DICOM PS3.6 2021d - Data Dictionary

A Registry of DICOM Unique Identifiers (UIDs) (Normative)

Table A-1 lists the UID values that are registered and used throughout the Parts of the DICOM Standard. This central registry ensures that when additional UIDs are assigned, non-duplicate values are assigned. For retired UIDs, the edition of the Standard in parentheses is the edition in which the item last appeared before it was retired.

Table A-1. UID Values

UID Value

UID Name

UID ​Keyword

UID Type

Part

1.2.840.10008.1.​1

Verification SOP Class

Verification

SOP Class

PS3.4

1.2.840.10008.1.​2

Implicit VR Little Endian: Default Transfer Syntax for DICOM

Implicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​1

Explicit VR Little Endian

Explicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​1.98

Encapsulated Uncompressed Explicit VR Little Endian

Encapsulated​Uncompressed​Explicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​1.​99

Deflated Explicit VR Little Endian

Deflated​Explicit​VR​Little​Endian

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​2

Explicit VR Big Endian (Retired)

Explicit​VR​Big​Endian

Transfer Syntax

PS3.5 (2011)

1.2.840.10008.1.2.​4.​50

JPEG Baseline (Process 1): Default Transfer Syntax for Lossy JPEG 8 Bit Image Compression

JPEG​Baseline​8​Bit

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​51

JPEG Extended (Process 2 & 4): Default Transfer Syntax for Lossy JPEG 12 Bit Image Compression (Process 4 only)

JPEG​Extended​12​Bit

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​52

JPEG Extended (Process 3 & 5) (Retired)

JPEG​Extended35

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​53

JPEG Spectral Selection, Non-Hierarchical (Process 6 & 8) (Retired)

JPEG​Spectral​Selection​Non​Hierarchical68

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​54

JPEG Spectral Selection, Non-Hierarchical (Process 7 & 9) (Retired)

JPEG​Spectral​Selection​Non​Hierarchical79

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​55

JPEG Full Progression, Non-Hierarchical (Process 10 & 12) (Retired)

JPEG​Full​Progression​Non​Hierarchical1012

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​56

JPEG Full Progression, Non-Hierarchical (Process 11 & 13) (Retired)

JPEG​Full​Progression​Non​Hierarchical1113

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​57

JPEG Lossless, Non-Hierarchical (Process 14)

JPEG​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​58

JPEG Lossless, Non-Hierarchical (Process 15) (Retired)

JPEG​Lossless​Non​Hierarchical​15

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​59

JPEG Extended, Hierarchical (Process 16 & 18) (Retired)

JPEG​Extended​Hierarchical​1618

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​60

JPEG Extended, Hierarchical (Process 17 & 19) (Retired)

JPEG​Extended​Hierarchical​1719

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​61

JPEG Spectral Selection, Hierarchical (Process 20 & 22) (Retired)

JPEG​Spectral​Selection​Hierarchical2022

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​62

JPEG Spectral Selection, Hierarchical (Process 21 & 23) (Retired)

JPEG​Spectral​Selection​Hierarchical2123

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​63

JPEG Full Progression, Hierarchical (Process 24 & 26) (Retired)

JPEG​Full​Progression​Hierarchical2426

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​64

JPEG Full Progression, Hierarchical (Process 25 & 27) (Retired)

JPEG​Full​Progression​Hierarchical2527

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​65

JPEG Lossless, Hierarchical (Process 28) (Retired)

JPEG​Lossless​Hierarchical​28

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​66

JPEG Lossless, Hierarchical (Process 29) (Retired)

JPEG​Lossless​Hierarchical​29

Transfer Syntax

PS3.5 (2001)

1.2.840.10008.1.2.​4.​70

JPEG Lossless, Non-Hierarchical, First-Order Prediction (Process 14 [Selection Value 1]): Default Transfer Syntax for Lossless JPEG Image Compression

JPEG​Lossless​SV1

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​80

JPEG-LS Lossless Image Compression

JPEG​LS​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​81

JPEG-LS Lossy (Near-Lossless) Image Compression

JPEG​LS​Near​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​90

JPEG 2000 Image Compression (Lossless Only)

JPEG​2000Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​91

JPEG 2000 Image Compression

JPEG​2000

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​92

JPEG 2000 Part 2 Multi-component Image Compression (Lossless Only)

JPEG​2000MCLossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​93

JPEG 2000 Part 2 Multi-component Image Compression

JPEG​2000MC

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​94

JPIP Referenced

JPIP​Referenced

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​95

JPIP Referenced Deflate

JPIP​Referenced​Deflate

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​100

MPEG2 Main Profile / Main Level

MPEG2​MPML

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​101

MPEG2 Main Profile / High Level

MPEG2​MPHL

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​102

MPEG-4 AVC/H.264 High Profile / Level 4.1

MPEG4​HP41

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​103

MPEG-4 AVC/H.264 BD-compatible High Profile / Level 4.1

MPEG4​HP41BD

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​104

MPEG-4 AVC/H.264 High Profile / Level 4.2 For 2D Video

MPEG4​HP422D

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​105

MPEG-4 AVC/H.264 High Profile / Level 4.2 For 3D Video

MPEG4​HP423D

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.​106

MPEG-4 AVC/H.264 Stereo High Profile / Level 4.2

MPEG4​HP42STEREO

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.107

HEVC/H.265 Main Profile / Level 5.1

HEVC​MP51

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​4.108

HEVC/H.265 Main 10 Profile / Level 5.1

HEVC​M10P51

Transfer Syntax

PS3.5

1.2.840.10008.1.​2.​5

RLE Lossless

RLE​Lossless

Transfer Syntax

PS3.5

1.2.840.10008.1.2.​6.​1

RFC 2557 MIME encapsulation (Retired)

RFC​2557​MIME​Encapsulation

Transfer Syntax

PS3.10 (2018b)

1.2.840.10008.1.2.​6.​2

XML Encoding (Retired)

XML​Encoding

Transfer Syntax

PS3.10 (2018b)

1.2.840.10008.1.2.7.1

SMPTE ST 2110-20 Uncompressed Progressive Active Video

SMPTE​ST​211020​Uncompressed​Progressive​Active​Video

Transfer Syntax

PS3.5

1.2.840.10008.1.2.7.2

SMPTE ST 2110-20 Uncompressed Interlaced Active Video

SMPTE​ST​211020​Uncompressed​Interlaced​Active​Video

Transfer Syntax

PS3.5

1.2.840.10008.1.2.7.3

SMPTE ST 2110-30 PCM Digital Audio

SMPTE​ST​211030​PCMDigital​Audio

Transfer Syntax

PS3.5

1.2.840.10008.1.​3.​10

Media Storage Directory Storage

Media​Storage​Directory​Storage

SOP Class

PS3.4

1.2.840.10008.1.​5.​1

Hot Iron Color Palette SOP Instance

Hot​Iron​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​2

PET Color Palette SOP Instance

PET​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​3

Hot Metal Blue Color Palette SOP Instance

Hot​Metal​Blue​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​4

PET 20 Step Color Palette SOP Instance

PET​20​Step​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​5

Spring Color Palette SOP Instance

Spring​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​6

Summer Color Palette SOP Instance

Summer​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​7

Fall Color Palette SOP Instance

Fall​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​5.​8

Winter Color Palette SOP Instance

Winter​Palette

Well-known SOP Instance

PS3.6

1.2.840.10008.1.​9

Basic Study Content Notification SOP Class (Retired)

Basic​Study​Content​Notification

SOP Class

PS3.4 (2004)

1.2.840.10008.1.​20

Papyrus 3 Implicit VR Little Endian (Retired)

Papyrus​3​Implicit​VR​Little​Endian

Transfer Syntax

(2015c)

1.2.840.10008.1.​20.​1

Storage Commitment Push Model SOP Class

Storage​Commitment​Push​Model

SOP Class

PS3.4

1.2.840.10008.1.20.​1.​1

Storage Commitment Push Model SOP Instance

Storage​Commitment​Push​Model​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​20.​2

Storage Commitment Pull Model SOP Class (Retired)

Storage​Commitment​Pull​Model​

SOP Class

PS3.4 (2001)

1.2.840.10008.1.20.​2.​1

Storage Commitment Pull Model SOP Instance (Retired)

Storage​Commitment​Pull​Model​Instance

Well-known SOP Instance

PS3.4 (2001)

1.2.840.10008.1.​40

Procedural Event Logging SOP Class

Procedural​Event​Logging

SOP Class

PS3.4

1.2.840.10008.1.​40.​1

Procedural Event Logging SOP Instance

Procedural​Event​Logging​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.1.​42

Substance Administration Logging SOP Class

Substance​Administration​Logging

SOP Class

PS3.4

1.2.840.10008.1.​42.​1

Substance Administration Logging SOP Instance

Substance​Administration​Logging​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.2.​6.​1

