephalic artery

Brachiocephalic trunk

SCT

12123001

Internal jugular vein

Vena jugularis interna

SCT

8887007

Innominate vein

Brachiocephalic vein

SCT

32764006

Portal vein

Vena portae

SCT

113346000

Omental bursa

Lesser peritoneal sac

LN

33068-8

Thoracic Area

FTA

LN

33070-4

Inner Orbital Diameter

IOD

LN

11727-5

Estimated Weight

EFW

LN

11948-7

Fetal Heart Rate

HR

LN

11778-8

Estimated Date of Delivery

EDD

LN

11955-2

Last Menstrual Period

LMP

LN

11979-2

Abdominal Circumference

AC

LN

11818-2

Anterior-Posterior Abdominal Diameter

APAD

LN

11820-8

Biparietal Diameter

BPD

LN

11824-0

BPD area corrected

BPDa

LN

11963-6

Femur Length

FL

LN

11984-2

Head Circumference

HC

LN

11851-3

Occipital-Frontal Diameter

OFD

LN

11988-3

Thoracic Circumference

TC

LN

11862-0

Transverse Abdominal Diameter

TAD

LN

11863-8

Transverse Cerebellar Diameter

TCD

TDC

LN

11864-6

Transverse Thoracic Diameter

TTD

LN

11629-3

Outer Orbital Diameter

OOD

LN

11726-7

Peak Velocity

Peak Systolic Velocity

Mid

SCT

21479005

Carotid Bulb

Carotid Sinus

LN

8277-6

Body Surface Area

BSA

LN

29462-9

Pulmonary-to-Systemic Shunt Flow Ratio

Qp/Qs

SCT

263677008

Antegrade Direction

Antegrade Flow

SCT

312004007

Retrograde Direction

Regurgitant Flow

LN

11957-8

Crown Rump Length

CRL

SCT

119853006

Breast implantation

Implant procedure

SCT

27315000

Removal of breast implant

Explantation

SCT

247472004

Weal

Hives

SCT

271989003

Disorder of breast implant

Breast implant problem

SCT

89164003

Breast lump

Lump or thickening

SCT

87386002

Peau d'orange surface of breast

Peau d'orange

SCT

290113009

Bloody nipple discharge

Bloody discharge

SCT

110265006

Hemorrhage postprocedure

Abnormal bleeding

SCT

408678008

Healthcare associated infection

Infection

SCT

169254007

Ultrasound scan normal

Normal; the finding is not seen sonographically

SCT

280416009

Indeterminate result

Inconclusive

SCT

384668003

Nottingham Combined Grade cannot be determined

GX - grade cannot be assessed

SCT

309587003

Calcification of breast

Calcifications

SCT

290069002

Discoloration of skin of breast

Redness of skin

SCT

290119008

Nipple problem

Nipple abnormality

SCT

279047007

Persistent pain following procedure

Unusual pain

SCT

398665005

Vasovagal syncope

SCT

369790002

Nottingham Combined Grade I: 3-5 points

G1 - Low combined histologic grade (favorable)

SCT

369791003

Nottingham Combined Grade II: 6-7 points

G2 - Intermediate combined histo grade (moderately favorable)

SCT

369792005

Nottingham Combined Grade III: 8-9 points

G3 - High combined histologic grade (unfavorable)

