DICOM PS3.3 2020a - Information Object Definitions

10.26 Attribute Value Macro

Table 10.26-1 includes an Attribute to store a value of a specified VR.

Table 10.26-1. Attribute Value Macro Attributes

Attribute Name

Tag

Type

Attribute Description

Selector AE Value

(0072,005E)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is AE.

Selector AS Value

(0072,005F)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is AS.

Selector AT Value

(0072,0060)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is AT.

Selector CS Value

(0072,0062)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is CS.

Selector DA Value

(0072,0061)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is DA.

See Note 2.

Selector DS Value

(0072,0072)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is DS. See Note 1 and Note 2.

Selector DT Value

(0072,0063)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is DT.

See Note 1 and Note 2.

Selector FD Value

(0072,0074)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is FD.

See Note 2.

Selector FL Value

(0072,0076)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is FL.

See Note 2.

Selector IS Value

(0072,0064)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is IS.

Selector LO Value

(0072,0066)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is LO.

Selector LT Value

(0072,0068)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is LT.

Selector OB Value

(0072,0065)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is OB.

Selector OD Value

(0072,0073)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is OD.

Selector OF Value

(0072,0067)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is OF.

Selector OL Value

(0072,0075)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is OL.

Selector OW Value

(0072,0069)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is OW.

Selector PN Value

(0072,006A)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is PN.

Selector SH Value

(0072,006C)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is SH.

Selector SL Value

(0072,007C)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is SL.

Selector SS Value

(0072,007E)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is SS.

Selector ST Value

(0072,006E)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is ST.

Selector TM Value

(0072,006B)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is TM.

See Note 1 and Note 2.

Selector UC Value

(0072,006F)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is UC.

Selector UI Value

(0072,007F)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is UI.

Selector UL Value

(0072,0078)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is UL.

Selector UN Value

(0072,006D)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is UN.

Selector UR Value

(0072,0071)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is UR.

Selector US Value

(0072,007A)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is US.

Selector UT Value

(0072,0070)

1C

The value of the Attribute identified by Selector Attribute (0072,0026).

Required if Selector Attribute VR (0072,0050) is present and the value is UT.

Selector Code Sequence Value

(0072,0080)

1C

The value(s) of the Attribute identified by Selector Attribute (0072,0026). One or more Items shall be included in this Sequence. See Section C.23.4.2.1.2.

Required if Selector Attribute VR (0072,0050) is present and the value is SQ and the Attribute referenced by the Selector Attribute (0072,0026) is a Code Sequence.

>Include Table 8.8-1 “Code Sequence Macro Attributes”

No Baseline CID is defined.


Note

  1. For string Value Representations, the meaning of the Value in the Standard shall be used, not the literal string. E.g. "1.0E+3" equals "1000" and "1000.0".

  2. Some leniency will be required by the application in precision when matching this selector value to an Attribute value.

DICOM PS3.3 2020a - Information Object Definitions