DICOM UID Registry

DCMUID

DICOM UIDs as a Coding Scheme

PS3.6

1.2.840.10008.2.​16.​4

DICOM Controlled Terminology

DCM

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​5

Adult Mouse Anatomy Ontology

MA

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​6

Uberon Ontology

UBERON

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​7

Integrated Taxonomic Information System (ITIS) Taxonomic Serial Number (TSN)

ITIS_TSN

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​8

Mouse Genome Initiative (MGI)

MGI

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​9

Pub​Chem Compound CID

PUBCHEM_CID

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​10

Dublin Core

DC

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​11

New York University Melanoma Clinical Cooperative Group

NYUMCCG

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​12

Mayo Clinic Non-radiological Images Specific Body Structure Anatomical Surface Region Guide

MAYONRISBSASRG

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​13

Image Biomarker Standardisation Initiative

IBSI

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​14

Radiomics Ontology

RO

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​15

RadElement

RADELEMENT

Coding Scheme

PS3.16

1.2.840.10008.2.​16.​16

ICD-11

I11

Coding Scheme

PS3.16

1.2.840.10008.3.1.​1.​1

DICOM Application Context Name

DICOM​Application​Context

Application Context Name

PS3.7

1.2.840.10008.3.1.2.​1.​1

Detached Patient Management SOP Class (Retired)

Detached​Patient​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​1.​4

Detached Patient Management Meta SOP Class (Retired)

Detached​Patient​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​2.​1

Detached Visit Management SOP Class (Retired)

Detached​Visit​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​3.​1

Detached Study Management SOP Class (Retired)

Detached​Study​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​3.​2

Study Component Management SOP Class (Retired)

Study​Component​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​3.​3

Modality Performed Procedure Step SOP Class

Modality​Performed​Procedure​Step

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​4

Modality Performed Procedure Step Retrieve SOP Class

Modality​Performed​Procedure​Step​Retrieve

SOP Class

PS3.4

1.2.840.10008.3.1.2.​3.​5

Modality Performed Procedure Step Notification SOP Class

Modality​Performed​Procedure​Step​Notification

SOP Class

PS3.4

1.2.840.10008.3.1.2.​5.​1

Detached Results Management SOP Class (Retired)

Detached​Results​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​5.​4

Detached Results Management Meta SOP Class (Retired)

Detached​Results​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​5.​5

Detached Study Management Meta SOP Class (Retired)

Detached​Study​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.3.1.2.​6.​1

Detached Interpretation Management SOP Class (Retired)

Detached​Interpretation​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.4.​2

Storage Service Class

Storage

Service Class

PS3.4

1.2.840.10008.5.1.​1.​1

Basic Film Session SOP Class

Basic​Film​Session

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​2

Basic Film Box SOP Class

Basic​Film​Box

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​4

Basic Grayscale Image Box SOP Class

Basic​Grayscale​Image​Box

SOP Class

PS3.4

1.2.840.10008.5.1.1.​4.​1

Basic Color Image Box SOP Class

Basic​Color​Image​Box

SOP Class

PS3.4

1.2.840.10008.5.1.1.​4.​2

Referenced Image Box SOP Class (Retired)

Referenced​Image​Box

SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.​1.​9

Basic Grayscale Print Management Meta SOP Class

Basic​Grayscale​Print​Management​Meta

Meta SOP Class

PS3.4

1.2.840.10008.5.1.1.​9.​1

Referenced Grayscale Print Management Meta SOP Class (Retired)

Referenced​Grayscale​Print​Management​Meta

Meta SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.​1.​14

Print Job SOP Class

Print​Job

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​15

Basic Annotation Box SOP Class

Basic​Annotation​Box

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​16

Printer SOP Class

Printer

SOP Class

PS3.4

1.2.840.10008.5.1.1.​16.​376

Printer Configuration Retrieval SOP Class

Printer​Configuration​Retrieval

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​17

Printer SOP Instance

Printer​Instance

Well-known Printer SOP Instance

PS3.4

1.2.840.10008.5.1.1.​17.​376

Printer Configuration Retrieval SOP Instance

Printer​Configuration​Retrieval​Instance

Well-known Printer SOP Instance

PS3.4

1.2.840.10008.5.1.​1.​18

Basic Color Print Management Meta SOP Class

Basic​Color​Print​Management​Meta

Meta SOP Class

PS3.4

1.2.840.10008.5.1.1.​18.​1

Referenced Color Print Management Meta SOP Class (Retired)

Referenced​Color​Print​Management​Meta

Meta SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.​1.​22

VOI LUT Box SOP Class

VOI​LUT​Box

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​23

Presentation LUT SOP Class

Presentation​LUT

SOP Class

PS3.4

1.2.840.10008.5.1.​1.​24

Image Overlay Box SOP Class (Retired)

Image​Overlay​Box

SOP Class

PS3.4 (1998)

1.2.840.10008.5.1.1.​24.​1

Basic Print Image Overlay Box SOP Class (Retired)

Basic​Print​Image​Overlay​Box

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​25

Print Queue SOP Instance (Retired)

Print​Queue

Well-known Print Queue SOP Instance

PS3.4 (2004)

1.2.840.10008.5.1.​1.​26

Print Queue Management SOP Class (Retired)

Print​Queue​Management

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​27

Stored Print Storage SOP Class (Retired)

Stored​Print​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​29

Hardcopy Grayscale Image Storage SOP Class (Retired)

Hardcopy​Grayscale​Image​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​30

Hardcopy Color Image Storage SOP Class (Retired)

Hardcopy​Color​Image​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​31

Pull Print Request SOP Class (Retired)

Pull​Print​Request

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​32

Pull Stored Print Management Meta SOP Class (Retired)

Pull​Stored​Print​Management​Meta

Meta SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.​1.​33

Media Creation Management SOP Class UID

Media​Creation​Management

SOP Class

PS3.4

1.2.840.10008.5.1.1.40

Display System SOP Class

Display​System

SOP Class

PS3.4

1.2.840.10008.5.1.1.40.1

Display System SOP Instance

Display​System​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.1.​1.​1

Computed Radiography Image Storage

Computed​Radiography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​1

Digital X-Ray Image Storage - For Presentation

Digital​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​1.​1

Digital X-Ray Image Storage - For Processing

Digital​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​2

Digital Mammography X-Ray Image Storage - For Presentation

Digital​Mammography​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​2.​1

Digital Mammography X-Ray Image Storage - For Processing

Digital​Mammography​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​1.​3

Digital Intra-Oral X-Ray Image Storage - For Presentation

Digital​Intra​Oral​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.1.​3.​1

Digital Intra-Oral X-Ray Image Storage - For Processing

Digital​Intra​Oral​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​2

CT Image Storage

CT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​2.​1

Enhanced CT Image Storage

Enhanced​CT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​2.​2

Legacy Converted Enhanced CT Image Storage

Legacy​Converted​Enhanced​CT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​3

Ultrasound Multi-frame Image Storage (Retired)

Ultrasound​Multi​Frame​Image​Storage​Retired

SOP Class

PS3.4 (1993)

1.2.840.10008.​5.​1.​4.​1.​1.​3.​1

Ultrasound Multi-frame Image Storage

Ultrasound​Multi​Frame​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​4

MR Image Storage

MR​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​1

Enhanced MR Image Storage

Enhanced​MR​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​2

MR Spectroscopy Storage

MR​Spectroscopy​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​3

Enhanced MR Color Image Storage

Enhanced​MR​Color​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​4.​4

Legacy Converted Enhanced MR Image Storage

Legacy​Converted​Enhanced​MR​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​5

Nuclear Medicine Image Storage (Retired)

Nuclear​Medicine​Image​Storage​Retired

SOP Class

PS3.4 (1993)

1.2.840.10008.5.1.4.1.​1.​6

Ultrasound Image Storage (Retired)

Ultrasound​Image​Storage​Retired

SOP Class

PS3.4 (1993)

1.2.840.10008.​5.​1.​4.​1.​1.​6.​1

Ultrasound Image Storage

Ultrasound​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​6.​2

Enhanced US Volume Storage

Enhanced​US​Volume​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​7

Secondary Capture Image Storage

Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​1

Multi-frame Single Bit Secondary Capture Image Storage

Multi​Frame​Single​Bit​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​2

Multi-frame Grayscale Byte Secondary Capture Image Storage

Multi​Frame​Grayscale​Byte​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​3

Multi-frame Grayscale Word Secondary Capture Image Storage

Multi​Frame​Grayscale​Word​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​7.​4

Multi-frame True Color Secondary Capture Image Storage

Multi​Frame​True​Color​Secondary​Capture​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​8

Standalone Overlay Storage (Retired)

Standalone​Overlay​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.​1.​9

Standalone Curve Storage (Retired)

Standalone​Curve​​​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.​5.​1.​4.​1.​1.​9.​1

Waveform Storage - Trial (Retired)

Waveform​​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​1

12-lead ECG Waveform Storage

Twelve​Lead​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​2

General ECG Waveform Storage

General​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​1.​3

Ambulatory ECG Waveform Storage

Ambulatory​ECG​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​2.​1

Hemodynamic Waveform Storage

Hemodynamic​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​3.​1

Cardiac Electrophysiology Waveform Storage

Cardiac​Electrophysiology​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​4.​1