SCT

63130001

Surgical scar

Post-surgical scar

SCT

277591006

Computed tomography guided biopsy

CT guided

SCT

277592004

Magnetic resonance imaging guided biopsy

MRI guided

SCT

277667006

Ultrasound guided biopsy

Ultrasound guided

SCT

237380007

Pre-biopsy localization of breast lesion

Localization for surgical biopsy

SCT

287572003

Diagnostic aspiration of breast cyst

Cyst aspiration

SCT

387736007

Fine needle aspiration of breast

FNA - Fine needle aspiration

SCT

44578009

Core needle biopsy of breast

Core biopsy

SCT

274331003

Breast - surgical biopsy

Surgical biopsy

SCT

46662001

Examination of breast

Clinical breast exam

SCT

64318009

Diagnostic radiography, stereotactic localization

Stereotactic

SCT

80865008

Specimen radiography of breast

Specimen imaging

SCT

66377006

Radionuclide localization of tumor, limited area

Scintimammography

SCT

164150006

O/E - axillary lymphadenopathy

Large axillary lymph nodes

SCT

268951004

O/E - Breast lump palpated

Palpable abnormality

SCT

307153007

Before procedure

Pre-

SCT

258270003

High risk tumor

High risk

SCT

303110006

After procedure

Follow-up

SCT

408714007

vessel lumen cross sectional area reduction

lumen area stenosis

SCT

408715008

vessel lumen diameter reduction

lumen diameter stenosis

SCT

61593002

Ultrasonic guidance procedure

Ultrasound guided

SCT

129716005

Almost entirely fat

Almost entirely fat (< = 10% fibroglandular)

SCT

129717001

Scattered fibroglandular densities

Scattered fibroglandular tissue (11% - 50% fibroglandular)

SCT

129718006

Heterogeneously dense

Heterogeneously dense (51% - 75% fibroglandular)

SCT

129719003

Extremely dense

Extremely dense (greater than 75% fibroglandular)

SCT

129763007

Heterogeneous calcification

Coarse heterogeneous calcification

SCT

129789007

Focal asymmetric breast tissue

Focal asymmetry

SCT

129790003

Asymmetric breast tissue

Global asymmetry

SCT

129794007

Tubular density

Asymmetric tubular structure/solitary dilated duct

SCT

86616005

Intraductal carcinoma, non-infiltrating

DCIS

SCT

386053000

Evaluation procedure

Clinical evaluation

SCT

169167001

Radioisotope scan of lymphatic system

Lymphoscintigraphy

SCT

102314001

Embolization coil

Gianturco coil

SCT

12691009

Brachiocephalic artery

Brachiocephalic trunk

Innominate artery

DCM

111046

Percent Fibroglandular Tissue

Percent Glandular Tissue

LN

20280-4

Pressure Half Time

Pressure Half Time by US.calculated

LN

59089-3

Thickness

ROI Thickness by US

LN

59090-1

Internal Dimension

ROI Internal Dimension by US

LN

20247-3

Peak Gradient [Pressure]

Peak Gradient [Pressure] by US.calculated

LN

20256-4

Mean Gradient [Pressure]

Mean Gradient [Pressure] by Doppler

SCT

396655006

Left ventricle mid inferolateral segment

Left Ventricle Posterior Wall

SCT

444371003

Ventricular Ejection

S-wave

s-prime

SCT

444392003

Diastolic Rapid Inflow

E-wave

e-prime

SCT

59972007

Atrial Systole

A-wave

a-prime

SCT

448169003

Felis catus

Domestic cat

SCT

35354009

Equus caballus

Domestic horse

SCT

125099002

Ovis aries

Domestic sheep

SCT

125097000

Capra hircus

Domestic goat

SCT

448771007

Canis lupus familiaris

Domestic dog

SCT

34618005

Bos taurus

Domestic cow

SCT

447612001

Mus musculus

House mouse

ITIS_TSN

180278

Peromyscus leucopus

American white-footed mouse

ITIS_TSN

180276

Peromyscus maniculatus

Deer mouse

SCT

371565004

Rattus norvegicus

Common rat

ITIS_TSN

180346

Sigmodon genus

Cotton rat

SCT

125076001

Cavia porcellus

Domestic guinea pig

SCT

449310008

Mustela putorius furo

Ferret

SCT

36571002

Oryctolagus cuniculus

European rabbit

SCT

406733009

Callithrix jacchus

Common marmoset


DICOM PS3.16 2020a - Content Mapping Resource