DICOM PS3.4 2017d - Service Class Specifications

CC.2.8.4 Status Codes

Table CC.2.8-2 defines the status code values that might be returned in a C-FIND response. Fields related to status code values are defined in PS3.7.

Table CC.2.8-2. C-FIND Response Status Values

Service Status

Further Meaning

Status Codes

Related Fields

Failure

Refused: Out of Resources

A700

(0000,0902)

Identifier Does Not Match SOP Class

A900

(0000,0901)

(0000,0902)

SOP Class not Supported

0122

Unable to process

(any value C000 through CFFF as assigned by the implementation)

(0000,0901)

(0000,0902)

Cancel

Matching terminated due to Cancel request

FE00

None

Success

Matching is complete - No final Identifier is supplied.

0000

None

Pending

Matches are continuing - Current Match is supplied and any Optional Keys were supported in the same manner as Required Keys.

FF00

Identifier

Matches are continuing - Warning that one or more Optional Keys were not supported for existence for this Identifier.

FF01

Identifier


Note

Status Codes are returned in DIMSE response messages (see PS3.7). The code values stated in column "Status Codes" are returned in Status Command Element (0000,0900).