Basic Voice Audio Waveform Storage

Basic​Voice​Audio​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​4.​2

General Audio Waveform Storage

General​Audio​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​5.​1

Arterial Pulse Waveform Storage

Arterial​Pulse​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​6.​1

Respiratory Waveform Storage

Respiratory​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​6.​2

Multi-channel Respiratory Waveform Storage

Multi​channel​Respiratory​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​1

Routine Scalp Electroencephalogram Waveform Storage

Routine​Scalp​Electroencephalogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​2

Electromyogram Waveform Storage

Electromyogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​3

Electrooculogram Waveform Storage

Electrooculogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​7.​4

Sleep Electroencephalogram Waveform Storage

Sleep​Electroencephalogram​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.9.​8.​1

Body Position Waveform Storage

Body​Position​Waveform​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​10

Standalone Modality LUT Storage (Retired)

Standalone​Modality​LUT​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.​1.​11

Standalone VOI LUT Storage (Retired)

Standalone​VOI​LUT​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.​5.​1.​4.​1.​1.​11.​1

Grayscale Softcopy Presentation State Storage

Grayscale​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​2

Color Softcopy Presentation State Storage

Color​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​3

Pseudo-Color Softcopy Presentation State Storage

Pseudo​Color​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​4

Blending Softcopy Presentation State Storage

Blending​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​5

XA/XRF Grayscale Softcopy Presentation State Storage

XA​XRF​Grayscale​Softcopy​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​6

Grayscale Planar MPR Volumetric Presentation State Storage

Grayscale​Planar​MPR​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​7

Compositing Planar MPR Volumetric Presentation State Storage

Compositing​Planar​MPR​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​8

Advanced Blending Presentation State Storage

Advanced​Blending​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​9

Volume Rendering Volumetric Presentation State Storage

Volume​Rendering​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​10

Segmented Volume Rendering Volumetric Presentation State Storage

Segmented​Volume​Rendering​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​11.​11

Multiple Volume Rendering Volumetric Presentation State Storage

Multiple​Volume​Rendering​Volumetric​Presentation​State​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​1

X-Ray Angiographic Image Storage

X​Ray​Angiographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.12.​1.​1

Enhanced XA Image Storage

Enhanced​XA​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​2

X-Ray Radiofluoroscopic Image Storage

X​Ray​Radiofluoroscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.12.​2.​1

Enhanced XRF Image Storage

Enhanced​XRF​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​12.​3

X-Ray Angiographic Bi-Plane Image Storage (Retired)

XRay​Angiographic​Bi​Plane​Image​Storage

SOP Class

PS3.4 (1998)

1.2.840.10008.​5.​1.​4.​1.​1.​12.​77

(Retired)

SOP Class

(2015c)

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​1

X-Ray 3D Angiographic Image Storage

X​Ray​3D​Angiographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​2

X-Ray 3D Craniofacial Image Storage

X​Ray​3D​Craniofacial​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.13.​1.​3

Breast Tomosynthesis Image Storage

Breast​Tomosynthesis​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.1.4.1.1.13.1.4

Breast Projection X-Ray Image Storage - For Presentation

Breast​Projection​X​Ray​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.1.4.1.1.13.1.5

Breast Projection X-Ray Image Storage - For Processing

Breast​Projection​X​Ray​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​14.​1

Intravascular Optical Coherence Tomography Image Storage - For Presentation

Intravascular​Optical​Coherence​Tomography​Image​​StorageFor​Presentation

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​14.​2

Intravascular Optical Coherence Tomography Image Storage - For Processing

Intravascular​Optical​Coherence​Tomography​Image​​StorageFor​Processing

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​20

Nuclear Medicine Image Storage

Nuclear​Medicine​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​30

Parametric Map Storage

Parametric​Map​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​40

(Retired)

SOP Class

(2015c)

1.2.840.10008.5.1.4.1.​1.​66

Raw Data Storage

Raw​Data​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​1

Spatial Registration Storage

Spatial​Registration​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​2

Spatial Fiducials Storage

Spatial​Fiducials​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​3

Deformable Spatial Registration Storage

Deformable​Spatial​Registration​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​4

Segmentation Storage

Segmentation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​5

Surface Segmentation Storage

Surface​Segmentation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​66.​6

Tractography Results Storage

Tractography​Results​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​67

Real World Value Mapping Storage

Real​World​Value​Mapping​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​68.​1

Surface Scan Mesh Storage

Surface​Scan​Mesh​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​68.​2

Surface Scan Point Cloud Storage

Surface​Scan​Point​Cloud​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​77.​1

VL Image Storage - Trial (Retired)

VL​Image​Storage​Trial

SOP Class

PS3.4 (1998)

1.2.840.10008.​5.​1.​4.​1.​1.​77.​2

VL Multi-frame Image Storage - Trial (Retired)

VL​Multi​Frame​Image​Storage​Trial

SOP Class

PS3.4 (1998)

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​1

VL Endoscopic Image Storage

VL​Endoscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​1.​1

Video Endoscopic Image Storage

Video​Endoscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​2

VL Microscopic Image Storage

VL​Microscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​2.​1

Video Microscopic Image Storage

Video​Microscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​3

VL Slide-Coordinates Microscopic Image Storage

VL​Slide​Coordinates​Microscopic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​4

VL Photographic Image Storage

VL​Photographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​4.​1

Video Photographic Image Storage

Video​Photographic​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​1

Ophthalmic Photography 8 Bit Image Storage

Ophthalmic​Photography​8​Bit​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​2

Ophthalmic Photography 16 Bit Image Storage

Ophthalmic​Photography​16​Bit​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​3

Stereometric Relationship Storage

Stereometric​Relationship​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​4

Ophthalmic Tomography Image Storage

Ophthalmic​Tomography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​5

Wide Field Ophthalmic Photography Stereographic Projection Image Storage

Wide​Field​Ophthalmic​Photography​Stereographic​Projection​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​6

Wide Field Ophthalmic Photography 3D Coordinates Image Storage

Wide​Field​Ophthalmic​Photography​3D​Coordinates​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​7

Ophthalmic Optical Coherence Tomography En Face Image Storage

Ophthalmic​Optical​Coherence​Tomography​En​Face​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.1.​5.​8

Ophthalmic Optical Coherence Tomography B-scan Volume Analysis Storage

Ophthalmic​Optical​Coherence​Tomography​B​scan​Volume​Analysis​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​6

VL Whole Slide Microscopy Image Storage

VL​Whole​Slide​Microscopy​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.77.​1.​7

Dermoscopic Photography Image Storage

Dermoscopic​Photography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​1

Lensometry Measurements Storage

Lensometry​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​2

Autorefraction Measurements Storage

Autorefraction​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​3

Keratometry Measurements Storage

Keratometry​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​4

Subjective Refraction Measurements Storage

Subjective​Refraction​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​5

Visual Acuity Measurements Storage

Visual​Acuity​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​6

Spectacle Prescription Report Storage

Spectacle​Prescription​Report​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​7

Ophthalmic Axial Measurements Storage

Ophthalmic​Axial​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​78.​8

Intraocular Lens Calculations Storage

Intraocular​Lens​Calculations​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​79.​1

Macular Grid Thickness and Volume Report Storage

Macular​Grid​Thickness​And​Volume​Report​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​80.​1

Ophthalmic Visual Field Static Perimetry Measurements Storage

Ophthalmic​Visual​Field​Static​Perimetry​Measurements​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​81.​1

Ophthalmic Thickness Map Storage

Ophthalmic​Thickness​Map​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​82.​1

Corneal Topography Map Storage

Corneal​Topography​Map​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​1

Text SR Storage - Trial (Retired)

Text​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​2

Audio SR Storage - Trial (Retired)

Audio​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​3

Detail SR Storage - Trial (Retired)

Detail​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​4

Comprehensive SR Storage - Trial (Retired)

Comprehensive​SR​Storage​Trial

SOP Class

PS3.4 (2007)

1.2.840.10008.​5.​1.​4.​1.​1.​88.​11

Basic Text SR Storage

Basic​Text​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​22

Enhanced SR Storage

Enhanced​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​33

Comprehensive SR Storage

Comprehensive​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​34

Comprehensive 3D SR Storage

Comprehensive​3D​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​35

Extensible SR Storage

Extensible​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​40

Procedure Log Storage

Procedure​Log​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​50

Mammography CAD SR Storage

Mammography​CAD​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​59

Key Object Selection Document Storage

Key​Object​Selection​Document​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​65

Chest CAD SR Storage

Chest​CAD​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​67

X-Ray Radiation Dose SR Storage

X​Ray​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​68

Radiopharmaceutical Radiation Dose SR Storage

Radiopharmaceutical​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​69

Colon CAD SR Storage

Colon​CAD​SR​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​88.​70

Implantation Plan SR Storage

Implantation​Plan​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​71

Acquisition Context SR Storage

Acquisition​Context​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​72

Simplified Adult Echo SR Storage

Simplified​Adult​Echo​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​73

Patient Radiation Dose SR Storage

Patient​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​74

Planned Imaging Agent Administration SR Storage

Planned​Imaging​Agent​Administration​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​75

Performed Imaging Agent Administration SR Storage

Performed​Imaging​Agent​Administration​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​88.​76

Enhanced X-Ray Radiation Dose SR Storage

Enhanced​XRay​Radiation​Dose​SR​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​90.​1

Content Assessment Results Storage

Content​Assessment​Results​Storage

SOP Class

PS3.4

1.2.840.10008.5.​1.​4.​1.​1.​91.​1

Microscopy Bulk Simple Annotations Storage

Microscopy​Bulk​Simple​Annotations​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​1

Encapsulated PDF Storage

Encapsulated​PDF​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​2

Encapsulated CDA Storage

Encapsulated​CDA​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​3

Encapsulated STL Storage

Encapsulated​STL​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​4

Encapsulated OBJ Storage

Encapsulated​OBJ​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​104.​5

Encapsulated MTL Storage

Encapsulated​MTL​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​128

Positron Emission Tomography Image Storage

Positron​Emission​Tomography​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​128.​1

Legacy Converted Enhanced PET Image Storage

Legacy​Converted​Enhanced​PET​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​129

Standalone PET Curve Storage (Retired)

Standalone​PET​Curve​Storage

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.​1.​130

Enhanced PET Image Storage

Enhanced​PET​Image​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.​1.​131

Basic Structured Display Storage

Basic​Structured​Display​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.1

CT Defined Procedure Protocol Storage

CT​Defined​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.2

CT Performed Procedure Protocol Storage

CT​Performed​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.3

Protocol Approval Storage

Protocol​Approval​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.4

Protocol Approval Information Model - FIND

Protocol​Approval​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.5

Protocol Approval Information Model - MOVE

Protocol​Approval​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.6

Protocol Approval Information Model - GET

Protocol​Approval​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.7

XA Defined Procedure Protocol Storage

XA​Defined​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.1.200.8

XA Performed Procedure Protocol Storage

XA​Performed​Procedure​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​1

RT Image Storage

RT​Image​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​2

RT Dose Storage

RT​Dose​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​3

RT Structure Set Storage

RT​Structure​Set​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​4

RT Beams Treatment Record Storage

RT​Beams​Treatment​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​5

RT Plan Storage

RT​Plan​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​6

RT Brachy Treatment Record Storage

RT​Brachy​Treatment​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​7

RT Treatment Summary Record Storage

RT​Treatment​Summary​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​8

RT Ion Plan Storage

RT​Ion​Plan​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​9

RT Ion Beams Treatment Record Storage

RT​Ion​Beams​Treatment​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​10

RT Physician Intent Storage

RT​Physician​Intent​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​11

RT Segment Annotation Storage

RT​Segment​Annotation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​12

RT Radiation Set Storage

RT​Radiation​Set​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​13

C-Arm Photon-Electron Radiation Storage

C​Arm​Photon​Electron​Radiation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​14

Tomotherapeutic Radiation Storage

Tomotherapeutic​Radiation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​15

Robotic-Arm Radiation Storage

Robotic​Arm​Radiation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​16

RT Radiation Record Set Storage

RT​Radiation​Record​Set​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​17

RT Radiation Salvage Record Storage

RT​Radiation​Salvage​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​18

Tomotherapeutic Radiation Record Storage

Tomotherapeutic​Radiation​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​19

C-Arm Photon-Electron Radiation Record Storage

C​Arm​Photon​Electron​Radiation​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​20

Robotic Radiation Record Storage

Robotic​Radiation​Record​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​21

RT Radiation Set Delivery Instruction Storage

RT​Radiation​Set​Delivery​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​481.​22

RT Treatment Preparation Storage

RT​Treatment​Preparation​Storage

SOP Class

PS3.4

1.2.840.10008.​5.​1.​4.​1.​1.​501.​1

DICOS CT Image Storage

DICOS​CT​Image​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.501.​2.​1

DICOS Digital X-Ray Image Storage - For Presentation

DICOS​Digital​X​Ray​Image​​StorageFor​Presentation

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.501.​2.​2

DICOS Digital X-Ray Image Storage - For Processing

DICOS​Digital​X​Ray​Image​​StorageFor​Processing

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​3

DICOS Threat Detection Report Storage

DICOS​Threat​Detection​Report​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​4

DICOS 2D AIT Storage

DICOS​2D​AIT​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​5

DICOS 3D AIT Storage

DICOS​3D​AIT​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​501.​6

DICOS Quadrupole Resonance (QR) Storage

DICOS​Quadrupole​Resonance​Storage

SOP Class

DICOS

1.2.840.10008.​5.​1.​4.​1.​1.​601.​1

Eddy Current Image Storage

Eddy​Current​Image​Storage

SOP Class

DICONDE ASTM E2934

1.2.840.10008.​5.​1.​4.​1.​1.​601.​2

Eddy Current Multi-frame Image Storage

Eddy​Current​Multi​Frame​Image​Storage

SOP Class

DICONDE ASTM E2934

1.2.840.10008.5.1.4.1.2.​1.​1

Patient Root Query/Retrieve Information Model - FIND

Patient​Root​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​1.​2

Patient Root Query/Retrieve Information Model - MOVE

Patient​Root​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​1.​3

Patient Root Query/Retrieve Information Model - GET

Patient​Root​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​1

Study Root Query/Retrieve Information Model - FIND

Study​Root​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​2

Study Root Query/Retrieve Information Model - MOVE

Study​Root​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​2.​3

Study Root Query/Retrieve Information Model - GET

Study​Root​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​3.​1

Patient/Study Only Query/Retrieve Information Model - FIND (Retired)

Patient​​Study​Only​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.2.​3.​2

Patient/Study Only Query/Retrieve Information Model - MOVE (Retired)

Patient​Study​Only​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.2.​3.​3

Patient/Study Only Query/Retrieve Information Model - GET (Retired)

Patient​Study​Only​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4 (2004)

1.2.840.10008.5.1.4.1.2.​4.​2

Composite Instance Root Retrieve - MOVE

Composite​Instance​Root​Retrieve​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​4.​3

Composite Instance Root Retrieve - GET

Composite​Instance​Root​Retrieve​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.1.2.​5.​3

Composite Instance Retrieve Without Bulk Data - GET

Composite​Instance​Retrieve​Without​Bulk​Data​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.1

Defined Procedure Protocol Information Model - FIND

Defined​Procedure​Protocol​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.2

Defined Procedure Protocol Information Model - MOVE

Defined​Procedure​Protocol​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.20.3

Defined Procedure Protocol Information Model - GET

Defined​Procedure​Protocol​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​31

Modality Worklist Information Model - FIND

Modality​Worklist​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​32

General Purpose Worklist Management Meta SOP Class (Retired)

General​Purpose​Worklist​Management​Meta

Meta SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.4.​32.​1

General Purpose Worklist Information Model - FIND (Retired)

General​Purpose​Worklist​Information​ModelFind

SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.4.​32.​2

General Purpose Scheduled Procedure Step SOP Class (Retired)

General​Purpose​Scheduled​Procedure​Step

SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.4.​32.​3

General Purpose Performed Procedure Step SOP Class (Retired)

General​Purpose​Performed​Procedure​Step

SOP Class

PS3.4 (2011)

1.2.840.10008.5.1.​4.​33

Instance Availability Notification SOP Class

Instance​Availability​Notification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​1

RT Beams Delivery Instruction Storage - Trial (Retired)

RT​Beams​Delivery​Instruction​Storage​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​2

RT Conventional Machine Verification - Trial (Retired)

RT​Conventional​Machine​Verification​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​3

RT Ion Machine Verification - Trial (Retired)

RT​Ion​Machine​Verification​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​4

Unified Worklist and Procedure Step Service Class - Trial (Retired)

Unified​Worklist​And​Procedure​Step​Trial

Service Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​1

Unified Procedure Step - Push SOP Class - Trial (Retired)

Unified​Procedure​Step​Push​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​2

Unified Procedure Step - Watch SOP Class - Trial (Retired)

Unified​Procedure​Step​Watch​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​3

Unified Procedure Step - Pull SOP Class - Trial (Retired)

Unified​Procedure​Step​Pull​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.34.​4.​4

Unified Procedure Step - Event SOP Class - Trial (Retired)

Unified​Procedure​Step​Event​Trial

SOP Class

PS3.4 (2009)

1.2.840.10008.5.1.4.​34.​5

UPS Global Subscription SOP Instance

UPS​Global​Subscription​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.​34.​5.​1

UPS Filtered Global Subscription SOP Instance

UPS​Filtered​Global​Subscription​Instance

Well-known SOP Instance

PS3.4

1.2.840.10008.5.1.4.​34.​6

Unified Worklist and Procedure Step Service Class

Unified​Worklist​And​Procedure​Step

Service Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​1

Unified Procedure Step - Push SOP Class

Unified​Procedure​Step​Push

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​2

Unified Procedure Step - Watch SOP Class

Unified​Procedure​Step​Watch

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​3

Unified Procedure Step - Pull SOP Class

Unified​Procedure​Step​Pull

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​4

Unified Procedure Step - Event SOP Class

Unified​Procedure​Step​Event

SOP Class

PS3.4

1.2.840.10008.5.1.4.34.​6.​5

Unified Procedure Step - Query SOP Class

Unified​Procedure​Step​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​7

RT Beams Delivery Instruction Storage

RT​Beams​Delivery​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​8

RT Conventional Machine Verification

RT​Conventional​Machine​Verification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​9

RT Ion Machine Verification

RT​Ion​Machine​Verification

SOP Class

PS3.4

1.2.840.10008.5.1.4.​34.​10

RT Brachy Application Setup Delivery Instruction Storage

RT​Brachy​Application​Setup​Delivery​Instruction​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​1

General Relevant Patient Information Query

General​Relevant​Patient​Information​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​2

Breast Imaging Relevant Patient Information Query

Breast​Imaging​Relevant​Patient​Information​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​37.​3

Cardiac Relevant Patient Information Query

Cardiac​Relevant​Patient​Information​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​1

Hanging Protocol Storage

Hanging​Protocol​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​2

Hanging Protocol Information Model - FIND

Hanging​Protocol​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​3

Hanging Protocol Information Model - MOVE

Hanging​Protocol​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​38.​4

Hanging Protocol Information Model - GET

Hanging​Protocol​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​1

Color Palette Storage

Color​Palette​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​2

Color Palette Query/Retrieve Information Model - FIND

Color​Palette​Query​Retrieve​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​3

Color Palette Query/Retrieve Information Model - MOVE

Color​Palette​Query​Retrieve​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​39.​4

Color Palette Query/Retrieve Information Model - GET

Color​Palette​Query​Retrieve​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​41

Product Characteristics Query SOP Class

Product​Characteristics​Query

SOP Class

PS3.4

1.2.840.10008.5.1.​4.​42

Substance Approval Query SOP Class

Substance​Approval​Query

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​1

Generic Implant Template Storage

Generic​Implant​Template​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​2

Generic Implant Template Information Model - FIND

Generic​Implant​Template​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​3

Generic Implant Template Information Model - MOVE

Generic​Implant​Template​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​43.​4

Generic Implant Template Information Model - GET

Generic​Implant​Template​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​1

Implant Assembly Template Storage

Implant​Assembly​Template​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​2

Implant Assembly Template Information Model - FIND

Implant​Assembly​Template​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​3

Implant Assembly Template Information Model - MOVE

Implant​Assembly​Template​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​44.​4

Implant Assembly Template Information Model - GET

Implant​Assembly​Template​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​1

Implant Template Group Storage

Implant​Template​Group​Storage

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​2

Implant Template Group Information Model - FIND

Implant​Template​Group​Information​Model​Find

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​3

Implant Template Group Information Model - MOVE

Implant​Template​Group​Information​Model​Move

SOP Class

PS3.4

1.2.840.10008.5.1.4.​45.​4

Implant Template Group Information Model - GET

Implant​Template​Group​Information​Model​Get

SOP Class

PS3.4

1.2.840.10008.7.​1.​1

Native DICOM Model

Native​DICOM​Model

Application Hosting Model

PS3.19

1.2.840.10008.7.​1.​2

Abstract Multi-Dimensional Image Model

Abstract​Multi​Dimensional​Image​Model

Application Hosting Model

PS3.19

1.2.840.10008.8.​1.​1

DICOM Content Mapping Resource

DICOM​Content​Mapping​Resource

Mapping Resource

PS3.16

1.2.840.10008.10.1

Video Endoscopic Image Real-Time Communication

Video​Endoscopic​Image​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.10.2

Video Photographic Image Real-Time Communication

Video​Photographic​Image​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.10.3

Audio Waveform Real-Time Communication

Audio​Waveform​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.10.4

Rendition Selection Document Real-Time Communication

Rendition​Selection​Document​Real​Time​Communication

SOP Class

PS3.22

1.2.840.10008.15.0.​3.​1

dicom​Device​Name

dicom​Device​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​2

dicom​Description

dicom​Description

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​3

dicom​Manufacturer

dicom​Manufacturer

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​4

dicom​Manufacturer​Model​Name

dicom​Manufacturer​Model​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​5

dicom​Software​Version

dicom​Software​Version

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​6

dicom​Vendor​Data

dicom​Vendor​Data

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​7

dicom​AE​Title

dicom​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​8

dicom​Network​Connection​Reference

dicom​Network​Connection​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​9

dicom​Application​Cluster

dicom​Application​Cluster

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​10

dicom​Association​Initiator

dicom​Association​Initiator

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​11

dicom​Association​Acceptor

dicom​Association​Acceptor

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​12

dicom​Hostname

dicom​Hostname

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​13

dicom​Port

dicom​Port

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​14

dicom​SOP​Class

dicom​SOP​Class

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​15

dicom​Transfer​Role

dicom​Transfer​Role

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​16

dicom​Transfer​Syntax

dicom​Transfer​Syntax

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​17

dicom​Primary​Device​Type

dicom​Primary​Device​Type

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​18

dicom​Related​Device​Reference

dicom​Related​Device​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​19

dicom​Preferred​Called​AE​Title

dicom​Preferred​Called​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​20

dicom​TLS​Cyphersuite

dicom​TLS​Cyphersuite

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​21

dicom​Authorized​Node​Certificate​Reference

dicom​Authorized​Node​Certificate​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​22

dicom​This​Node​Certificate​Reference

dicom​This​Node​Certificate​Reference

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​23

dicom​Installed

dicom​Installed

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​24

dicom​Station​Name

dicom​Station​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​25

dicom​Device​Serial​Number

dicom​Device​Serial​Number

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​26

dicom​Institution​Name

dicom​Institution​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​27

dicom​Institution​Address

dicom​Institution​Address

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​28

dicom​Institution​Department​Name

dicom​Institution​Department​Name

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​29

dicom​Issuer​Of​Patient​ID

dicom​Issuer​Of​Patient​ID

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​30

dicom​Preferred​Calling​AE​Title

dicom​Preferred​Calling​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​3.​31

dicom​Supported​Character​Set

dicom​Supported​Character​Set

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​1

dicom​Configuration​Root

dicom​Configuration​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​2

dicom​Devices​Root

dicom​Devices​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​3

dicom​Unique​AE​Titles​Registry​Root

dicom​Unique​AE​Titles​Registry​Root

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​4

dicom​Device

dicom​Device

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​5

dicom​Network​AE

dicom​Network​AE

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​6

dicom​Network​Connection

dicom​Network​Connection

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​7

dicom​Unique​AE​Title

dicom​Unique​AE​Title

LDAP OID

PS3.15

1.2.840.10008.15.0.​4.​8

dicom​Transfer​Capability

dicom​Transfer​Capability

LDAP OID

PS3.15

1.2.840.10008.15.​1.​1

Universal Coordinated Time

UTC

Synchronization Frame of Reference

PS3.3


Table A-2 lists the UID values that are registered for Frames of Reference.

Table A-2. Well-known Frames of Reference

UID Value

UID Name

UID ​Keyword

Normative Reference

1.2.840.10008.1.4.​1.​1

Talairach Brain Atlas Frame of Reference

Talairach​Brain​Atlas

Talairach J. and Tournoux P. Co-Planar stereotactic atlas of the human brain. Stuttgart: Georg Thieme Verlag, 1988.

1.2.840.10008.1.4.​1.​2

SPM2 T1 Frame of Reference

SPM2​T1

http://​github.com/​spm/​spm2/​blob/​master/templates/T1.mnc

1.2.840.10008.1.4.​1.​3

SPM2 T2 Frame of Reference

SPM2​T2

http://​github.com/​spm/​spm2/​blob/​master/templates/T2.mnc

1.2.840.10008.1.4.​1.​4

SPM2 PD Frame of Reference

SPM2​PD

http://​github.com/​spm/​spm2/​blob/​master/templates/PD.mnc

1.2.840.10008.1.4.​1.​5

SPM2 EPI Frame of Reference

SPM2​EPI

http://​github.com/​spm/​spm2/​blob/​master/templates/EPI.mnc

1.2.840.10008.1.4.​1.​6

SPM2 FIL T1 Frame of Reference

SPM2​FILT1

http://​github.com/​spm/​spm2/​blob/​master/templates/filT1.mnc

1.2.840.10008.1.4.​1.​7

SPM2 PET Frame of Reference

SPM2​PET

http://​github.com/​spm/​spm2/​blob/​master/templates/PET.mnc

1.2.840.10008.1.4.​1.​8

SPM2 TRANSM Frame of Reference

SPM2​TRANSM

http://​github.com/​spm/​spm2/​blob/​master/templates/Transm.mnc

1.2.840.10008.1.4.​1.​9

SPM2 SPECT Frame of Reference

SPM2​SPECT

http://​github.com/​spm/​spm2/​blob/​master/templates/SPECT.mnc

1.2.840.10008.1.4.​1.​10

SPM2 GRAY Frame of Reference

SPM2​GRAY

http://​github.com/​spm/​spm2/​blob/​master/apriori/gray.mnc

1.2.840.10008.1.4.​1.​11

SPM2 WHITE Frame of Reference

SPM2​WHITE

http://​github.com/​spm/​spm2/​blob/​master/apriori/white.mnc

1.2.840.10008.1.4.​1.​12

SPM2 CSF Frame of Reference

SPM2​CSF

http://​github.com/​spm/​spm2/​blob/​master/apriori/csf.mnc

1.2.840.10008.1.4.​1.​13

SPM2 BRAINMASK Frame of Reference

SPM2​BRAIN​MASK

http://​github.com/​spm/​spm2/​blob/​master/apriori/brainmask.mnc

1.2.840.10008.1.4.​1.​14

SPM2 AVG305T1 Frame of Reference

SPM2AVG305T1

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg305T1.mnc

1.2.840.10008.1.4.​1.​15

SPM2 AVG152T1 Frame of Reference

SPM2​AVG152T1

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T1.mnc

1.2.840.10008.1.4.​1.​16

SPM2 AVG152T2 Frame of Reference

SPM2​AVG152T2

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152T2.mnc

1.2.840.10008.1.4.​1.​17

SPM2 AVG152PD Frame of Reference

SPM2​AVG152PD

http://​github.com/​spm/​spm2/​blob/​master/canonical/avg152PD.mnc

1.2.840.10008.1.4.​1.​18

SPM2 SINGLESUBJT1 Frame of Reference

SPM2​SINGLESUBJT1

http://​github.com/​spm/​spm2/​blob/​master/canonical/single_subj_T1.mnc

1.2.840.10008.1.4.​2.​1

ICBM 452 T1 Frame of Reference

ICBM​452T1

ICBM452 T1 Atlas http://resource.loni.usc.edu/​atlasfiles/​ICBM_452_T1_Atlas_Affine_Transformations.zip

1.2.840.10008.1.4.​2.​2

ICBM Single Subject MRI Frame of Reference

ICBM​Single​Subject​MRI

ICBM Single Subject MRI Anatomical Template http://resource.loni.usc.edu/​atlasfiles/​ICBM_Single_Subject_MRI_Anatomical_Template.zip

1.2.840.10008.1.4.3.1

IEC 61217 Fixed Coordinate System Frame of Reference

IEC​61217​Fixed​Coordinate​System

Fixed coordinate system ("f") of [IEC 61217] and Section C.36.12.2.1 “IEC 61217 Fixed Reference System Frame of Reference” in PS3.3

1.2.840.10008.1.4.3.2

Standard Robotic-Arm Coordinate System Frame of Reference

Standard​Robotic​Arm​Coordinate​System

See Section C.36.12.2.2 “Standard Robotic-Arm Coordinate System Frame of Reference” in PS3.3 .

1.2.840.10008.1.4.4.1

SRI24 Frame of Reference

SRI24

http://​www.nitrc.org/projects/​sri24/

1.2.840.10008.1.4.​5.1

Colin27 Frame of Reference

Colin27

http://​www.bic.mni.mcgill.ca/​ServicesAtlases/​Colin27

1.2.840.10008.1.4.​6.1

LPBA40/AIR Frame of Reference

LPBA40AIR

http://​resource.loni.usc.edu/​atlasfiles/​LPBA40_AIR_Atlas_NIFTI_format.zip

1.2.840.10008.1.4.​6.2

LPBA40/FLIRT Frame of Reference

LPBA40FLIRT

http://​resource.loni.usc.edu/​atlasfiles/​LPBA40_FLIRT_Atlas_NIFTI_format.zip

1.2.840.10008.1.4.​6.3

LPBA40/SPM5 Frame of Reference

LPBA40SPM5

http://​resource.loni.usc.edu/​atlasfiles/​LPBA40_SPM5_atlas_NIFTI_format.zip


SPM2 (Statistical Parametric Mapping) templates are available at http://github.com/spm/spm2/, and they are described at https://github.com/spm/spm2/blob/master/spm_templates.man.

ICBM templates are available at http://resource.loni.usc.edu/resources/atlases-downloads/ and http://bmap.ucla.edu/portfolio/atlases.

Table A-3 lists the Context Groups and their UID values. For retired Context Groups, the edition of the Standard in parentheses is the edition in which the item last appeared before it was retired.

Table A-3. Context Group UID Values

Context UID

Context Identifier

Context Group Name

Comment

1.2.840.10008.6.​1.​1

CID 2

Anatomic Modifier

1.2.840.10008.6.​1.​2

CID 4

Anatomic Region

1.2.840.10008.6.​1.​3

CID 5

Transducer Approach

1.2.840.10008.6.​1.​4

CID 6

Transducer Orientation

1.2.840.10008.6.​1.​5

CID 7

Ultrasound Beam Path

1.2.840.10008.6.​1.​6

CID 8

Angiographic Interventional Devices

1.2.840.10008.6.​1.​7

CID 9

Image Guided Therapeutic Procedures

1.2.840.10008.6.​1.​8

CID 10

Interventional Drug

1.2.840.10008.6.​1.​9

CID 11

Route of Administration

1.2.840.10008.6.​1.​10

CID 12

Radiographic Contrast Agent

1.2.840.10008.6.​1.​11

CID 13

Radiographic Contrast Agent Ingredient

1.2.840.10008.6.​1.​12

CID 18

Isotopes in Radiopharmaceuticals

1.2.840.10008.6.​1.​13

CID 19

Patient Orientation

1.2.840.10008.6.​1.​14

CID 20

Patient Orientation Modifier

1.2.840.10008.6.​1.​15

CID 21

Patient Equipment Relationship

1.2.840.10008.6.​1.​16

CID 23

Cranio-Caudad Angulation

1.2.840.10008.6.​1.​17

CID 25

Radiopharmaceuticals

1.2.840.10008.6.​1.​18

CID 26

Nuclear Medicine Projections

1.2.840.10008.6.​1.​19

CID 29

Acquisition Modality

1.2.840.10008.6.​1.​20

CID 30

DICOM Devices

1.2.840.10008.6.​1.​21

CID 31

Abstract Priors

1.2.840.10008.6.​1.​22

CID 42

Numeric Value Qualifier

1.2.840.10008.6.​1.​23

CID 82

Units of Measurement

1.2.840.10008.6.​1.​24

CID 83

Units for Real World Value Mapping

1.2.840.10008.6.​1.​25

CID 220

Level of Significance

1.2.840.10008.6.​1.​26

CID 221

Measurement Range Concepts

1.2.840.10008.6.​1.​27

CID 222

Normality Codes

1.2.840.10008.6.​1.​28

CID 223

Normal Range Values

1.2.840.10008.6.​1.​29

CID 224

Selection Method

1.2.840.10008.6.​1.​30

CID 225

Measurement Uncertainty Concepts

1.2.840.10008.6.​1.​31

CID 226

Population Statistical Descriptors

1.2.840.10008.6.​1.​32

CID 227

Sample Statistical Descriptors

1.2.840.10008.6.​1.​33

CID 228

Equation or Table

1.2.840.10008.6.​1.​34

CID 230

Yes-No

1.2.840.10008.6.​1.​35

CID 240

Present-Absent

1.2.840.10008.6.​1.​36

CID 242

Normal-Abnormal

1.2.840.10008.6.​1.​37

CID 244

Laterality

1.2.840.10008.6.​1.​38

CID 250

Positive-Negative

1.2.840.10008.6.​1.​39

CID 251

Severity of Complication

1.2.840.10008.6.​1.​40

CID 270

Observer Type

1.2.840.10008.6.​1.​41

CID 271

Observation Subject Class

1.2.840.10008.6.​1.​42

CID 3000

Audio Channel Source

1.2.840.10008.6.​1.​43

CID 3001

ECG Leads

1.2.840.10008.6.​1.​44

CID 3003

Hemodynamic Waveform Sources

1.2.840.10008.6.​1.​45

CID 3010

Cardiovascular Anatomic Locations

1.2.840.10008.6.​1.​46

CID 3011

Electrophysiology Anatomic Locations

1.2.840.10008.6.​1.​47

CID 3014

Coronary Artery Segments

1.2.840.10008.6.​1.​48

CID 3015

Coronary Arteries

1.2.840.10008.6.​1.​49

CID 3019

Cardiovascular Anatomic Location Modifiers

1.2.840.10008.6.​1.​50

CID 3082

Cardiology Units of Measurement (Retired)

RET (2011)

1.2.840.10008.6.​1.​51

CID 3090

Time Synchronization Channel Types

1.2.840.10008.6.​1.​52

CID 3101

Cardiac Procedural State Values

1.2.840.10008.6.​1.​53

CID 3240

Electrophysiology Measurement Functions and Techniques

1.2.840.10008.6.​1.​54

CID 3241

Hemodynamic Measurement Techniques

1.2.840.10008.6.​1.​55

CID 3250

Catheterization Procedure Phase

1.2.840.10008.6.​1.​56

CID 3254

Electrophysiology Procedure Phase

1.2.840.10008.6.​1.​57

CID 3261

Stress Protocols

1.2.840.10008.6.​1.​58

CID 3262

ECG Patient State Values

1.2.840.10008.6.​1.​59

CID 3263

Electrode Placement Values

1.2.840.10008.6.​1.​60

CID 3264

XYZ Electrode Placement Values (Retired)

RET (2013)

1.2.840.10008.6.​1.​61

CID 3271

Hemodynamic Physiological Challenges

1.2.840.10008.6.​1.​62

CID 3335

ECG Annotations

1.2.840.10008.6.​1.​63

CID 3337

Hemodynamic Annotations

1.2.840.10008.6.​1.​64

CID 3339

Electrophysiology Annotations

1.2.840.10008.6.​1.​65

CID 3400

Procedure Log Titles

1.2.840.10008.6.​1.​66

CID 3401

Types of Log Notes

1.2.840.10008.6.​1.​67

CID 3402

Patient Status and Events

1.2.840.10008.6.​1.​68

CID 3403

Percutaneous Entry

1.2.840.10008.6.​1.​69

CID 3404

Staff Actions

1.2.840.10008.6.​1.​70

CID 3405

Procedure Action Values

1.2.840.10008.6.​1.​71

CID 3406

Non-coronary Transcatheter Interventions

1.2.840.10008.6.​1.​72

CID 3407

Purpose of Reference to Object

1.2.840.10008.6.​1.​73

CID 3408

Actions With Consumables

1.2.840.10008.6.​1.​74

CID 3409

Administration of Drugs/Contrast

1.2.840.10008.6.​1.​75

CID 3410

Numeric Parameters of Drugs/Contrast

1.2.840.10008.6.​1.​76

CID 3411

Intracoronary Devices

1.2.840.10008.6.​1.​77

CID 3412

Intervention Actions and Status

1.2.840.10008.6.​1.​78

CID 3413

Adverse Outcomes

1.2.840.10008.6.​1.​79

CID 3414

Procedure Urgency

1.2.840.10008.6.​1.​80

CID 3415

Cardiac Rhythms

1.2.840.10008.6.​1.​81

CID 3416

Respiration Rhythms

1.2.840.10008.6.​1.​82

CID 3418

Lesion Risk

1.2.840.10008.6.​1.​83

CID 3419

Findings Titles

1.2.840.10008.6.​1.​84

CID 3421

Procedure Action

1.2.840.10008.6.​1.​85

CID 3422

Device Use Actions

1.2.840.10008.6.​1.​86

CID 3423

Numeric Device Characteristics

1.2.840.10008.6.​1.​87

CID 3425

Intervention Parameters

1.2.840.10008.6.​1.​88

CID 3426

Consumables Parameters

1.2.840.10008.6.​1.​89

CID 3427

Equipment Events

1.2.840.10008.6.​1.​90

CID 3428

Imaging Procedures

1.2.840.10008.6.​1.​91

CID 3429

Catheterization Devices

1.2.840.10008.6.​1.​92

CID 3430

DateTime Qualifiers

1.2.840.10008.6.​1.​93

CID 3440

Peripheral Pulse Locations

1.2.840.10008.6.​1.​94

CID 3441

Patient Assessments

1.2.840.10008.6.​1.​95

CID 3442

Peripheral Pulse Methods

1.2.840.10008.6.​1.​96

CID 3446

Skin Condition

1.2.840.10008.6.​1.​97

CID 3448

Airway Assessment

1.2.840.10008.6.​1.​98

CID 3451

Calibration Objects

1.2.840.10008.6.​1.​99

CID 3452

Calibration Methods

1.2.840.10008.6.​1.​100

CID 3453

Cardiac Volume Methods

1.2.840.10008.6.​1.​101

CID 3455

Index Methods

1.2.840.10008.6.​1.​102

CID 3456

Sub-segment Methods

1.2.840.10008.6.​1.​103

CID 3458

Contour Realignment

1.2.840.10008.6.​1.​104

CID 3460

Circumferential Extent

1.2.840.10008.6.​1.​105

CID 3461

Regional Extent

1.2.840.10008.6.​1.​106

CID 3462

Chamber Identification

1.2.840.10008.6.​1.​107

CID 3465

QA Reference Methods

1.2.840.10008.6.​1.​108

CID 3466

Plane Identification

1.2.840.10008.6.​1.​109

CID 3467

Ejection Fraction

1.2.840.10008.6.​1.​110

CID 3468

ED Volume

1.2.840.10008.6.​1.​111

CID 3469

ES Volume

1.2.840.10008.6.​1.​112

CID 3470

Vessel Lumen Cross-sectional Area Calculation Methods

1.2.840.10008.6.​1.​113

CID 3471

Estimated Volumes

1.2.840.10008.6.​1.​114

CID 3472

Cardiac Contraction Phase

1.2.840.10008.6.​1.​115

CID 3480

IVUS Procedure Phases

1.2.840.10008.6.​1.​116

CID 3481

IVUS Distance Measurements

1.2.840.10008.6.​1.​117

CID 3482

IVUS Area Measurements

1.2.840.10008.6.​1.​118

CID 3483

IVUS Longitudinal Measurements

1.2.840.10008.6.​1.​119

CID 3484

IVUS Indices and Ratios

1.2.840.10008.6.​1.​120

CID 3485

IVUS Volume Measurements

1.2.840.10008.6.​1.​121

CID 3486

Vascular Measurement Sites

1.2.840.10008.6.​1.​122

CID 3487

Intravascular Volumetric Regions

1.2.840.10008.6.​1.​123

CID 3488

Min/Max/Mean

1.2.840.10008.6.​1.​124

CID 3489

Calcium Distribution

1.2.840.10008.6.​1.​125

CID 3491

IVUS Lesion Morphologies

1.2.840.10008.6.​1.​126

CID 3492

Vascular Dissection Classifications

1.2.840.10008.6.​1.​127

CID 3493

IVUS Relative Stenosis Severities

1.2.840.10008.6.​1.​128

CID 3494

IVUS Non Morphological Findings

1.2.840.10008.6.​1.​129

CID 3495

IVUS Plaque Composition

1.2.840.10008.6.​1.​130

CID 3496

IVUS Fiducial Points

1.2.840.10008.6.​1.​131

CID 3497

IVUS Arterial Morphology

1.2.840.10008.6.​1.​132

CID 3500

Pressure Units

1.2.840.10008.6.​1.​133

CID 3502

Hemodynamic Resistance Units

1.2.840.10008.6.​1.​134

CID 3503

Indexed Hemodynamic Resistance Units

1.2.840.10008.6.​1.​135

CID 3510

Catheter Size Units

1.2.840.10008.6.​1.​136

CID 3515

Specimen Collection

1.2.840.10008.6.​1.​137

CID 3520

Blood Source Type

1.2.840.10008.6.​1.​138

CID 3524

Blood Gas Pressures

1.2.840.10008.6.​1.​139

CID 3525

Blood Gas Content

1.2.840.10008.6.​1.​140

CID 3526

Blood Gas Saturation

1.2.840.10008.6.​1.​141

CID 3527

Blood Base Excess

1.2.840.10008.6.​1.​142

CID 3528

Blood pH

1.2.840.10008.6.​1.​143

CID 3529

Arterial / Venous Content

1.2.840.10008.6.​1.​144

CID 3530

Oxygen Administration Actions

1.2.840.10008.6.​1.​145

CID 3531

Oxygen Administration

1.2.840.10008.6.​1.​146

CID 3550

Circulatory Support Actions

1.2.840.10008.6.​1.​147

CID 3551

Ventilation Actions

1.2.840.10008.6.​1.​148

CID 3552

Pacing Actions

1.2.840.10008.6.​1.​149

CID 3553

Circulatory Support

1.2.840.10008.6.​1.​150

CID 3554

Ventilation

1.2.840.10008.6.​1.​151

CID 3555

Pacing

1.2.840.10008.6.​1.​152

CID 3560

Blood Pressure Methods

1.2.840.10008.6.​1.​153

CID 3600

Relative Times

1.2.840.10008.6.​1.​154

CID 3602

Hemodynamic Patient State

1.2.840.10008.6.​1.​155

CID 3604

Arterial Lesion Locations

1.2.840.10008.6.​1.​156

CID 3606

Arterial Source Locations

1.2.840.10008.6.​1.​157

CID 3607

Venous Source Locations

1.2.840.10008.6.​1.​158

CID 3608

Atrial Source Locations

1.2.840.10008.6.​1.​159

CID 3609

Ventricular Source Locations

1.2.840.10008.6.​1.​160

CID 3610

Gradient Source Locations

1.2.840.10008.6.​1.​161

CID 3611

Pressure Measurements

1.2.840.10008.6.​1.​162

CID 3612

Blood Velocity Measurements

1.2.840.10008.6.​1.​163

CID 3613

Hemodynamic Time Measurements

1.2.840.10008.6.​1.​164

CID 3614

Valve Areas, Non-mitral

1.2.840.10008.6.​1.​165

CID 3615

Valve Areas

1.2.840.10008.6.​1.​166

CID 3616

Hemodynamic Period Measurements

1.2.840.10008.6.​1.​167

CID 3617

Valve Flows

1.2.840.10008.6.​1.​168

CID 3618

Hemodynamic Flows

1.2.840.10008.6.​1.​169

CID 3619

Hemodynamic Resistance Measurements

1.2.840.10008.6.​1.​170

CID 3620

Hemodynamic Ratios

1.2.840.10008.6.​1.​171

CID 3621

Fractional Flow Reserve

1.2.840.10008.6.​1.​172

CID 3627

Measurement Type

1.2.840.10008.6.​1.​173

CID 3628

Cardiac Output Methods

1.2.840.10008.6.​1.​174

CID 3629

Procedure Intent

1.2.840.10008.6.​1.​175

CID 3630

Cardiovascular Anatomic Locations

1.2.840.10008.6.​1.​176

CID 3640

Hypertension

1.2.840.10008.6.​1.​177

CID 3641

Hemodynamic Assessments

1.2.840.10008.6.​1.​178

CID 3642

Degree Findings

1.2.840.10008.6.​1.​179

CID 3651

Hemodynamic Measurement Phase

1.2.840.10008.6.​1.​180

CID 3663

Body Surface Area Equations

1.2.840.10008.6.​1.​181

CID 3664

Oxygen Consumption Equations and Tables

1.2.840.10008.6.​1.​182

CID 3666

P50 Equations

1.2.840.10008.6.​1.​183

CID 3667

Framingham Scores

1.2.840.10008.6.​1.​184

CID 3668

Framingham Tables

1.2.840.10008.6.​1.​185

CID 3670

ECG Procedure Types

1.2.840.10008.6.​1.​186

CID 3671

Reason for ECG Exam

1.2.840.10008.6.​1.​187

CID 3672

Pacemakers

1.2.840.10008.6.​1.​188

CID 3673

Diagnosis (Retired)

RET (2013)

1.2.840.10008.6.​1.​189

CID 3675

Other Filters (Retired)

RET (2013)

1.2.840.10008.6.​1.​190

CID 3676

Lead Measurement Technique

1.2.840.10008.6.​1.​191

CID 3677

Summary Codes ECG

1.2.840.10008.6.​1.​192

CID 3678

QT Correction Algorithms

1.2.840.10008.6.​1.​193

CID 3679

ECG Morphology Descriptions (Retired)

RET (2013)

1.2.840.10008.6.​1.​194

CID 3680

ECG Lead Noise Descriptions

1.2.840.10008.6.​1.​195

CID 3681

ECG Lead Noise Modifiers (Retired)

1.2.840.10008.6.​1.​196

CID 3682

Probability (Retired)

RET (2013)

1.2.840.10008.6.​1.​197

CID 3683

Modifiers (Retired)

RET (2013)

1.2.840.10008.6.​1.​198

CID 3684

Trend (Retired)

RET (2013)

1.2.840.10008.6.​1.​199

CID 3685

Conjunctive Terms (Retired)

RET (2013)

1.2.840.10008.6.​1.​200

CID 3686

ECG Interpretive Statements (Retired)

RET (2013)

1.2.840.10008.6.​1.​201

CID 3687

Electrophysiology Waveform Durations

1.2.840.10008.6.​1.​202

CID 3688

Electrophysiology Waveform Voltages

1.2.840.10008.6.​1.​203

CID 3700

Cath Diagnosis

1.2.840.10008.6.​1.​204

CID 3701

Cardiac Valves and Tracts

1.2.840.10008.6.​1.​205

CID 3703

Wall Motion

1.2.840.10008.6.​1.​206

CID 3704

Myocardium Wall Morphology Findings

1.2.840.10008.6.​1.​207

CID 3705

Chamber Size

1.2.840.10008.6.​1.​208

CID 3706

Overall Contractility

1.2.840.10008.6.​1.​209

CID 3707

VSD Description

1.2.840.10008.6.​1.​210

CID 3709

Aortic Root Description

1.2.840.10008.6.​1.​211

CID 3710

Coronary Dominance

1.2.840.10008.6.​1.​212

CID 3711

Valvular Abnormalities

1.2.840.10008.6.​1.​213

CID 3712

Vessel Descriptors

1.2.840.10008.6.​1.​214

CID 3713

TIMI Flow Characteristics

1.2.840.10008.6.​1.​215

CID 3714

Thrombus

1.2.840.10008.6.​1.​216

CID 3715

Lesion Margin

1.2.840.10008.6.​1.​217

CID 3716

Severity

1.2.840.10008.6.​1.​218

CID 3717

Left Ventricle Myocardial Wall 17 Segments

1.2.840.10008.6.​1.​219

CID 3718

Myocardial Wall Segments in Projection

1.2.840.10008.6.​1.​220

CID 3719

Canadian Clinical Classification

1.2.840.10008.6.​1.​221

CID 3720

Cardiac History Dates (Retired)

RET (2007)

1.2.840.10008.6.​1.​222

CID 3721

Cardiovascular Surgeries

1.2.840.10008.6.​1.​223

CID 3722

Diabetic Therapy

1.2.840.10008.6.​1.​224

CID 3723

MI Types

1.2.840.10008.6.​1.​225

CID 3724

Smoking History

1.2.840.10008.6.​1.​226

CID 3726

Indications for Coronary Intervention

1.2.840.10008.6.​1.​227

CID 3727

Indications for Catheterization

1.2.840.10008.6.​1.​228

CID 3728

Cath Findings

1.2.840.10008.6.​1.​229

CID 3729

Admission Status

1.2.840.10008.6.​1.​230

CID 3730

Insurance Payor

1.2.840.10008.6.​1.​231

CID 3733

Primary Cause of Death

1.2.840.10008.6.​1.​232

CID 3735

Acute Coronary Syndrome Time Period

1.2.840.10008.6.​1.​233

CID 3736

NYHA Classification

1.2.840.10008.6.​1.​234

CID 3737

Non-invasive Test - Ischemia

1.2.840.10008.6.​1.​235

CID 3738

Pre-Cath Angina Type

1.2.840.10008.6.​1.​236

CID 3739

Cath Procedure Type

1.2.840.10008.6.​1.​237

CID 3740

Thrombolytic Administration

1.2.840.10008.6.​1.​238

CID 3741

Medication Administration, Lab Visit

1.2.840.10008.6.​1.​239

CID 3742

Medication Administration, PCI

1.2.840.10008.6.​1.​240

CID 3743

Clopidogrel/Ticlopidine Administration

1.2.840.10008.6.​1.​241

CID 3744

EF Testing Method

1.2.840.10008.6.​1.​242

CID 3745

Calculation Method

1.2.840.10008.6.​1.​243

CID 3746

Percutaneous Entry Site

1.2.840.10008.6.​1.​244

CID 3747

Percutaneous Closure

1.2.840.10008.6.​1.​245

CID 3748

Angiographic EF Testing Method

1.2.840.10008.6.​1.​246

CID 3749

PCI Procedure Result

1.2.840.10008.6.​1.​247

CID 3750

Previously Dilated Lesion

1.2.840.10008.6.​1.​248

CID 3752

Guidewire Crossing

1.2.840.10008.6.​1.​249

CID 3754

Vascular Complications

1.2.840.10008.6.​1.​250

CID 3755

Cath Complications

1.2.840.10008.6.​1.​251

CID 3756

Cardiac Patient Risk Factors

1.2.840.10008.6.​1.​252

CID 3757

Cardiac Diagnostic Procedures

1.2.840.10008.6.​1.​253

CID 3758

Cardiovascular Family History

1.2.840.10008.6.​1.​254

CID 3760

Hypertension Therapy

1.2.840.10008.6.​1.​255

CID 3761

Antilipemic Agents

1.2.840.10008.6.​1.​256

CID 3762

Antiarrhythmic Agents

1.2.840.10008.6.​1.​257

CID 3764

Myocardial Infarction Therapies

1.2.840.10008.6.​1.​258

CID 3769

Concern Types

1.2.840.10008.6.​1.​259

CID 3770

Problem Status

1.2.840.10008.6.​1.​260

CID 3772

Health Status

1.2.840.10008.6.​1.​261

CID 3773

Use Status

1.2.840.10008.6.​1.​262

CID 3774

Social History

1.2.840.10008.6.​1.​263

CID 3777

Implanted Devices

1.2.840.10008.6.​1.​264